Unspecified Domestic Hot Water

Domestic Hot Water

Manifold with 8 connections

Unspecified

Domestic Hot Water

Manifold with 8 connections

EMCS compliant

.RFA

Manifold

Unspecified

Descargar
Unspecified Domestic Cold Water

Domestic Cold Water

Manifold with 8 connections

Unspecified

Domestic Cold Water

Manifold with 8 connections

EMCS compliant

.RFA

Manifold

Unspecified

Descargar
Mitsubishi Heavy Industries FDC -KXZEN1/KXZES1

FDC -KXZEN1/KXZES1

Micro KXZ Heat pump VRF outdoor Unit -Connect up to 10 indoor units/up to 150% capacity. -High efficiency with COP (in cooling) up to 4.44 -These units employs DC inverter compressors ONLY. -Total piping length up to 100m and a maximum pipe run of 70m.

Mitsubishi Heavy Industries

FDC -KXZEN1/KXZES1

Micro KXZ Heat pump VRF outdoor Unit -Connect up to 10 indoor units/up to 150% capacity. -High efficiency with COP (in cooling) up to 4.44 -These units employs DC inverter compressors ONLY. -Total piping length up to 100m and a maximum pipe run of 70m.

EMCS compliant

.DWG .RFA .IFC

Bomba de calor

Mitsubishi Heavy Industries

Descargar
Mitsubishi Heavy Industries FDTS-KXZE6F

FDTS-KXZE6F

Ceiling Cassette -1way- indoor unit -Individual flap control system -Compact design -Drain can be discharged upward by 600mm -Wireless remote control is an option

Mitsubishi Heavy Industries

FDTS-KXZE6F

Ceiling Cassette -1way- indoor unit -Individual flap control system -Compact design -Drain can be discharged upward by 600mm -Wireless remote control is an option

EMCS compliant

.DWG .RFA .IFC

Unidad de aire acondicionado

Mitsubishi Heavy Industries

Descargar
Mitsubishi Heavy Industries PFD

PFD

PFD refrigerant flow branch control. -Easy installation, New PFD design means the connection of the indoor unit liquid pipe is made directly to the liquid line - bypassing the PFD. This means (x2) less pipe connections per indoor unit, reducing installation time and cost. -Optional PFD box extension cable that has a connector at ends makes it possible to separate the indoor unit and PFD box further, enable the PFD box to be located away from the indoor unit help reducing the influence of sound caused by PFD box and refrigerant flow.

Mitsubishi Heavy Industries

PFD

PFD refrigerant flow branch control. -Easy installation, New PFD design means the connection of the indoor unit liquid pipe is made directly to the liquid line - bypassing the PFD. This means (x2) less pipe connections per indoor unit, reducing installation time and cost. -Optional PFD box extension cable that has a connector at ends makes it possible to separate the indoor unit and PFD box further, enable the PFD box to be located away from the indoor unit help reducing the influence of sound caused by PFD box and refrigerant flow.

EMCS compliant

.DWG .RFA .IFC

Unidad de control para calefacción y aire acondicionado

Mitsubishi Heavy Industries

Descargar
Mitsubishi Heavy Industries RC-EX3

RC-EX3

Remote Controller -Wired Remote Controller with Easy touch and Easy view with full dot Liquid Crystal display -LCD panel with light tap operation -Simple interface with only three buttons -Multi language display (12 languages)

Mitsubishi Heavy Industries

RC-EX3

Remote Controller -Wired Remote Controller with Easy touch and Easy view with full dot Liquid Crystal display -LCD panel with light tap operation -Simple interface with only three buttons -Multi language display (12 languages)

EMCS compliant

.DWG .RFA .IFC

Unidad de control para calefacción y aire acondicionado

Mitsubishi Heavy Industries

Descargar
Mitsubishi Heavy Industries RCH-E3

RCH-E3

Simple Remote Controller -Considering specialized usage in hotel rooms -control buttons are limited only to minimum required functions -It can control up to 16 units individually, with pressing the AIR CON No. button. -Auto restart allows starting the air conditioner automatically when power supply is restored after power failure or by turning on the power switch.

Mitsubishi Heavy Industries

RCH-E3

Simple Remote Controller -Considering specialized usage in hotel rooms -control buttons are limited only to minimum required functions -It can control up to 16 units individually, with pressing the AIR CON No. button. -Auto restart allows starting the air conditioner automatically when power supply is restored after power failure or by turning on the power switch.

EMCS compliant

.DWG .RFA .IFC

Unidad de control para calefacción y aire acondicionado

Mitsubishi Heavy Industries

Descargar
Mitsubishi Heavy Industries FDK-KXZE1

FDK-KXZE1

Wall mounted indoor unit -Stylishly designed with rounded contours that fit beautifully into any of Europe’s diverse interior settings -Flap control system -The air flow design that's proven to minimise resistance in a CFD analysis to achieve uniform air conditioning to the furthest corners of the room.

Mitsubishi Heavy Industries

FDK-KXZE1

Wall mounted indoor unit -Stylishly designed with rounded contours that fit beautifully into any of Europe’s diverse interior settings -Flap control system -The air flow design that's proven to minimise resistance in a CFD analysis to achieve uniform air conditioning to the furthest corners of the room.

EMCS compliant

.DWG .RFA .IFC

Unidad de aire acondicionado

Mitsubishi Heavy Industries

Descargar
Mitsubishi Heavy Industries FDT-KXZE1

FDT-KXZE1

Ceiling Cassette -4way-indoor unit -Draft Prevention Panel as an option -Individual flap control system -Drain can be discharged upwards by 850mm from the ceiling surface. -Motion Sensor to improve the comfort and energy saving performance of the unit. -Component design can acheive better aerodynamic perfromance and lower noise level.

Mitsubishi Heavy Industries

FDT-KXZE1

Ceiling Cassette -4way-indoor unit -Draft Prevention Panel as an option -Individual flap control system -Drain can be discharged upwards by 850mm from the ceiling surface. -Motion Sensor to improve the comfort and energy saving performance of the unit. -Component design can acheive better aerodynamic perfromance and lower noise level.

EMCS compliant

.DWG .RFA .IFC

Unidad de aire acondicionado

Mitsubishi Heavy Industries

Descargar
Mitsubishi Heavy Industries FDTC-KXZE1

FDTC-KXZE1

Ceiling Cassette -4way Compact Indoor Unit -European design & Flat panel -Draft Prevention Panel as an option -Individual flap control system -Motion Sensor to improve the comfort and energy saving performance of the unit.

Mitsubishi Heavy Industries

FDTC-KXZE1

Ceiling Cassette -4way Compact Indoor Unit -European design & Flat panel -Draft Prevention Panel as an option -Individual flap control system -Motion Sensor to improve the comfort and energy saving performance of the unit.

EMCS compliant

.DWG .RFA .IFC

Unidad de aire acondicionado

Mitsubishi Heavy Industries

Descargar
Mitsubishi Heavy Industries FDC-KXZRE1

FDC-KXZRE1

KXZR Heat Recovery VRF outdoor unit -Simultaneous heating and cooling operations of individual indoor units. -Energy efficiency is maximised by employing Multi-port DC Inverter compressor with concentrated electric winding -Total piping length up to 1000m and a maximum pipe run of 160m. - Wide range of controls, central controls and BMS systems are available.

Mitsubishi Heavy Industries

FDC-KXZRE1

KXZR Heat Recovery VRF outdoor unit -Simultaneous heating and cooling operations of individual indoor units. -Energy efficiency is maximised by employing Multi-port DC Inverter compressor with concentrated electric winding -Total piping length up to 1000m and a maximum pipe run of 160m. - Wide range of controls, central controls and BMS systems are available.

EMCS compliant

.DWG .RFA .IFC

Bomba de calor

Mitsubishi Heavy Industries

Descargar
Mitsubishi Heavy Industries FDC-KXZRXE1

FDC-KXZRXE1

KXZRX Hi-COP Heat Recovery VRF outdoor unit -Simultaneous heating and cooling operations of individual indoor units. Maximum energy efficiency: COP 4.76 -Energy efficiency is maximised by employing Multi-port DC Inverter compressor with concentrated electric winding -Total piping length up to 1000m and a maximum pipe run of 160m. - Wide range of controls, central controls and BMS systems are available.

Mitsubishi Heavy Industries

FDC-KXZRXE1

KXZRX Hi-COP Heat Recovery VRF outdoor unit -Simultaneous heating and cooling operations of individual indoor units. Maximum energy efficiency: COP 4.76 -Energy efficiency is maximised by employing Multi-port DC Inverter compressor with concentrated electric winding -Total piping length up to 1000m and a maximum pipe run of 160m. - Wide range of controls, central controls and BMS systems are available.

EMCS compliant

.DWG .RFA .IFC

Bomba de calor

Mitsubishi Heavy Industries

Descargar
Valsir PP3 PP Firenze trap with access

PP3 PP Firenze trap with access

Firenze trap with access

Valsir

PP3 PP Firenze trap with access

Firenze trap with access

EMCS compliant

.RFA

Componentes para instalaciones de saneamiento y de alcantarillado

Valsir

Descargar
Valsir PP3 PP Double increaser

PP3 PP Double increaser

Double increaser

Valsir

PP3 PP Double increaser

Double increaser

EMCS compliant

.RFA

Componentes para instalaciones de saneamiento y de alcantarillado

Valsir

Descargar
Valsir PP3 PP 87°30’ corner branch

PP3 PP 87°30’ corner branch

87°30’ corner branch

Valsir

PP3 PP 87°30’ corner branch

87°30’ corner branch

EMCS compliant

.RFA

Componentes para instalaciones de saneamiento y de alcantarillado

Valsir

Descargar
Valsir PP3 PP Straight fitting with cap

PP3 PP Straight fitting with cap

Straight fitting with cap

Valsir

PP3 PP Straight fitting with cap

Straight fitting with cap

EMCS compliant

.RFA

Componentes para instalaciones de saneamiento y de alcantarillado

Valsir

Descargar
Valsir Silere Parallel branch

Silere Parallel branch

Parallel branch

Valsir

Silere Parallel branch

Parallel branch

EMCS compliant

.RFA

Componentes para instalaciones de saneamiento y de alcantarillado

Valsir

Descargar
Valsir PP3 PP Bend for trap connection with cap, without grommet

PP3 PP Bend for trap connection with cap, without grommet

Bend for trap connection with cap, without grommet

Valsir

PP3 PP Bend for trap connection with cap, without grommet

Bend for trap connection with cap, without grommet

EMCS compliant

.RFA

Componentes para instalaciones de saneamiento y de alcantarillado

Valsir

Descargar
Valsir PP3 PP Bend for trap connection with cap, without grommet

PP3 PP Bend for trap connection with cap, without grommet

Bend for trap connection with cap, without grommet

Valsir

PP3 PP Bend for trap connection with cap, without grommet

Bend for trap connection with cap, without grommet

EMCS compliant

.RFA

Componentes para instalaciones de saneamiento y de alcantarillado

Valsir

Descargar
Valsir PP3 PP Grey bend with right inlet

PP3 PP Grey bend with right inlet

Grey bend with right inlet

Valsir

PP3 PP Grey bend with right inlet

Grey bend with right inlet

EMCS compliant

.RFA

Componentes para instalaciones de saneamiento y de alcantarillado

Valsir

Descargar
Valsir PP3 PP Grey bend with two inlets

PP3 PP Grey bend with two inlets

Grey bend with two inlets

Valsir

PP3 PP Grey bend with two inlets

Grey bend with two inlets

EMCS compliant

.RFA

Componentes para instalaciones de saneamiento y de alcantarillado

Valsir

Descargar
Valsir PP3 PP Grey bend with left inlet

PP3 PP Grey bend with left inlet

Grey bend with left inlet

Valsir

PP3 PP Grey bend with left inlet

Grey bend with left inlet

EMCS compliant

.RFA

Componentes para instalaciones de saneamiento y de alcantarillado

Valsir

Descargar
Valsir PP3 PP 87°30’ bend with front inlet with seal

PP3 PP 87°30’ bend with front inlet with seal

87°30’ bend with front inlet with seal

Valsir

PP3 PP 87°30’ bend with front inlet with seal

87°30’ bend with front inlet with seal

EMCS compliant

.RFA

Componentes para instalaciones de saneamiento y de alcantarillado

Valsir

Descargar
Valsir PP3 PP Back to back connector for trap with caps

PP3 PP Back to back connector for trap with caps

Back to back connector for trap with caps

Valsir

PP3 PP Back to back connector for trap with caps

Back to back connector for trap with caps

EMCS compliant

.RFA

Componentes para instalaciones de saneamiento y de alcantarillado

Valsir

Descargar
Rendamax R3601-R3610 EVO

R3601-R3610 EVO

System Boiler

Rendamax

R3601-R3610 EVO

System Boiler

EMCS compliant

.DWG .RFA .IFC

Boiler

Rendamax

Descargar
Rendamax R3501-R3509 EVO

R3501-R3509 EVO

System Boiler

Rendamax

R3501-R3509 EVO

System Boiler

EMCS compliant

.DWG .RFA .IFC

Boiler

Rendamax

Descargar
Rendamax R3401-R3410 EVO

R3401-R3410 EVO

System Boiler

Rendamax

R3401-R3410 EVO

System Boiler

EMCS compliant

.DWG .RFA .IFC

Boiler

Rendamax

Descargar
Rendamax R604-R607 EVO IP

R604-R607 EVO IP

Central, Industrial and Water Heating IP

Rendamax

R604-R607 EVO IP

Central, Industrial and Water Heating IP

EMCS compliant

.DWG .RFA .IFC

Boiler

Rendamax

Descargar
Rendamax R604-R607 EVO

R604-R607 EVO

Central, Industrial and Water Heating

Rendamax

R604-R607 EVO

Central, Industrial and Water Heating

EMCS compliant

.DWG .RFA .IFC

Boiler

Rendamax

Descargar
Rendamax R604-R607 EVO IND

R604-R607 EVO IND

Central, Industrial and Water Heating IND

Rendamax

R604-R607 EVO IND

Central, Industrial and Water Heating IND

EMCS compliant

.DWG .RFA .IFC

Boiler

Rendamax

Descargar
Rendamax R601-R603 EVO IP

R601-R603 EVO IP

Central, Industrial and Water Heating IP

Rendamax

R601-R603 EVO IP

Central, Industrial and Water Heating IP

EMCS compliant

.DWG .RFA .IFC

Boiler

Rendamax

Descargar
Rendamax R601-R603 EVO

R601-R603 EVO

Central, Industrial and Water Heating

Rendamax

R601-R603 EVO

Central, Industrial and Water Heating

EMCS compliant

.DWG .RFA .IFC

Boiler

Rendamax

Descargar
Rendamax R601-R603 EVO IND

R601-R603 EVO IND

Central, Industrial and Water Heating IND

Rendamax

R601-R603 EVO IND

Central, Industrial and Water Heating IND

EMCS compliant

.DWG .RFA .IFC

Boiler

Rendamax

Descargar
Rendamax R40 EVO 60-140 IP

R40 EVO 60-140 IP

Central, Industrial and Water Heating IP

Rendamax

R40 EVO 60-140 IP

Central, Industrial and Water Heating IP

EMCS compliant

.DWG .RFA .IFC

Boiler

Rendamax

Descargar
Rendamax R40 EVO 60-140

R40 EVO 60-140

Central, Industrial and Water Heating

Rendamax

R40 EVO 60-140

Central, Industrial and Water Heating

EMCS compliant

.DWG .RFA .IFC

Boiler

Rendamax

Descargar
Rendamax R40 EVO 6Boiler BackToBack DN100

R40 EVO 6Boiler BackToBack DN100

Central, Industrial and Water Heating

Rendamax

R40 EVO 6Boiler BackToBack DN100

Central, Industrial and Water Heating

EMCS compliant

.DWG .RFA .IFC

Boiler

Rendamax

Descargar
Rendamax R40 EVO 6Boiler BackToBack DN065

R40 EVO 6Boiler BackToBack DN065

Central, Industrial and Water Heating

Rendamax

R40 EVO 6Boiler BackToBack DN065

Central, Industrial and Water Heating

EMCS compliant

.DWG .RFA .IFC

Boiler

Rendamax

Descargar
Rendamax R40 EVO 4Boiler BackToBack DN100

R40 EVO 4Boiler BackToBack DN100

Central, Industrial and Water Heating

Rendamax

R40 EVO 4Boiler BackToBack DN100

Central, Industrial and Water Heating

EMCS compliant

.DWG .RFA .IFC

Boiler

Rendamax

Descargar
Rendamax R40 EVO 4Boiler BackToBack DN065

R40 EVO 4Boiler BackToBack DN065

Central, Industrial and Water Heating

Rendamax

R40 EVO 4Boiler BackToBack DN065

Central, Industrial and Water Heating

EMCS compliant

.DWG .RFA .IFC

Boiler

Rendamax

Descargar
Rendamax R40 EVO 3Boiler Inline DN100

R40 EVO 3Boiler Inline DN100

Central, Industrial and Water Heating

Rendamax

R40 EVO 3Boiler Inline DN100

Central, Industrial and Water Heating

EMCS compliant

.DWG .RFA .IFC

Boiler

Rendamax

Descargar
Rendamax R40 EVO 3Boiler Inline DN065

R40 EVO 3Boiler Inline DN065

Central, Industrial and Water Heating

Rendamax

R40 EVO 3Boiler Inline DN065

Central, Industrial and Water Heating

EMCS compliant

.DWG .RFA .IFC

Boiler

Rendamax

Descargar
Rendamax R40 EVO 2Boiler Wall DN100

R40 EVO 2Boiler Wall DN100

Central, Industrial and Water Heating

Rendamax

R40 EVO 2Boiler Wall DN100

Central, Industrial and Water Heating

EMCS compliant

.DWG .RFA .IFC

Boiler

Rendamax

Descargar
Rendamax R40 EVO 2Boiler Inline ND065

R40 EVO 2Boiler Inline ND065

Central, Industrial and Water Heating

Rendamax

R40 EVO 2Boiler Inline ND065

Central, Industrial and Water Heating

EMCS compliant

.DWG .RFA .IFC

Boiler

Rendamax

Descargar
Rendamax R40 EVO 2Boiler Inline DN100

R40 EVO 2Boiler Inline DN100

Central, Industrial and Water Heating

Rendamax

R40 EVO 2Boiler Inline DN100

Central, Industrial and Water Heating

EMCS compliant

.DWG .RFA .IFC

Boiler

Rendamax

Descargar
Rendamax R40 ECO 70-120

R40 ECO 70-120

Central and Water Heating

Rendamax

R40 ECO 70-120

Central and Water Heating

EMCS compliant

.DWG .RFA .IFC

Boiler

Rendamax

Descargar
Rendamax R40 ECO 6Boiler BackToBack DN100

R40 ECO 6Boiler BackToBack DN100

Central and Water Heating

Rendamax

R40 ECO 6Boiler BackToBack DN100

Central and Water Heating

EMCS compliant

.DWG .RFA .IFC

Boiler

Rendamax

Descargar
Rendamax R40 ECO 6Boiler BackToBack DN065

R40 ECO 6Boiler BackToBack DN065

Central and Water Heating

Rendamax

R40 ECO 6Boiler BackToBack DN065

Central and Water Heating

EMCS compliant

.DWG .RFA .IFC

Boiler

Rendamax

Descargar
Rendamax R40 ECO 4Boiler BackToBack DN100

R40 ECO 4Boiler BackToBack DN100

Central and Water Heating

Rendamax

R40 ECO 4Boiler BackToBack DN100

Central and Water Heating

EMCS compliant

.DWG .RFA .IFC

Boiler

Rendamax

Descargar
Rendamax R40 ECO 4Boiler BackToBack DN065

R40 ECO 4Boiler BackToBack DN065

Central and Water Heating

Rendamax

R40 ECO 4Boiler BackToBack DN065

Central and Water Heating

EMCS compliant

.DWG .RFA .IFC

Boiler

Rendamax

Descargar
Rendamax R40 ECO 3Boiler Wall DN100

R40 ECO 3Boiler Wall DN100

Central and Water Heating

Rendamax

R40 ECO 3Boiler Wall DN100

Central and Water Heating

EMCS compliant

.DWG .RFA .IFC

Boiler

Rendamax

Descargar
Rendamax R40 ECO 3Boiler Wall DN065

R40 ECO 3Boiler Wall DN065

Central and Water Heating

Rendamax

R40 ECO 3Boiler Wall DN065

Central and Water Heating

EMCS compliant

.DWG .RFA .IFC

Boiler

Rendamax

Descargar
Rendamax R40 ECO 3Boiler InlineFree DN100

R40 ECO 3Boiler InlineFree DN100

Central and Water Heating

Rendamax

R40 ECO 3Boiler InlineFree DN100

Central and Water Heating

EMCS compliant

.DWG .RFA .IFC

Boiler

Rendamax

Descargar
Rendamax R40 ECO 3Boiler InlineFree DN065

R40 ECO 3Boiler InlineFree DN065

Central and Water Heating

Rendamax

R40 ECO 3Boiler InlineFree DN065

Central and Water Heating

EMCS compliant

.DWG .RFA .IFC

Boiler

Rendamax

Descargar
Rendamax R40 ECO 2Boiler Wall DN100

R40 ECO 2Boiler Wall DN100

Central and Water Heating

Rendamax

R40 ECO 2Boiler Wall DN100

Central and Water Heating

EMCS compliant

.DWG .RFA .IFC

Boiler

Rendamax

Descargar
Rendamax R40 ECO 2Boiler Wall DN065

R40 ECO 2Boiler Wall DN065

Central and Water Heating

Rendamax

R40 ECO 2Boiler Wall DN065

Central and Water Heating

EMCS compliant

.DWG .RFA .IFC

Boiler

Rendamax

Descargar
Rendamax R40 ECO 2Boiler InlineFre DN100

R40 ECO 2Boiler InlineFre DN100

Central and Water Heating

Rendamax

R40 ECO 2Boiler InlineFre DN100

Central and Water Heating

EMCS compliant

.DWG .RFA .IFC

Boiler

Rendamax

Descargar
Rendamax R40 ECO 2Boiler InlineFree DN065

R40 ECO 2Boiler InlineFree DN065

Central and Water Heating

Rendamax

R40 ECO 2Boiler InlineFree DN065

Central and Water Heating

EMCS compliant

.DWG .RFA .IFC

Boiler

Rendamax

Descargar
Unspecified Urinal Control

Urinal Control

Unspecified Urinal Control

Unspecified

Urinal Control

Unspecified Urinal Control

EMCS compliant

.DWG .RFA .IFC

Panel de control

Unspecified

Descargar
Mitsubishi Electric Mitsubishi Electric System Designer

Mitsubishi Electric System Designer

Find quickly Mitsubishi Electric content and place it directly in Revit or Autocad with this free App. The Mitsubishi Electric System Designer App for Revit and AutoCAD is a powerful tool allowing you to find the right Mitsubishi Electric Revit families and CAD files for heating and cooling units that you need. Filter the Mitsubishi Electric HVAC units on technical properties or search on article number, description, model or series and use your desired air conditioners in your BIM projects instantly. The following product series are available in the app: City Multi, Ecodan, E-series, Lossnay, M Series, Mr. Slim. Download the free app now! You can download the app for free from [a href="https://store.mepcontent.com/Product/Details/49" target="_blank"]our store[/a].

Mitsubishi Electric

Mitsubishi Electric System Designer

Find quickly Mitsubishi Electric content and place it directly in Revit or Autocad with this free App. The Mitsubishi Electric System Designer App for Revit and AutoCAD is a powerful tool allowing you to find the right Mitsubishi Electric Revit families and CAD files for heating and cooling units that you need. Filter the Mitsubishi Electric HVAC units on technical properties or search on article number, description, model or series and use your desired air conditioners in your BIM projects instantly. The following product series are available in the app: City Multi, Ecodan, E-series, Lossnay, M Series, Mr. Slim. Download the free app now! You can download the app for free from [a href="https://store.mepcontent.com/Product/Details/49" target="_blank"]our store[/a].

EMCS compliant

.PDF

Unidad de aire acondicionado

Mitsubishi Electric

Descargar
Wavin Wavin Hep2O Piping system

Wavin Hep2O Piping system

Piping system from Wavin Hep2O

Wavin

Wavin Hep2O Piping system

Piping system from Wavin Hep2O

.PLS for Stabicad

Calefacción y aire acondicionado

Wavin

View
ELCO CHP VARION C Power S

CHP VARION C Power S

Combined Heat and Power Units

ELCO

CHP VARION C Power S

Combined Heat and Power Units

EMCS compliant

.DWG .RFA .IFC

Distribuidor para calefacción y aire acondicionado

ELCO

Descargar
ELCO CHP VARION C Power M

CHP VARION C Power M

Combined Heat and Power Units

ELCO

CHP VARION C Power M

Combined Heat and Power Units

EMCS compliant

.DWG .RFA .IFC

Distribuidor para calefacción y aire acondicionado

ELCO

Descargar
ELCO CHP VARION C Power M Plus

CHP VARION C Power M Plus

Combined Heat and Power Units

ELCO

CHP VARION C Power M Plus

Combined Heat and Power Units

EMCS compliant

.DWG .RFA .IFC

Distribuidor para calefacción y aire acondicionado

ELCO

Descargar
ELCO CHP VARION C Power L

CHP VARION C Power L

Combined Heat and Power Units

ELCO

CHP VARION C Power L

Combined Heat and Power Units

EMCS compliant

.DWG .RFA .IFC

Distribuidor para calefacción y aire acondicionado

ELCO

Descargar
ELCO ThisionLEVOCascade, DN100 Header

ThisionLEVOCascade, DN100 Header

DN100 Header

EMCS compliant

.DWG .RFA .IFC

Boiler

ELCO

Descargar
ELCO ThisionLEVOCascade, DN65 Header

ThisionLEVOCascade, DN65 Header

DN65 Header

EMCS compliant

.DWG .RFA .IFC

Boiler

ELCO

Descargar
ELCO ThisionLEVOCascade, 6 Boiler Cascade, Back to Back, DN100

ThisionLEVOCascade, 6 Boiler Cascade, Back to Back, DN100

6 Boiler Cascade, Back to Back, DN100

ELCO

ThisionLEVOCascade, 6 Boiler Cascade, Back to Back, DN100

6 Boiler Cascade, Back to Back, DN100

EMCS compliant

.DWG .RFA .IFC

Boiler

ELCO

Descargar
ELCO ThisionLEVOCascade, 6 Boiler Cascade, Back to Back, DN65

ThisionLEVOCascade, 6 Boiler Cascade, Back to Back, DN65

6 Boiler Cascade, Back to Back, DN65

ELCO

ThisionLEVOCascade, 6 Boiler Cascade, Back to Back, DN65

6 Boiler Cascade, Back to Back, DN65

EMCS compliant

.DWG .RFA .IFC

Boiler

ELCO

Descargar
ELCO TThisionLEVOCascade, 4 Boiler Cascade, Back to Back, DN100

TThisionLEVOCascade, 4 Boiler Cascade, Back to Back, DN100

4 Boiler Cascade, Back to Back, DN100

ELCO

TThisionLEVOCascade, 4 Boiler Cascade, Back to Back, DN100

4 Boiler Cascade, Back to Back, DN100

EMCS compliant

.DWG .RFA .IFC

Boiler

ELCO

Descargar
ELCO ThisionLEVOCascade, 4 Boiler Cascade, Back to Back, DN65

ThisionLEVOCascade, 4 Boiler Cascade, Back to Back, DN65

4 Boiler Cascade, Back to Back, DN65

ELCO

ThisionLEVOCascade, 4 Boiler Cascade, Back to Back, DN65

4 Boiler Cascade, Back to Back, DN65

EMCS compliant

.DWG .RFA .IFC

Boiler

ELCO

Descargar
ELCO ThisionLEVOCascade, 3 Boiler Cascade, Inline, DN100

ThisionLEVOCascade, 3 Boiler Cascade, Inline, DN100

3 Boiler Cascade, Inline, DN100

ELCO

ThisionLEVOCascade, 3 Boiler Cascade, Inline, DN100

3 Boiler Cascade, Inline, DN100

EMCS compliant

.DWG .RFA .IFC

Boiler

ELCO

Descargar
ELCO ThisionLEVOCascade, 3 Boiler Cascade, Inline, DN65

ThisionLEVOCascade, 3 Boiler Cascade, Inline, DN65

3 Boiler Cascade, Inline, DN65

ELCO

ThisionLEVOCascade, 3 Boiler Cascade, Inline, DN65

3 Boiler Cascade, Inline, DN65

EMCS compliant

.DWG .RFA .IFC

Boiler

ELCO

Descargar
ELCO ThisionLEVOCascade, 2 Boiler Cascade, Wall, DN100

ThisionLEVOCascade, 2 Boiler Cascade, Wall, DN100

2 Boiler Cascade, Wall, DN100

ELCO

ThisionLEVOCascade, 2 Boiler Cascade, Wall, DN100

2 Boiler Cascade, Wall, DN100

EMCS compliant

.DWG .RFA .IFC

Boiler

ELCO

Descargar
ELCO ThisionLEVOCascade, 2 Boiler Cascade, Inline, DN100

ThisionLEVOCascade, 2 Boiler Cascade, Inline, DN100

2 Boiler Cascade, Inline, DN100

ELCO

ThisionLEVOCascade, 2 Boiler Cascade, Inline, DN100

2 Boiler Cascade, Inline, DN100

EMCS compliant

.DWG .RFA .IFC

Boiler

ELCO

Descargar
ELCO ThisionLEVOCascade, 2 Boiler Cascade, Inline, DN65

ThisionLEVOCascade, 2 Boiler Cascade, Inline, DN65

2 Boiler Cascade, Inline, DN65

ELCO

ThisionLEVOCascade, 2 Boiler Cascade, Inline, DN65

2 Boiler Cascade, Inline, DN65

EMCS compliant

.DWG .RFA .IFC

Boiler

ELCO

Descargar
ELCO ThisionCascade, 6 Boiler Cascade, Back to Back, DN100

ThisionCascade, 6 Boiler Cascade, Back to Back, DN100

6 Boiler Cascade, Back to Back, DN100

ELCO

ThisionCascade, 6 Boiler Cascade, Back to Back, DN100

6 Boiler Cascade, Back to Back, DN100

EMCS compliant

.DWG .RFA .IFC

Boiler

ELCO

Descargar
ELCO ThisionCascade, 6 Boiler Cascade, Back to Back, DN65

ThisionCascade, 6 Boiler Cascade, Back to Back, DN65

6 Boiler Cascade, Back to Back, DN65

ELCO

ThisionCascade, 6 Boiler Cascade, Back to Back, DN65

6 Boiler Cascade, Back to Back, DN65

EMCS compliant

.DWG .RFA .IFC

Boiler

ELCO

Descargar
ELCO ThisionCascade, 4 Boiler Cascade, Back to Back, DN100

ThisionCascade, 4 Boiler Cascade, Back to Back, DN100

4 Boiler Cascade, Back to Back, DN100

ELCO

ThisionCascade, 4 Boiler Cascade, Back to Back, DN100

4 Boiler Cascade, Back to Back, DN100

EMCS compliant

.DWG .RFA .IFC

Boiler

ELCO

Descargar
ELCO ThisionCascade,  4 Boiler Cascade, Back to Back, DN65

ThisionCascade, 4 Boiler Cascade, Back to Back, DN65

4 Boiler Cascade, Back to Back, DN65

ELCO

ThisionCascade, 4 Boiler Cascade, Back to Back, DN65

4 Boiler Cascade, Back to Back, DN65

EMCS compliant

.DWG .RFA .IFC

Boiler

ELCO

Descargar
ELCO ThisionCascade, 3 Boiler Cascade, Wall Mounted, DN100

ThisionCascade, 3 Boiler Cascade, Wall Mounted, DN100

3 Boiler Cascade, Wall Mounted, DN100

ELCO

ThisionCascade, 3 Boiler Cascade, Wall Mounted, DN100

3 Boiler Cascade, Wall Mounted, DN100

EMCS compliant

.DWG .RFA .IFC

Boiler

ELCO

Descargar
ELCO ThisionCascade, 3 Boiler Cascade, Wall Mounted, DN65

ThisionCascade, 3 Boiler Cascade, Wall Mounted, DN65

3 Boiler Cascade, Wall Mounted, DN65

ELCO

ThisionCascade, 3 Boiler Cascade, Wall Mounted, DN65

3 Boiler Cascade, Wall Mounted, DN65

EMCS compliant

.DWG .RFA .IFC

Boiler

ELCO

Descargar
ELCO ThisionCascade, 3 Boiler Cascade,  Inline Free Standing, DN100

ThisionCascade, 3 Boiler Cascade, Inline Free Standing, DN100

3 Boiler Cascade, Inline Free Standing, DN100

ELCO

ThisionCascade, 3 Boiler Cascade, Inline Free Standing, DN100

3 Boiler Cascade, Inline Free Standing, DN100

EMCS compliant

.DWG .RFA .IFC

Boiler

ELCO

Descargar
ELCO ThisionCascade, 3 Boiler Cascade, Inline Free Standing, DN65

ThisionCascade, 3 Boiler Cascade, Inline Free Standing, DN65

3 Boiler Cascade, Inline Free Standing, DN65

ELCO

ThisionCascade, 3 Boiler Cascade, Inline Free Standing, DN65

3 Boiler Cascade, Inline Free Standing, DN65

EMCS compliant

.DWG .RFA .IFC

Boiler

ELCO

Descargar
ELCO ThisionCascade, 2 Boiler Cascade, Wall Mounted, DN100

ThisionCascade, 2 Boiler Cascade, Wall Mounted, DN100

2 Boiler Cascade, Wall Mounted, DN100

ELCO

ThisionCascade, 2 Boiler Cascade, Wall Mounted, DN100

2 Boiler Cascade, Wall Mounted, DN100

EMCS compliant

.DWG .RFA .IFC

Boiler

ELCO

Descargar
ELCO ThisionCascade, 2 Boiler Cascade, Wall Mounted, DN65

ThisionCascade, 2 Boiler Cascade, Wall Mounted, DN65

2 Boiler Cascade, Wall Mounted, DN65

ELCO

ThisionCascade, 2 Boiler Cascade, Wall Mounted, DN65

2 Boiler Cascade, Wall Mounted, DN65

EMCS compliant

.DWG .RFA .IFC

Boiler

ELCO

Descargar
ELCO ThisionCascade, 2 Boiler Cascade, Inline Free Standing, DN100

ThisionCascade, 2 Boiler Cascade, Inline Free Standing, DN100

2 Boiler Cascade, Inline Free Standing, DN100

ELCO

ThisionCascade, 2 Boiler Cascade, Inline Free Standing, DN100

2 Boiler Cascade, Inline Free Standing, DN100

EMCS compliant

.DWG .RFA .IFC

Boiler

ELCO

Descargar
ELCO ThisionCascade, 2 Boiler Cascade, Inline Free Standing, DN65

ThisionCascade, 2 Boiler Cascade, Inline Free Standing, DN65

2 Boiler Cascade, Inline Free Standing, DN65

ELCO

ThisionCascade, 2 Boiler Cascade, Inline Free Standing, DN65

2 Boiler Cascade, Inline Free Standing, DN65

EMCS compliant

.DWG .RFA .IFC

Boiler

ELCO

Descargar
Remeha Tzerra HP

Tzerra HP

Boiler

Remeha

Tzerra HP

Boiler

EMCS compliant

.DWG .RFA .IFC

Boiler

Remeha

Descargar
IVAR PICV 00-05-10 With PICC 01-02-03

PICV 00-05-10 With PICC 01-02-03

Valve that keeps the flow rate constant during operation within a certain differential pressure range thanks to a membrane device with a contrast spring. Complete with two pockets G 1/4"F for piezometric sockets (IVAR AVB 10) and with plugs for piezometric sockets and cartridge. PICV 00 (female) connections: G 1/2"F, G 3/4"F, G 1"F in compliance with ISO 228/1. PICV 05 (male - flat seal) connections: G 3/4"M, EUROK, G 1"M, G 1"1/4M in compliance with ISO 228/1. PICV 10 (with unions) connections: G 1/2"M, G 3/4"M, G 1"M in compliance with ISO 228/1 and EN 10226-1. To combine with PICC 01, PICC 02 or PICC 03 cartridges. PICC connection: M32x1.5. Compatible with water or glycol solutions max 30%. Min operating temperature: -20 °C. Max operating temperature: 120 °C. Max operating pressure: 25 bar. Max closing pressure with PICC 03: 6 bar. Valve material: CW617N brass. Sealing gaskets material: Peroxide EPDM. IVAR PICC 01: 8 flow rate ranges to set; brass and POM insert; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets. IVAR PICC 02: 41 flow rate ranges to set even during operation; brass and PSU insert; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets. IVAR PICC 03: 41 flow rate ranges to set even during operation; to combine with IVAR TE 3003 electrothermal actuator (M30x1.5; ON/OFF 230 V AC or ON/OFF 24 V AC or proportional 0-10 V 24 V AC adjustment) or IVAR RV 03 axial motor (M30x1.5; 2 points/3 points 230 V AC or 2 points/3 points 24 V AC or proportional 0-10 V 24 V AC adjustment); max closing pressure 6 bar; brass and PSU/POM/PPS (glass-fibre reinforced) insert; stainless steel internal metal components; PPS/Peroxide EPDM cone; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets.

IVAR

PICV 00-05-10 With PICC 01-02-03

Valve that keeps the flow rate constant during operation within a certain differential pressure range thanks to a membrane device with a contrast spring. Complete with two pockets G 1/4"F for piezometric sockets (IVAR AVB 10) and with plugs for piezometric sockets and cartridge. PICV 00 (female) connections: G 1/2"F, G 3/4"F, G 1"F in compliance with ISO 228/1. PICV 05 (male - flat seal) connections: G 3/4"M, EUROK, G 1"M, G 1"1/4M in compliance with ISO 228/1. PICV 10 (with unions) connections: G 1/2"M, G 3/4"M, G 1"M in compliance with ISO 228/1 and EN 10226-1. To combine with PICC 01, PICC 02 or PICC 03 cartridges. PICC connection: M32x1.5. Compatible with water or glycol solutions max 30%. Min operating temperature: -20 °C. Max operating temperature: 120 °C. Max operating pressure: 25 bar. Max closing pressure with PICC 03: 6 bar. Valve material: CW617N brass. Sealing gaskets material: Peroxide EPDM. IVAR PICC 01: 8 flow rate ranges to set; brass and POM insert; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets. IVAR PICC 02: 41 flow rate ranges to set even during operation; brass and PSU insert; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets. IVAR PICC 03: 41 flow rate ranges to set even during operation; to combine with IVAR TE 3003 electrothermal actuator (M30x1.5; ON/OFF 230 V AC or ON/OFF 24 V AC or proportional 0-10 V 24 V AC adjustment) or IVAR RV 03 axial motor (M30x1.5; 2 points/3 points 230 V AC or 2 points/3 points 24 V AC or proportional 0-10 V 24 V AC adjustment); max closing pressure 6 bar; brass and PSU/POM/PPS (glass-fibre reinforced) insert; stainless steel internal metal components; PPS/Peroxide EPDM cone; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets.

EMCS compliant

.RFA

Válvula para calefacción y refrigeración

IVAR

Descargar
IVAR LEGIO-BOX 3

LEGIO-BOX 3

Temperature control and thermal disinfection multifunctional unit for sanitary systems. It allows the temporary by-pass of the thermostatic mixing valve to supply high-temperature water to the system terminal units for the thermal disinfection. Provided with/without thermoelectric actuator on the three-way valve. Shut-off ball valves at the inlets. Thermoelectric actuator: ON/OFF 230 V AC normally closed (2 wires). Max fluid temperature: 90° C. Maximum operating pressure: 10 bar. Max pressure differential at three-way valve ends: 1 bar. Main body material: CW617N brass. Branches material: copper. Sealing elements material: Peroxide EPDM. Inlet connections: 3/4” F. Outlet connections: 3/4" M. Dimensions (W x H x D): 295 x 290 x 75 mm.

IVAR

LEGIO-BOX 3

Temperature control and thermal disinfection multifunctional unit for sanitary systems. It allows the temporary by-pass of the thermostatic mixing valve to supply high-temperature water to the system terminal units for the thermal disinfection. Provided with/without thermoelectric actuator on the three-way valve. Shut-off ball valves at the inlets. Thermoelectric actuator: ON/OFF 230 V AC normally closed (2 wires). Max fluid temperature: 90° C. Maximum operating pressure: 10 bar. Max pressure differential at three-way valve ends: 1 bar. Main body material: CW617N brass. Branches material: copper. Sealing elements material: Peroxide EPDM. Inlet connections: 3/4” F. Outlet connections: 3/4" M. Dimensions (W x H x D): 295 x 290 x 75 mm.

EMCS compliant

.RFA

Panel de control

IVAR

Descargar
IVAR LEGIO-BOX 2

LEGIO-BOX 2

Temperature control and thermal disinfection multifunctional unit for sanitary systems. It allows the temporary by-pass of the thermostatic mixing valve to supply high-temperature water to the system terminal units for the thermal disinfection. Provided with/without thermoelectric actuator on the three-way valve, with box and fastening kit. Shut-off ball valves at the inlets. Thermoelectric actuator: ON/OFF 230 V AC normally closed (2 wires). Max fluid temperature: 90° C. Maximum operating pressure: 10 bar. Max pressure differential at three-way valve ends: 1 bar. Main body material: CW617N brass. Box material: high impact polystyrene. Branches material: copper. Sealing elements material: Peroxide EPDM. Inlet connections: 3/4” F. Outlet connections: 3/4" M. Box dimensions (W x H x D): 500 x 350 x 90 mm.

IVAR

LEGIO-BOX 2

Temperature control and thermal disinfection multifunctional unit for sanitary systems. It allows the temporary by-pass of the thermostatic mixing valve to supply high-temperature water to the system terminal units for the thermal disinfection. Provided with/without thermoelectric actuator on the three-way valve, with box and fastening kit. Shut-off ball valves at the inlets. Thermoelectric actuator: ON/OFF 230 V AC normally closed (2 wires). Max fluid temperature: 90° C. Maximum operating pressure: 10 bar. Max pressure differential at three-way valve ends: 1 bar. Main body material: CW617N brass. Box material: high impact polystyrene. Branches material: copper. Sealing elements material: Peroxide EPDM. Inlet connections: 3/4” F. Outlet connections: 3/4" M. Box dimensions (W x H x D): 500 x 350 x 90 mm.

EMCS compliant

.RFA

Panel de control

IVAR

Descargar
IVAR LEGIO-BOX 1

LEGIO-BOX 1

Temperature control and thermal disinfection multifunctional unit for sanitary systems. It allows the temporary by-pass of the thermostatic mixing valve to supply high-temperature water to the system terminal units for the thermal disinfection. Provided with/without thermoelectric actuator on the three-way valve, with manifolds, box and fastening kit. Shut-off ball valves at the inlets. Thermoelectric actuator: ON/OFF 230 V AC normally closed (2 wires). Max fluid temperature: 90° C. Maximum operating pressure: 10 bar. Max pressure differential at three-way valve ends: 1 bar. Main body material: CW617N brass (externally zinc-plated). Manifolds material: CW617N brass (externally zinc-plated). Box material: high impact polystyrene. Branches material: copper. Sealing elements material: Peroxide EPDM. Inlet connections: 3/4” F. Outlet connections: EUROK. Box dimensions (W x H x D): 500 x 350 x 90 mm.

IVAR

LEGIO-BOX 1

Temperature control and thermal disinfection multifunctional unit for sanitary systems. It allows the temporary by-pass of the thermostatic mixing valve to supply high-temperature water to the system terminal units for the thermal disinfection. Provided with/without thermoelectric actuator on the three-way valve, with manifolds, box and fastening kit. Shut-off ball valves at the inlets. Thermoelectric actuator: ON/OFF 230 V AC normally closed (2 wires). Max fluid temperature: 90° C. Maximum operating pressure: 10 bar. Max pressure differential at three-way valve ends: 1 bar. Main body material: CW617N brass (externally zinc-plated). Manifolds material: CW617N brass (externally zinc-plated). Box material: high impact polystyrene. Branches material: copper. Sealing elements material: Peroxide EPDM. Inlet connections: 3/4” F. Outlet connections: EUROK. Box dimensions (W x H x D): 500 x 350 x 90 mm.

EMCS compliant

.RFA

Panel de control

IVAR

Descargar
IVAR PICV 200-205-210 With PICC 22

PICV 200-205-210 With PICC 22

Valve that keeps the flow rate constant during operation within a certain differential pressure range thanks to a membrane device with a contrast spring. Complete with two pockets G 1/4"F for piezometric sockets (IVAR AVB 10) and with plugs for piezometric sockets and cartridge. PICV 200 (female) connections: G 1"1/2F, G 2"F in compliance with ISO 228/1. PICV 205 (male - flat seal) connections: G 2"M, G 2"1/2M in compliance with ISO 228/1. PICV 210 (with unions) connections: G 1"1/2M, G 2"M in compliance with ISO 228/1 and EN 10226-1. To combine with PICC 22 cartridge. PICC connection: W81x16. Compatible with water or glycol solutions max 30%. Min operating temperature: -20 °C. Max operating temperature: 120 °C. Max operating pressure: 25 bar. Valve material: CW617N brass. Sealing gaskets material: Peroxide EPDM. IVAR PICC 22: 41 flow rate ranges to set even during operation; brass and PSU insert; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets.

IVAR

PICV 200-205-210 With PICC 22

Valve that keeps the flow rate constant during operation within a certain differential pressure range thanks to a membrane device with a contrast spring. Complete with two pockets G 1/4"F for piezometric sockets (IVAR AVB 10) and with plugs for piezometric sockets and cartridge. PICV 200 (female) connections: G 1"1/2F, G 2"F in compliance with ISO 228/1. PICV 205 (male - flat seal) connections: G 2"M, G 2"1/2M in compliance with ISO 228/1. PICV 210 (with unions) connections: G 1"1/2M, G 2"M in compliance with ISO 228/1 and EN 10226-1. To combine with PICC 22 cartridge. PICC connection: W81x16. Compatible with water or glycol solutions max 30%. Min operating temperature: -20 °C. Max operating temperature: 120 °C. Max operating pressure: 25 bar. Valve material: CW617N brass. Sealing gaskets material: Peroxide EPDM. IVAR PICC 22: 41 flow rate ranges to set even during operation; brass and PSU insert; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets.

EMCS compliant

.RFA

Válvula para calefacción y refrigeración

IVAR

Descargar
IVAR PICV 100-105-110 With PICC 11-12-13

PICV 100-105-110 With PICC 11-12-13

Valve that keeps the flow rate constant during operation within a certain differential pressure range thanks to a membrane device with a contrast spring. Complete with two pockets G 1/4"F for piezometric sockets (IVAR AVB 10) and with plugs for piezometric sockets and cartridge. PICV 100 (female) connections: G 1"F, G 1"1/4F in compliance with ISO 228/1. PICV 105 (male - flat seal) connections: G 1"M, G 1"1/4M, G 1"1/2M in compliance with ISO 228/1. PICV 110 (with unions) connections: G 3/4"M, G 1"M, G 1"1/4M in compliance with ISO 228/1 and EN 10226-1. To combine with PICC 11, PICC 12 or PICC 13 cartridges. PICC connection: M54x1.5. Compatible with water or glycol solutions max 30%. Min operating temperature: -20 °C. Max operating temperature: 120 °C. Max operating pressure: 25 bar. Max closing pressure with PICC 13: 4 bar. Valve material: CW617N brass. Sealing gaskets material: Peroxide EPDM. IVAR PICC 11: 8 flow rate ranges to set; brass and POM insert; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets. IVAR PICC 12: 41 flow rate ranges to set even during operation; brass and PSU insert; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets. IVAR PICC 13: 41 flow rate ranges to set even during operation; to combine with IVAR RV 03 axial motor (M30x1.5; 2 points/3 points 230 V AC or 2 points/3 points 24 V AC or proportional 0-10 V 24 V AC adjustment); max closing pressure 4 bar; brass and PSU/POM/PPS (glass-fibre reinforced) insert; stainless steel internal metal components; PPS/Peroxide EPDM cone; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets.

IVAR

PICV 100-105-110 With PICC 11-12-13

Valve that keeps the flow rate constant during operation within a certain differential pressure range thanks to a membrane device with a contrast spring. Complete with two pockets G 1/4"F for piezometric sockets (IVAR AVB 10) and with plugs for piezometric sockets and cartridge. PICV 100 (female) connections: G 1"F, G 1"1/4F in compliance with ISO 228/1. PICV 105 (male - flat seal) connections: G 1"M, G 1"1/4M, G 1"1/2M in compliance with ISO 228/1. PICV 110 (with unions) connections: G 3/4"M, G 1"M, G 1"1/4M in compliance with ISO 228/1 and EN 10226-1. To combine with PICC 11, PICC 12 or PICC 13 cartridges. PICC connection: M54x1.5. Compatible with water or glycol solutions max 30%. Min operating temperature: -20 °C. Max operating temperature: 120 °C. Max operating pressure: 25 bar. Max closing pressure with PICC 13: 4 bar. Valve material: CW617N brass. Sealing gaskets material: Peroxide EPDM. IVAR PICC 11: 8 flow rate ranges to set; brass and POM insert; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets. IVAR PICC 12: 41 flow rate ranges to set even during operation; brass and PSU insert; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets. IVAR PICC 13: 41 flow rate ranges to set even during operation; to combine with IVAR RV 03 axial motor (M30x1.5; 2 points/3 points 230 V AC or 2 points/3 points 24 V AC or proportional 0-10 V 24 V AC adjustment); max closing pressure 4 bar; brass and PSU/POM/PPS (glass-fibre reinforced) insert; stainless steel internal metal components; PPS/Peroxide EPDM cone; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets.

EMCS compliant

.RFA

Válvula para calefacción y refrigeración

IVAR

Descargar
IVAR IVARSAT-L-LE

IVARSAT-L-LE

Satellite module that independently manages low-temperature heating (mixed circuit) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; mixing valve for fixed point mixing (with thermostatic control head and remote contact probe) or outside compensated temperature mixing (with axial servomotor and control unit); three-speed pump / model “E” with variable-speed pump EEI<20; summer/winter two-way valve; pocket for temperature immersion probe on delivery side of primary circuit; balancing valve on primary circuit; balancing by-pass valve on mixed circuit; balancing lockshield of heating/domestic water circuit; hydraulic separator with built-in check valve; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. Model “1” with high-temperature domestic water outlet. Model “R” with hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor.

IVAR

IVARSAT-L-LE

Satellite module that independently manages low-temperature heating (mixed circuit) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; mixing valve for fixed point mixing (with thermostatic control head and remote contact probe) or outside compensated temperature mixing (with axial servomotor and control unit); three-speed pump / model “E” with variable-speed pump EEI<20; summer/winter two-way valve; pocket for temperature immersion probe on delivery side of primary circuit; balancing valve on primary circuit; balancing by-pass valve on mixed circuit; balancing lockshield of heating/domestic water circuit; hydraulic separator with built-in check valve; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. Model “1” with high-temperature domestic water outlet. Model “R” with hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor.

EMCS compliant

.RFA

Distribuidor para calefacción y aire acondicionado

IVAR

Descargar
IVAR IVARSAT-HL-HLE

IVARSAT-HL-HLE

Satellite module that independently manages high-temperature and low-temperature heating (direct and mixed circuits) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; mixing valve for fixed point mixing (with thermostatic control head and remote contact probe) or outside compensated temperature mixing (with axial servomotor and control unit); three-speed pump / model “E” with variable-speed pump EEI<20; summer/winter two-way valve on high-temperature and low-temperature circuits; pocket for temperature immersion probe on delivery side of primary circuit; balancing valve on primary circuit; balancing by-pass valve on mixed circuit; balancing lockshield of heating/domestic water circuit; hydraulic separator with built-in check valve; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. High-temperature domestic water outlet. Hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor.

IVAR

IVARSAT-HL-HLE

Satellite module that independently manages high-temperature and low-temperature heating (direct and mixed circuits) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; mixing valve for fixed point mixing (with thermostatic control head and remote contact probe) or outside compensated temperature mixing (with axial servomotor and control unit); three-speed pump / model “E” with variable-speed pump EEI<20; summer/winter two-way valve on high-temperature and low-temperature circuits; pocket for temperature immersion probe on delivery side of primary circuit; balancing valve on primary circuit; balancing by-pass valve on mixed circuit; balancing lockshield of heating/domestic water circuit; hydraulic separator with built-in check valve; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. High-temperature domestic water outlet. Hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor.

EMCS compliant

.RFA

Distribuidor para calefacción y aire acondicionado

IVAR

Descargar