1,519 BIM collections found from 69 manufacturer(s) in United States Of America
Remeha GAS 310 Eco Pro right

GAS 310 Eco Pro right

Gas boiler, execution right Available output 285, 355, 430, 500, 575 and 650 kW

Remeha

GAS 310 Eco Pro right

Gas boiler, execution right
Available output 285, 355, 430, 500, 575 and 650 kW

EMCS compliant

.DWG .RFA

Boiler

Remeha

Download
Remeha GAS 310 Eco Pro left

GAS 310 Eco Pro left

Gas boiler, execution left Available output 285, 355, 430, 500, 575 and 650 kW

Remeha

GAS 310 Eco Pro left

Gas boiler, execution left
Available output 285, 355, 430, 500, 575 and 650 kW

EMCS compliant

.DWG .RFA

Boiler

Remeha

Download
Watts Industries 15M2

15M2

Water Hammer Arrestor

Watts Industries

15M2

Water Hammer Arrestor

EMCS compliant

.DWG .RFA .IFC

Water Shock Arrestor

Watts Industries

Download
Watts Industries WSA016

WSA016

Water Shock Arrestor

Watts Industries

WSA016

Water Shock Arrestor

EMCS compliant

.DWG .RFA .IFC

Water Shock Arrestor

Watts Industries

Download
NIBE F730

F730

NIBE F730 is an intelligent exhaust air heat pump. NIBE F730 provides heating, ventilation, and hot water efficiently, simply and economically.

NIBE

F730

NIBE F730 is an intelligent exhaust air heat pump. NIBE F730 provides heating, ventilation, and hot water efficiently, simply and economically.

EMCS compliant

.DWG .RFA .IFC

Heat Pump

NIBE

Download
NIBE F750

F750

NIBE F750 is an intelligent exhaust air heat pump. NIBE F750 provides heating, ventilation, heat recovery and hot water efficiently, simply and economically.

NIBE

F750

NIBE F750 is an intelligent exhaust air heat pump. NIBE F750 provides heating, ventilation, heat recovery and hot water efficiently, simply and economically.

EMCS compliant

.DWG .RFA .IFC

Heat Pump

NIBE

Download
Christesen Heizkörper Christesen Heizkörper

Christesen Heizkörper

Content for Trimble Nova is available. Please click here for more information.

Christesen Heizkörper

Christesen Heizkörper

Content for Trimble Nova is available. Please click here for more information.

 

.PDF Nova

Trimble Nova

Christesen Heizkörper

Download
Mitsubishi Electric City Multi PURY-M YNW-A1 R32 (Model 2019)

City Multi PURY-M YNW-A1 R32 (Model 2019)

Heat recovery Outdoor Unit

Mitsubishi Electric

City Multi PURY-M YNW-A1 R32 (Model 2019)

Heat recovery Outdoor Unit

EMCS compliant

.DWG .RFA .IFC

Heat Pump

Mitsubishi Electric

Download
Mitsubishi Electric City Multi PURY-EM YNW-A1 R32 (Model 2019)

City Multi PURY-EM YNW-A1 R32 (Model 2019)

Heat recovery Outdoor Unit

Mitsubishi Electric

City Multi PURY-EM YNW-A1 R32 (Model 2019)

Heat recovery Outdoor Unit

EMCS compliant

.DWG .RFA .IFC

Heat Pump

Mitsubishi Electric

Download
NIBE F1155

F1155

Inverter‑controlled ground source heat pump

NIBE

F1155

Inverter-controlled ground source heat pump

EMCS compliant

.DWG .RFA .IFC

Heat Pump

NIBE

Download
NIBE F1155PC

F1155PC

Inverter‑controlled ground source heat pump

NIBE

F1155PC

Inverter-controlled ground source heat pump

EMCS compliant

.DWG .RFA .IFC

Heat Pump

NIBE

Download
NIBE F2120

F2120

Inverter‑controlled air/water heat pump

NIBE

F2120

Inverter-controlled air/water heat pump

EMCS compliant

.DWG .RFA .IFC

Heat Pump

NIBE

Download
Mitsubishi Heavy Industries Air Conditioning Europe PFD

PFD

PFD refrigerant flow branch control., Easy installation, New PFD design means the connection of the indoor unit liquid pipe is made directly to the liquid line, bypassing the PFD. This means (x2) less pipe connections per indoor unit, reducing installation time and cost., Optional PFD box extension cable that has a connector at ends makes it possible to separate the indoor unit and PFD box further, enable the PFD box to be located away from the indoor unit help reducing the influence of sound caused by PFD box and refrigerant flow.

Mitsubishi Heavy Industries Air Conditioning Europe

PFD

PFD refrigerant flow branch control.
-Easy installation, New PFD design means the connection of the indoor unit liquid pipe is made directly to the liquid line - bypassing the PFD. This means (x2) less pipe connections per indoor unit, reducing installation time and cost.
-Optional PFD box extension cable that has a connector at ends makes it possible to separate the indoor unit and PFD box further, enable the PFD box to be located away from the indoor unit help reducing the influence of sound caused by PFD box and refrigerant flow.

EMCS compliant

.DWG .RFA .IFC

Control Unit for Heating and Cooling

Mitsubishi Heavy Industries Air Conditioning Europe

Download
Mitsubishi Heavy Industries Air Conditioning Europe FDT-KXZE1

FDT-KXZE1

Ceiling Cassette, 4way‑indoor unit, Draft Prevention Panel as an option, Individual flap control system, Drain can be discharged upwards by 850mm from the ceiling surface., Motion Sensor to improve the comfort and energy saving performance of the unit., Component design can acheive better aerodynamic perfromance and lower noise level.

Mitsubishi Heavy Industries Air Conditioning Europe

FDT-KXZE1

Ceiling Cassette -4way-indoor unit
-Draft Prevention Panel as an option
-Individual flap control system
-Drain can be discharged upwards by 850mm from the ceiling surface.
-Motion Sensor to improve the comfort and energy saving performance of the unit.
-Component design can acheive better aerodynamic perfromance and lower noise level.

EMCS compliant

.DWG .RFA .IFC

Air Conditioner

Mitsubishi Heavy Industries Air Conditioning Europe

Download
Rendamax R3601-R3610 EVO

R3601-R3610 EVO

System Boiler

Rendamax

R3601-R3610 EVO

System Boiler

EMCS compliant

.DWG .RFA .IFC

Boiler

Rendamax

Download
Rendamax R3501-R3509 EVO

R3501-R3509 EVO

System Boiler

Rendamax

R3501-R3509 EVO

System Boiler

EMCS compliant

.DWG .RFA .IFC

Boiler

Rendamax

Download
Rendamax R3401-R3410 EVO

R3401-R3410 EVO

System Boiler

Rendamax

R3401-R3410 EVO

System Boiler

EMCS compliant

.DWG .RFA .IFC

Boiler

Rendamax

Download
Rendamax R604-R607 EVO IP

R604-R607 EVO IP

Central, Industrial and Water Heating IP

Rendamax

R604-R607 EVO IP

Central, Industrial and Water Heating IP

EMCS compliant

.DWG .RFA .IFC

Boiler

Rendamax

Download
Rendamax R604-R607 EVO

R604-R607 EVO

Central, Industrial and Water Heating

Rendamax

R604-R607 EVO

Central, Industrial and Water Heating

EMCS compliant

.DWG .RFA .IFC

Boiler

Rendamax

Download
Rendamax R604-R607 EVO IND

R604-R607 EVO IND

Central, Industrial and Water Heating IND

Rendamax

R604-R607 EVO IND

Central, Industrial and Water Heating IND

EMCS compliant

.DWG .RFA .IFC

Boiler

Rendamax

Download
Rendamax R601-R603 EVO IP

R601-R603 EVO IP

Central, Industrial and Water Heating IP

Rendamax

R601-R603 EVO IP

Central, Industrial and Water Heating IP

EMCS compliant

.DWG .RFA .IFC

Boiler

Rendamax

Download
Rendamax R601-R603 EVO

R601-R603 EVO

Central, Industrial and Water Heating

Rendamax

R601-R603 EVO

Central, Industrial and Water Heating

EMCS compliant

.DWG .RFA .IFC

Boiler

Rendamax

Download
Rendamax R601-R603 EVO IND

R601-R603 EVO IND

Central, Industrial and Water Heating IND

Rendamax

R601-R603 EVO IND

Central, Industrial and Water Heating IND

EMCS compliant

.DWG .RFA .IFC

Boiler

Rendamax

Download
IVAR PICV 00-05-10 With PICC 01-02-03

PICV 00-05-10 With PICC 01-02-03

Valve that keeps the flow rate constant during operation within a certain differential pressure range thanks to a membrane device with a contrast spring. Complete with two pockets G 1/4"F for piezometric sockets (IVAR AVB 10) and with plugs for piezometric sockets and cartridge. PICV 00 (female) connections: G 1/2"F, G 3/4"F, G 1"F in compliance with ISO 228/1. PICV 05 (male, flat seal) connections: G 3/4"M, EUROK, G 1"M, G 1"1/4M in compliance with ISO 228/1. PICV 10 (with unions) connections: G 1/2"M, G 3/4"M, G 1"M in compliance with ISO 228/1 and EN 10226‑1. To combine with PICC 01, PICC 02 or PICC 03 cartridges. PICC connection: M32x1.5. Compatible with water or glycol solutions max 30%. Min operating temperature:, 20 °C. Max operating temperature: 120 °C. Max operating pressure: 25 bar. Max closing pressure with PICC 03: 6 bar. Valve material: CW617N brass. Sealing gaskets material: Peroxide EPDM. IVAR PICC 01: 8 flow rate ranges to set; brass and POM insert; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets. IVAR PICC 02: 41 flow rate ranges to set even during operation; brass and PSU insert; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets. IVAR PICC 03: 41 flow rate ranges to set even during operation; to combine with IVAR TE 3003 electrothermal actuator (M30x1.5; ON/OFF 230 V AC or ON/OFF 24 V AC or proportional 0‑10 V 24 V AC adjustment) or IVAR RV 03 axial motor (M30x1.5; 2 points/3 points 230 V AC or 2 points/3 points 24 V AC or proportional 0‑10 V 24 V AC adjustment); max closing pressure 6 bar; brass and PSU/POM/PPS (glass‑fibre reinforced) insert; stainless steel internal metal components; PPS/Peroxide EPDM cone; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets.

IVAR

PICV 00-05-10 With PICC 01-02-03

Valve that keeps the flow rate constant during operation within a certain differential pressure range thanks to a membrane device with a contrast spring. Complete with two pockets G 1/4"F for piezometric sockets (IVAR AVB 10) and with plugs for piezometric sockets and cartridge. PICV 00 (female) connections: G 1/2"F, G 3/4"F, G 1"F in compliance with ISO 228/1. PICV 05 (male - flat seal) connections: G 3/4"M, EUROK, G 1"M, G 1"1/4M in compliance with ISO 228/1. PICV 10 (with unions) connections: G 1/2"M, G 3/4"M, G 1"M in compliance with ISO 228/1 and EN 10226-1. To combine with PICC 01, PICC 02 or PICC 03 cartridges. PICC connection: M32x1.5. Compatible with water or glycol solutions max 30%. Min operating temperature: -20 °C. Max operating temperature: 120 °C. Max operating pressure: 25 bar. Max closing pressure with PICC 03: 6 bar. Valve material: CW617N brass. Sealing gaskets material: Peroxide EPDM. IVAR PICC 01: 8 flow rate ranges to set; brass and POM insert; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets. IVAR PICC 02: 41 flow rate ranges to set even during operation; brass and PSU insert; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets. IVAR PICC 03: 41 flow rate ranges to set even during operation; to combine with IVAR TE 3003 electrothermal actuator (M30x1.5; ON/OFF 230 V AC or ON/OFF 24 V AC or proportional 0-10 V 24 V AC adjustment) or IVAR RV 03 axial motor (M30x1.5; 2 points/3 points 230 V AC or 2 points/3 points 24 V AC or proportional 0-10 V 24 V AC adjustment); max closing pressure 6 bar; brass and PSU/POM/PPS (glass-fibre reinforced) insert; stainless steel internal metal components; PPS/Peroxide EPDM cone; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets.

EMCS compliant

.RFA

Valve for Heating and Cooling

IVAR

Download
IVAR PICV 200-205-210 With PICC 22

PICV 200-205-210 With PICC 22

Valve that keeps the flow rate constant during operation within a certain differential pressure range thanks to a membrane device with a contrast spring. Complete with two pockets G 1/4"F for piezometric sockets (IVAR AVB 10) and with plugs for piezometric sockets and cartridge. PICV 200 (female) connections: G 1"1/2F, G 2"F in compliance with ISO 228/1. PICV 205 (male, flat seal) connections: G 2"M, G 2"1/2M in compliance with ISO 228/1. PICV 210 (with unions) connections: G 1"1/2M, G 2"M in compliance with ISO 228/1 and EN 10226‑1. To combine with PICC 22 cartridge. PICC connection: W81x16. Compatible with water or glycol solutions max 30%. Min operating temperature:, 20 °C. Max operating temperature: 120 °C. Max operating pressure: 25 bar. Valve material: CW617N brass. Sealing gaskets material: Peroxide EPDM. IVAR PICC 22: 41 flow rate ranges to set even during operation; brass and PSU insert; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets.

IVAR

PICV 200-205-210 With PICC 22

Valve that keeps the flow rate constant during operation within a certain differential pressure range thanks to a membrane device with a contrast spring. Complete with two pockets G 1/4"F for piezometric sockets (IVAR AVB 10) and with plugs for piezometric sockets and cartridge. PICV 200 (female) connections: G 1"1/2F, G 2"F in compliance with ISO 228/1. PICV 205 (male - flat seal) connections: G 2"M, G 2"1/2M in compliance with ISO 228/1. PICV 210 (with unions) connections: G 1"1/2M, G 2"M in compliance with ISO 228/1 and EN 10226-1. To combine with PICC 22 cartridge. PICC connection: W81x16. Compatible with water or glycol solutions max 30%. Min operating temperature: -20 °C. Max operating temperature: 120 °C. Max operating pressure: 25 bar. Valve material: CW617N brass. Sealing gaskets material: Peroxide EPDM. IVAR PICC 22: 41 flow rate ranges to set even during operation; brass and PSU insert; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets.

EMCS compliant

.RFA

Valve for Heating and Cooling

IVAR

Download
IVAR PICV 100-105-110 With PICC 11-12-13

PICV 100-105-110 With PICC 11-12-13

Valve that keeps the flow rate constant during operation within a certain differential pressure range thanks to a membrane device with a contrast spring. Complete with two pockets G 1/4"F for piezometric sockets (IVAR AVB 10) and with plugs for piezometric sockets and cartridge. PICV 100 (female) connections: G 1"F, G 1"1/4F in compliance with ISO 228/1. PICV 105 (male, flat seal) connections: G 1"M, G 1"1/4M, G 1"1/2M in compliance with ISO 228/1. PICV 110 (with unions) connections: G 3/4"M, G 1"M, G 1"1/4M in compliance with ISO 228/1 and EN 10226‑1. To combine with PICC 11, PICC 12 or PICC 13 cartridges. PICC connection: M54x1.5. Compatible with water or glycol solutions max 30%. Min operating temperature:, 20 °C. Max operating temperature: 120 °C. Max operating pressure: 25 bar. Max closing pressure with PICC 13: 4 bar. Valve material: CW617N brass. Sealing gaskets material: Peroxide EPDM. IVAR PICC 11: 8 flow rate ranges to set; brass and POM insert; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets. IVAR PICC 12: 41 flow rate ranges to set even during operation; brass and PSU insert; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets. IVAR PICC 13: 41 flow rate ranges to set even during operation; to combine with IVAR RV 03 axial motor (M30x1.5; 2 points/3 points 230 V AC or 2 points/3 points 24 V AC or proportional 0‑10 V 24 V AC adjustment); max closing pressure 4 bar; brass and PSU/POM/PPS (glass‑fibre reinforced) insert; stainless steel internal metal components; PPS/Peroxide EPDM cone; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets.

IVAR

PICV 100-105-110 With PICC 11-12-13

Valve that keeps the flow rate constant during operation within a certain differential pressure range thanks to a membrane device with a contrast spring. Complete with two pockets G 1/4"F for piezometric sockets (IVAR AVB 10) and with plugs for piezometric sockets and cartridge. PICV 100 (female) connections: G 1"F, G 1"1/4F in compliance with ISO 228/1. PICV 105 (male - flat seal) connections: G 1"M, G 1"1/4M, G 1"1/2M in compliance with ISO 228/1. PICV 110 (with unions) connections: G 3/4"M, G 1"M, G 1"1/4M in compliance with ISO 228/1 and EN 10226-1. To combine with PICC 11, PICC 12 or PICC 13 cartridges. PICC connection: M54x1.5. Compatible with water or glycol solutions max 30%. Min operating temperature: -20 °C. Max operating temperature: 120 °C. Max operating pressure: 25 bar. Max closing pressure with PICC 13: 4 bar. Valve material: CW617N brass. Sealing gaskets material: Peroxide EPDM. IVAR PICC 11: 8 flow rate ranges to set; brass and POM insert; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets. IVAR PICC 12: 41 flow rate ranges to set even during operation; brass and PSU insert; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets. IVAR PICC 13: 41 flow rate ranges to set even during operation; to combine with IVAR RV 03 axial motor (M30x1.5; 2 points/3 points 230 V AC or 2 points/3 points 24 V AC or proportional 0-10 V 24 V AC adjustment); max closing pressure 4 bar; brass and PSU/POM/PPS (glass-fibre reinforced) insert; stainless steel internal metal components; PPS/Peroxide EPDM cone; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets.

EMCS compliant

.RFA

Valve for Heating and Cooling

IVAR

Download
IVAR IVARSAT-L-LE

IVARSAT-L-LE

Satellite module that independently manages low‑temperature heating (mixed circuit) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti‑scalding thermostatic mixing valve 36÷50 °C; anti‑scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti‑pollution check valve at the inlet of domestic cold water circuit; mixing valve for fixed point mixing (with thermostatic control head and remote contact probe) or outside compensated temperature mixing (with axial servomotor and control unit); three‑speed pump / model “E” with variable‑speed pump EEI<20; summer/winter two‑way valve; pocket for temperature immersion probe on delivery side of primary circuit; balancing valve on primary circuit; balancing by‑pass valve on mixed circuit; balancing lockshield of heating/domestic water circuit; hydraulic separator with built‑in check valve; shut‑off ball valve; manual air vent valve; fill‑drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. Model “1” with high‑temperature domestic water outlet. Model “R” with hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet‑metal cover (white painted) 860‑960 × 700 × 110‑160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1, 5 o 2, 5 m3/h, cold domestic water flow meter 1, 5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor.

IVAR

IVARSAT-L-LE

Satellite module that independently manages low-temperature heating (mixed circuit) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; mixing valve for fixed point mixing (with thermostatic control head and remote contact probe) or outside compensated temperature mixing (with axial servomotor and control unit); three-speed pump / model “E” with variable-speed pump EEI<20; summer/winter two-way valve; pocket for temperature immersion probe on delivery side of primary circuit; balancing valve on primary circuit; balancing by-pass valve on mixed circuit; balancing lockshield of heating/domestic water circuit; hydraulic separator with built-in check valve; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. Model “1” with high-temperature domestic water outlet. Model “R” with hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor.

EMCS compliant

.RFA

Distributor for Heating and Cooling

IVAR

Download
IVAR IVARSAT-HL-HLE

IVARSAT-HL-HLE

Satellite module that independently manages high‑temperature and low‑temperature heating (direct and mixed circuits) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti‑scalding thermostatic mixing valve 36÷50 °C; anti‑scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti‑pollution check valve at the inlet of domestic cold water circuit; mixing valve for fixed point mixing (with thermostatic control head and remote contact probe) or outside compensated temperature mixing (with axial servomotor and control unit); three‑speed pump / model “E” with variable‑speed pump EEI<20; summer/winter two‑way valve on high‑temperature and low‑temperature circuits; pocket for temperature immersion probe on delivery side of primary circuit; balancing valve on primary circuit; balancing by‑pass valve on mixed circuit; balancing lockshield of heating/domestic water circuit; hydraulic separator with built‑in check valve; shut‑off ball valve; manual air vent valve; fill‑drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. High‑temperature domestic water outlet. Hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet‑metal cover (white painted) 860‑960 × 700 × 110‑160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1, 5 o 2, 5 m3/h, cold domestic water flow meter 1, 5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor.

IVAR

IVARSAT-HL-HLE

Satellite module that independently manages high-temperature and low-temperature heating (direct and mixed circuits) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; mixing valve for fixed point mixing (with thermostatic control head and remote contact probe) or outside compensated temperature mixing (with axial servomotor and control unit); three-speed pump / model “E” with variable-speed pump EEI<20; summer/winter two-way valve on high-temperature and low-temperature circuits; pocket for temperature immersion probe on delivery side of primary circuit; balancing valve on primary circuit; balancing by-pass valve on mixed circuit; balancing lockshield of heating/domestic water circuit; hydraulic separator with built-in check valve; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. High-temperature domestic water outlet. Hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor.

EMCS compliant

.RFA

Distributor for Heating and Cooling

IVAR

Download
IVAR IVARSAT-H

IVARSAT-H

Satellite module that independently manages high‑temperature heating (direct circuit) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti‑scalding thermostatic mixing valve 36÷50 °C; domestic water preheating device; anti‑scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti‑pollution check valve at the inlet of domestic cold water circuit; summer/winter two‑way valve; pocket for temperature immersion probe on delivery side of primary circuit; balancing lockshield of primary circuit with double micrometrical adjustment; balancing lockshield of heating/domestic water circuit; differential overpressure by‑pass valve on primary circuit; shut‑off ball valve; manual air vent valve; fill‑drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. Model “1” with high‑temperature domestic water outlet. Model “R” with hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet‑metal cover (white painted) 860‑960 × 700 × 110‑160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1, 5 o 2, 5 m3/h, cold domestic water flow meter 1, 5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor.

IVAR

IVARSAT-H

Satellite module that independently manages high-temperature heating (direct circuit) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; domestic water preheating device; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; summer/winter two-way valve; pocket for temperature immersion probe on delivery side of primary circuit; balancing lockshield of primary circuit with double micrometrical adjustment; balancing lockshield of heating/domestic water circuit; differential overpressure by-pass valve on primary circuit; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. Model “1” with high-temperature domestic water outlet. Model “R” with hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor.

EMCS compliant

.RFA

Distributor for Heating and Cooling

IVAR

Download
IVAR IVARSAT-H VNR

IVARSAT-H VNR

Satellite module that independently manages high‑temperature heating (direct circuit) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti‑scalding thermostatic mixing valve 36÷50 °C; domestic water preheating device; anti‑scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti‑pollution check valve at the inlet of domestic cold water circuit; summer/winter two‑way valve; pocket for temperature immersion probe on delivery side of primary circuit; balancing lockshield of primary circuit with double micrometrical adjustment; balancing lockshield of heating/domestic water circuit; differential overpressure by‑pass valve on primary circuit; shut‑off ball valve; manual air vent valve; fill‑drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. Model “1” with high‑temperature domestic water outlet. Model “R” with hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet‑metal cover (white painted) 860‑960 × 700 × 110‑160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1, 5 o 2, 5 m3/h, cold domestic water flow meter 1, 5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor. In compliance with Belgaqua.

IVAR

IVARSAT-H VNR

Satellite module that independently manages high-temperature heating (direct circuit) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; domestic water preheating device; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; summer/winter two-way valve; pocket for temperature immersion probe on delivery side of primary circuit; balancing lockshield of primary circuit with double micrometrical adjustment; balancing lockshield of heating/domestic water circuit; differential overpressure by-pass valve on primary circuit; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. Model “1” with high-temperature domestic water outlet. Model “R” with hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor. In compliance with Belgaqua.

EMCS compliant

.RFA

Distributor for Heating and Cooling

IVAR

Download
ABB ClimaEco Room temperature controller control element

ClimaEco Room temperature controller control element

SAR/A1.0.1‑24 RT‑control element

ABB

ClimaEco Room temperature controller control element

SAR/A1.0.1-24 RT-control element

EMCS compliant

.DWG .RFA .IFC

Control Unit for Heating and Cooling

ABB

Download
ABB ClimaEco Room Temperature Controller, 6-fold

ClimaEco Room Temperature Controller, 6-fold

SBC/U6.0.1‑84 HVAC/Co2‑device, 6f. CE

ABB

ClimaEco Room Temperature Controller, 6-fold

SBC/U6.0.1-84 HVAC/Co2-device, 6f. CE

EMCS compliant

.DWG .RFA .IFC

Control Unit for Heating and Cooling

ABB

Download
ABB ClimaEco Room temperature controller and FanCoil control element

ClimaEco Room temperature controller and FanCoil control element

SAF/A1.0.1‑24 HVAC‑control element

ABB

ClimaEco Room temperature controller and FanCoil control element

SAF/A1.0.1-24 HVAC-control element

EMCS compliant

.DWG .RFA .IFC

Control Unit for Heating and Cooling

ABB

Download
ABB ClimaEco Room Temperature Controller, 10-fold

ClimaEco Room Temperature Controller, 10-fold

SBC/U10.0.1‑84 HVAC/Co2‑device, 10f. CE

ABB

ClimaEco Room Temperature Controller, 10-fold

SBC/U10.0.1-84 HVAC/Co2-device, 10f. CE

EMCS compliant

.DWG .RFA .IFC

Control Unit for Heating and Cooling

ABB

Download
ABB ClimaEco Control element, 12-fold

ClimaEco Control element, 12-fold

SB/U12.0.1‑84 12f. Control element

ABB

ClimaEco Control element, 12-fold

SB/U12.0.1-84 12f. Control element

EMCS compliant

.DWG .RFA .IFC

Control Unit for Heating and Cooling

ABB

Download
ABB Room Temperature Controller FanCoil with Display

Room Temperature Controller FanCoil with Display

RTR Fan Coil with Display, AP

ABB

Room Temperature Controller FanCoil with Display

RTR Fan Coil with Display, AP

EMCS compliant

.DWG .RFA .IFC

Control Unit for Heating and Cooling

ABB

Download
ABB ClimaEco Control element, 8-fold

ClimaEco Control element, 8-fold

SB/U8.0.1‑84 8f. Control element

ABB

ClimaEco Control element, 8-fold

SB/U8.0.1-84 8f. Control element

EMCS compliant

.DWG .RFA .IFC

Control Unit for Heating and Cooling

ABB

Download
Mitsubishi Electric City Multi PLFY-WP-VFM

City Multi PLFY-WP-VFM

4‑way blow ceiling cassette indoor unit

Mitsubishi Electric

City Multi PLFY-WP-VFM

4-way blow ceiling cassette indoor unit

EMCS compliant

.DWG .RFA .IFC

Air Conditioner

Mitsubishi Electric

Download
Ecoforest AU12

AU12

AU12

Ecoforest

AU12

AU12

EMCS compliant

.RFA

Control Unit for Heating and Cooling

Ecoforest

Download
Ecoforest ecoGEOCompact C 5-22kW

ecoGEOCompact C 5-22kW

ecoGEOCompact C 5‑22kW

Ecoforest

ecoGEOCompact C 5-22kW

ecoGEOCompact C 5-22kW

EMCS compliant

.RFA

Heat Pump

Ecoforest

Download
Ecoforest ecoGEOCompact C 3-12kW

ecoGEOCompact C 3-12kW

ecoGEOCompact C 3‑12kW

Ecoforest

ecoGEOCompact C 3-12kW

ecoGEOCompact C 3-12kW

EMCS compliant

.RFA

Heat Pump

Ecoforest

Download
Ecoforest ecoGEOCompact C 1-9kW

ecoGEOCompact C 1-9kW

ecoGEOCompact C 1‑9kW

Ecoforest

ecoGEOCompact C 1-9kW

ecoGEOCompact C 1-9kW

EMCS compliant

.RFA

Heat Pump

Ecoforest

Download
Ecoforest ecoGEO HP 25-100kW

ecoGEO HP 25-100kW

ecoGEO HP 25‑100kW

Ecoforest

ecoGEO HP 25-100kW

ecoGEO HP 25-100kW

EMCS compliant

.RFA

Heat Pump

Ecoforest

Download
Ecoforest ecoGEO HP 15-70kW

ecoGEO HP 15-70kW

ecoGEO HP 15‑70kW

Ecoforest

ecoGEO HP 15-70kW

ecoGEO HP 15-70kW

EMCS compliant

.RFA

Heat Pump

Ecoforest

Download
Ecoforest ecoGEO HP 12-40kW

ecoGEO HP 12-40kW

ecoGEO HP 12‑40kW

Ecoforest

ecoGEO HP 12-40kW

ecoGEO HP 12-40kW

EMCS compliant

.RFA

Heat Pump

Ecoforest

Download
Ecoforest ecoGEO Basic B 5-22kW

ecoGEO Basic B 5-22kW

ecoGEO Basic B 5‑22kW

Ecoforest

ecoGEO Basic B 5-22kW

ecoGEO Basic B 5-22kW

EMCS compliant

.RFA

Heat Pump

Ecoforest

Download
Ecoforest ecoGEO Basic B 3-12kW

ecoGEO Basic B 3-12kW

ecoGEO Basic B 3‑12kW

Ecoforest

ecoGEO Basic B 3-12kW

ecoGEO Basic B 3-12kW

EMCS compliant

.RFA

Heat Pump

Ecoforest

Download
Ecoforest ecoGEO Basic B 1-9kW

ecoGEO Basic B 1-9kW

ecoGEO Basic 1‑9kW

Ecoforest

ecoGEO Basic B 1-9kW

ecoGEO Basic 1-9kW

EMCS compliant

.RFA

Heat Pump

Ecoforest

Download
Mitsubishi Electric City Multi PURY-M YNW-A R32 (Model 2019)

City Multi PURY-M YNW-A R32 (Model 2019)

Heat recovery Outdoor Unit

Mitsubishi Electric

City Multi PURY-M YNW-A R32 (Model 2019)

Heat recovery Outdoor Unit

EMCS compliant

.DWG .RFA .IFC

Heat Pump

Mitsubishi Electric

Download
Mitsubishi Electric City Multi PURY-EM YNW-A R32 (Model 2019)

City Multi PURY-EM YNW-A R32 (Model 2019)

Heat recovery Outdoor Unit

Mitsubishi Electric

City Multi PURY-EM YNW-A R32 (Model 2019)

Heat recovery Outdoor Unit

EMCS compliant

.DWG .RFA .IFC

Heat Pump

Mitsubishi Electric

Download
IVAR Dirtstop®

Dirtstop®

Swivelling magnetic dirt separator with double filtering action, compact, with connection kit for the installation under the boiler. The double filtering action, guaranteed in any position thanks to the swiveling insert (Patent Pending), is performed by a neodymium magnet (magnetic induction B = 1, 2 T (12.000 G)) and a mesh strainer (800 μm) made of AISI 304 stainless steel. The neodymium magnet is diametrically polarized and therefore it develops a homogeneous magnetic field which maximizes the capture of ferrous impurities. The mesh strainer retains all impurities. Impurities precipitate into the large settling chamber at the bottom of the dirt separator. The evacuation of impurities is possible without emptying the system and disassembling the dirt separator, thanks to the removable magnet and to the opening of a 360° swiveling shut‑off ball valve. Body material: technopolymer IXEF®. Shut‑off ball valve, swiveling fitting and plugs material: CW617N brass. Sealing elements material: Peroxide EPDM. Temperature: 0 ÷ 90 °C. Max pressure: 3 bars. Kv with swiveling insert in position A = 5, 6 m3/h angle configuration; Kv with swiveling insert in position A1 = 6, 2 m3/h straight configuration; Kv with swiveling insert in position B = 5, 5 m3/h angle configuration; Kv with swiveling insert in position B1 =5, 7 m3/h straight configuration. Compatible with water or glycol solutions max 50%. Connections: 3/4”M x 3/4"F.

IVAR

Dirtstop®

Swivelling magnetic dirt separator with double filtering action, compact, with connection kit for the installation under the boiler. The double filtering action, guaranteed in any position thanks to the swiveling insert (Patent Pending), is performed by a neodymium magnet (magnetic induction B = 1,2 T (12.000 G)) and a mesh strainer (800 μm) made of AISI 304 stainless steel. The neodymium magnet is diametrically polarized and therefore it develops a homogeneous magnetic field which maximizes the capture of ferrous impurities. The mesh strainer retains all impurities. Impurities precipitate into the large settling chamber at the bottom of the dirt separator. The evacuation of impurities is possible without emptying the system and disassembling the dirt separator, thanks to the removable magnet and to the opening of a 360° swiveling shut-off ball valve. Body material: technopolymer IXEF®. Shut-off ball valve, swiveling fitting and plugs material: CW617N brass. Sealing elements material: Peroxide EPDM. Temperature: 0 ÷ 90 °C. Max pressure: 3 bars. Kv with swiveling insert in position A = 5,6 m3/h angle configuration; Kv with swiveling insert in position A1 = 6,2 m3/h straight configuration; Kv with swiveling insert in position B = 5,5 m3/h angle configuration; Kv with swiveling insert in position B1 =5,7 m3/h straight configuration. Compatible with water or glycol solutions max 50%. Connections: 3/4”M x 3/4"F.

EMCS compliant

.RFA

Control Unit for Heating and Cooling

IVAR

Download
IVAR VCR 2132 NH HARMONIA Thermostatic valve

VCR 2132 NH HARMONIA Thermostatic valve

Reverse thermostatic valve with flow rate pre‑regulation and pressure dynamic balancing, HARMONIA‑series, with female connection. Connection to iron pipe x Connection to radiator: G 3/8"F x G 3/8"M with or without O‑ring, G 1/2"F x G 1/2"M with or without O‑ring. Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol‑water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Differential pressure range: 0.1÷0.6 bar. Body material: nickel‑plated CW617N brass. Gaskets and O‑rings materials: Peroxide EPDM. Spring, washer and spindle material: Stainless steel. Protective cap: orange ABS.

IVAR

VCR 2132 NH HARMONIA Thermostatic valve

Reverse thermostatic valve with flow rate pre-regulation and pressure dynamic balancing, HARMONIA-series, with female connection. Connection to iron pipe x Connection to radiator: G 3/8"F x G 3/8"M with or without O-ring, G 1/2"F x G 1/2"M with or without O-ring. Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol-water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Differential pressure range: 0.1÷0.6 bar. Body material: nickel-plated CW617N brass. Gaskets and O-rings materials: Peroxide EPDM. Spring, washer and spindle material: Stainless steel. Protective cap: orange ABS.

EMCS compliant

.RFA

Valve for Heating and Cooling

IVAR

Download
IVAR VS 2102 NH HARMONIA Thermostatic valve

VS 2102 NH HARMONIA Thermostatic valve

Angle thermostatic valve with flow rate pre‑regulation and pressure dynamic balancing, HARMONIA‑series, with female connection. Connection to iron pipe x Connection to radiator: 3/8"F x 3/8"M with or without O‑ring, 1/2"F x 1/2"M with or without O‑ring. Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol‑water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Differential pressure range: 0.1÷0.6 bar. Body material: nickel‑plated CW617N brass. Gaskets and O‑rings materials: Peroxide EPDM. Spring, washer and spindle material: Stainless steel. Protective cap: orange ABS.

IVAR

VS 2102 NH HARMONIA Thermostatic valve

Angle thermostatic valve with flow rate pre-regulation and pressure dynamic balancing, HARMONIA-series, with female connection. Connection to iron pipe x Connection to radiator: 3/8"F x 3/8"M with or without O-ring, 1/2"F x 1/2"M with or without O-ring. Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol-water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Differential pressure range: 0.1÷0.6 bar. Body material: nickel-plated CW617N brass. Gaskets and O-rings materials: Peroxide EPDM. Spring, washer and spindle material: Stainless steel. Protective cap: orange ABS.

EMCS compliant

.RFA

Valve for Heating and Cooling

IVAR

Download
IVAR VD 2105 NH HARMONIA Thermostatic valve

VD 2105 NH HARMONIA Thermostatic valve

Straight thermostatic valve with flow rate pre‑regulation and pressure dynamic balancing, HARMONIA‑series, with male connection. Connection to iron pipe x Connection to radiator: EUROK x 1/2"M with or without O‑ring. Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol‑water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Differential pressure range: 0.1÷0.6 bar. Body material: nickel‑plated CW617N brass. Gaskets and O‑rings materials: Peroxide EPDM. Spring, washer and spindle material: Stainless steel. Protective cap: orange ABS.

IVAR

VD 2105 NH HARMONIA Thermostatic valve

Straight thermostatic valve with flow rate pre-regulation and pressure dynamic balancing, HARMONIA-series, with male connection. Connection to iron pipe x Connection to radiator: EUROK x 1/2"M with or without O-ring. Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol-water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Differential pressure range: 0.1÷0.6 bar. Body material: nickel-plated CW617N brass. Gaskets and O-rings materials: Peroxide EPDM. Spring, washer and spindle material: Stainless steel. Protective cap: orange ABS.

EMCS compliant

.RFA

Valve for Heating and Cooling

IVAR

Download
IVAR VCR 2136 NH HARMONIA Thermostatic valve

VCR 2136 NH HARMONIA Thermostatic valve

Reverse thermostatic valve with flow rate pre‑regulation and pressure dynamic balancing, HARMONIA‑series, with male connection. Connection to iron pipe x Connection to radiator: EUROK x 1/2"M with or without O‑ring. Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol‑water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Differential pressure range: 0.1÷0.6 bar. Body material: nickel‑plated CW617N brass. Gaskets and O‑rings materials: Peroxide EPDM. Spring, washer and spindle material: Stainless steel. Protective cap: orange ABS.

IVAR

VCR 2136 NH HARMONIA Thermostatic valve

Reverse thermostatic valve with flow rate pre-regulation and pressure dynamic balancing, HARMONIA-series, with male connection. Connection to iron pipe x Connection to radiator: EUROK x 1/2"M with or without O-ring. Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol-water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Differential pressure range: 0.1÷0.6 bar. Body material: nickel-plated CW617N brass. Gaskets and O-rings materials: Peroxide EPDM. Spring, washer and spindle material: Stainless steel. Protective cap: orange ABS.

EMCS compliant

.RFA

Valve for Heating and Cooling

IVAR

Download
IVAR VD 2101 NH HARMONIA Thermostatic valve

VD 2101 NH HARMONIA Thermostatic valve

Straight thermostatic valve with flow rate pre‑regulation and pressure dynamic balancing, HARMONIA‑series, with female connection. Connection to iron pipe x Connection to radiator: 3/8"F x 3/8"M with or without O‑ring, 1/2"F x 1/2"M with or without O‑ring. Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol‑water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Differential pressure range: 0.1÷0.6 bar. Body material: nickel‑plated CW617N brass. Gaskets and O‑rings materials: Peroxide EPDM. Spring, washer and spindle material: Stainless steel. Protective cap: orange ABS.

IVAR

VD 2101 NH HARMONIA Thermostatic valve

Straight thermostatic valve with flow rate pre-regulation and pressure dynamic balancing, HARMONIA-series, with female connection. Connection to iron pipe x Connection to radiator: 3/8"F x 3/8"M with or without O-ring, 1/2"F x 1/2"M with or without O-ring. Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol-water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Differential pressure range: 0.1÷0.6 bar. Body material: nickel-plated CW617N brass. Gaskets and O-rings materials: Peroxide EPDM. Spring, washer and spindle material: Stainless steel. Protective cap: orange ABS.

EMCS compliant

.RFA

Valve for Heating and Cooling

IVAR

Download
IVAR VCS 2162 NH SX – VCD 2162 NH DX HARMONIA Thermostatic valve

VCS 2162 NH SX – VCD 2162 NH DX HARMONIA Thermostatic valve

Co‑axial left/right thermostatic valve with flow rate pre‑regulation and pressure dynamic balancing, HARMONIA‑series, with female connection. Connection to iron pipe x Connection to radiator: 3/8"F x 3/8"M with or without O‑ring, 1/2"F x 1/2"M with or without O‑ring. Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol‑water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Differential pressure range: 0.1÷0.6 bar. Body material: nickel‑plated CW617N brass. Gaskets and O‑rings materials: Peroxide EPDM. Spring, washer and spindle material: Stainless steel. Protective cap: orange ABS.

IVAR

VCS 2162 NH SX – VCD 2162 NH DX HARMONIA Thermostatic valve

Co-axial left/right thermostatic valve with flow rate pre-regulation and pressure dynamic balancing, HARMONIA-series, with female connection. Connection to iron pipe x Connection to radiator: 3/8"F x 3/8"M with or without O-ring, 1/2"F x 1/2"M with or without O-ring. Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol-water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Differential pressure range: 0.1÷0.6 bar. Body material: nickel-plated CW617N brass. Gaskets and O-rings materials: Peroxide EPDM. Spring, washer and spindle material: Stainless steel. Protective cap: orange ABS.

EMCS compliant

.RFA

Valve for Heating and Cooling

IVAR

Download
IVAR VCS 2166 NH SX – VCD 2166 NH DX HARMONIA Thermostatic valve

VCS 2166 NH SX – VCD 2166 NH DX HARMONIA Thermostatic valve

Co‑axial left/right thermostatic valve with flow rate pre‑regulation and pressure dynamic balancing, HARMONIA‑series, with male connection. Connection to iron pipe x Connection to radiator: EUROK x 1/2"M with or without O‑ring. Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol‑water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Differential pressure range: 0.1÷0.6 bar. Body material: nickel‑plated CW617N brass. Gaskets and O‑rings materials: Peroxide EPDM. Spring, washer and spindle material: Stainless steel. Protective cap: orange ABS.

IVAR

VCS 2166 NH SX – VCD 2166 NH DX HARMONIA Thermostatic valve

Co-axial left/right thermostatic valve with flow rate pre-regulation and pressure dynamic balancing, HARMONIA-series, with male connection. Connection to iron pipe x Connection to radiator: EUROK x 1/2"M with or without O-ring. Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol-water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Differential pressure range: 0.1÷0.6 bar. Body material: nickel-plated CW617N brass. Gaskets and O-rings materials: Peroxide EPDM. Spring, washer and spindle material: Stainless steel. Protective cap: orange ABS.

EMCS compliant

.RFA

Valve for Heating and Cooling

IVAR

Download
IVAR VS 2106 NH HARMONIA Thermostatic valve

VS 2106 NH HARMONIA Thermostatic valve

Angle thermostatic valve with flow rate pre‑regulation and pressure dynamic balancing, HARMONIA‑series, with male connection. Connection to iron pipe x Connection to radiator: EUROK x 1/2"M with or without O‑ring. Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol‑water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Differential pressure range: 0.1÷0.6 bar. Body material: nickel‑plated CW617N brass. Gaskets and O‑rings materials: Peroxide EPDM. Spring, washer and spindle material: Stainless steel. Protective cap: orange ABS.

IVAR

VS 2106 NH HARMONIA Thermostatic valve

Angle thermostatic valve with flow rate pre-regulation and pressure dynamic balancing, HARMONIA-series, with male connection. Connection to iron pipe x Connection to radiator: EUROK x 1/2"M with or without O-ring. Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol-water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Differential pressure range: 0.1÷0.6 bar. Body material: nickel-plated CW617N brass. Gaskets and O-rings materials: Peroxide EPDM. Spring, washer and spindle material: Stainless steel. Protective cap: orange ABS.

EMCS compliant

.RFA

Valve for Heating and Cooling

IVAR

Download
IVAR VD 2101 Thermostatic valve

VD 2101 Thermostatic valve

Straight thermostatic valve with female connection. Connection to iron pipe x Connection to radiator: G 3/8"F x G 3/8"M with or without O‑ring (with white protective cap or manual head), G 1/2"F x G 1/2"M with or without O‑ring (with white protective cap or manual head), G 3/4"F x G 3/4"M with or without O‑ring (with white protective cap or manual head), G 1"F x G 1"M with or without O‑ring (with white protective cap), G 1"1/4F x G 1"1/4M with or without O‑ring (with white protective cap). Flow rate pre‑regulation only available for 3/8", 1/2" and 3/4" sizes: N‑series (black protective cap or white manual head) or F‑series (red protective cap or white manual head). Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol‑water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Max differential pressure: 1 bar. Max differential pressure with thermostatic head installed: 0.25 bar. Body material: nickel‑plated CW617N brass. Gaskets and O‑rings materials: peroxide EPDM. Spring, washer and spindle material: stainless steel. Protective cap and manual head material: ABS.

IVAR

VD 2101 Thermostatic valve

Straight thermostatic valve with female connection. Connection to iron pipe x Connection to radiator: G 3/8"F x G 3/8"M with or without O-ring (with white protective cap or manual head), G 1/2"F x G 1/2"M with or without O-ring (with white protective cap or manual head), G 3/4"F x G 3/4"M with or without O-ring (with white protective cap or manual head), G 1"F x G 1"M with or without O-ring (with white protective cap), G 1"1/4F x G 1"1/4M with or without O-ring (with white protective cap). Flow rate pre-regulation only available for 3/8", 1/2" and 3/4" sizes: N-series (black protective cap or white manual head) or F-series (red protective cap or white manual head). Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol-water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Max differential pressure: 1 bar. Max differential pressure with thermostatic head installed: 0.25 bar. Body material: nickel-plated CW617N brass. Gaskets and O-rings materials: peroxide EPDM. Spring, washer and spindle material: stainless steel. Protective cap and manual head material: ABS.

EMCS compliant

.RFA

Control Unit for Heating and Cooling

IVAR

Download
IVAR VS 2102 Thermostatic valve

VS 2102 Thermostatic valve

Angle thermostatic valve with female connection. Connection to iron pipe x Connection to radiator: G 3/8"F x G 3/8"M with or without O‑ring (with white protective cap or manual head), G 1/2"F x G 1/2"M with or without O‑ring (with white protective cap or manual head), G 3/4"F x G 3/4"M with or without O‑ring (with white protective cap or manual head), G 1"F x G 1"M with or without O‑ring (with white protective cap), G 1"1/4F x G 1"1/4M with or without O‑ring (with white protective cap). Flow rate pre‑regulation only available for 3/8", 1/2" and 3/4" sizes: N‑series (black protective cap or white manual head) or F‑series (red protective cap or white manual head). Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol‑water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Max differential pressure: 1 bar. Max differential pressure with thermostatic head installed: 0.25 bar. Body material: nickel‑plated CW617N brass. Gaskets and O‑rings materials: peroxide EPDM. Spring, washer and spindle material: stainless steel. Protective cap and manual head material: ABS.

IVAR

VS 2102 Thermostatic valve

Angle thermostatic valve with female connection. Connection to iron pipe x Connection to radiator: G 3/8"F x G 3/8"M with or without O-ring (with white protective cap or manual head), G 1/2"F x G 1/2"M with or without O-ring (with white protective cap or manual head), G 3/4"F x G 3/4"M with or without O-ring (with white protective cap or manual head), G 1"F x G 1"M with or without O-ring (with white protective cap), G 1"1/4F x G 1"1/4M with or without O-ring (with white protective cap). Flow rate pre-regulation only available for 3/8", 1/2" and 3/4" sizes: N-series (black protective cap or white manual head) or F-series (red protective cap or white manual head). Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol-water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Max differential pressure: 1 bar. Max differential pressure with thermostatic head installed: 0.25 bar. Body material: nickel-plated CW617N brass. Gaskets and O-rings materials: peroxide EPDM. Spring, washer and spindle material: stainless steel. Protective cap and manual head material: ABS.

EMCS compliant

.RFA

Control Unit for Heating and Cooling

IVAR

Download
Reflex Variomat VG

Variomat VG

Expansion pump dispenser primary vessel

Reflex

Variomat VG

Expansion pump dispenser primary vessel

EMCS compliant

.RFA

Expansion Vessel

Reflex

Download
Reflex Variomat VF

Variomat VF

Pump dispenser expansion auxiliary vessel

Reflex

Variomat VF

Pump dispenser expansion auxiliary vessel

EMCS compliant

.RFA

Expansion Vessel

Reflex

Download
Reflex Reflexomat RG

Reflexomat RG

Compressor expansion automat primary vessel

Reflex

Reflexomat RG

Compressor expansion automat primary vessel

EMCS compliant

.RFA

Expansion Vessel

Reflex

Download
Reflex Reflexomat RF

Reflexomat RF

Compressor expansion automat auxiliary vessel

Reflex

Reflexomat RF

Compressor expansion automat auxiliary vessel

EMCS compliant

.RFA

Expansion Vessel

Reflex

Download
Reflex Reflex S

Reflex S

Expansion vessel

Reflex

Reflex S

Expansion vessel

EMCS compliant

.RFA

Expansion Vessel

Reflex

Download
Reflex Reflex N

Reflex N

Expansion vessel

Reflex

Reflex N

Expansion vessel

EMCS compliant

.RFA

Expansion Vessel

Reflex

Download
Reflex Reflex V

Reflex V

Intermediate vessel

Reflex

Reflex V

Intermediate vessel

EMCS compliant

.RFA

Expansion Vessel

Reflex

Download
Reflex Reflex G

Reflex G

Expansion vessel

Reflex

Reflex G

Expansion vessel

EMCS compliant

.RFA

Expansion Vessel

Reflex

Download
Reflex Refix DT

Refix DT

Expansion vessel

Reflex

Refix DT

Expansion vessel

EMCS compliant

.RFA

Expansion Vessel

Reflex

Download
Reflex Refix DE

Refix DE

Expansion vessel

Reflex

Refix DE

Expansion vessel

EMCS compliant

.RFA

Expansion Vessel

Reflex

Download
Reflex Refix DC

Refix DC

Expansion vessel

Reflex

Refix DC

Expansion vessel

EMCS compliant

.RFA

Expansion Vessel

Reflex

Download
Reflex Reflex V

Reflex V

Intermediate vessel

Reflex

Reflex V

Intermediate vessel

EMCS compliant

.RFA

Expansion Vessel

Reflex

Download
Reflex Reflex S

Reflex S

Expansion vessel

Reflex

Reflex S

Expansion vessel

EMCS compliant

.RFA

Expansion Vessel

Reflex

Download
Reflex Reflex N

Reflex N

Expansion vessel

Reflex

Reflex N

Expansion vessel

EMCS compliant

.RFA

Expansion Vessel

Reflex

Download
Reflex Refix DE

Refix DE

Expansion vessel

Reflex

Refix DE

Expansion vessel

EMCS compliant

.RFA

Expansion Vessel

Reflex

Download
Reflex Refix DD

Refix DD

Expansion vessel

Reflex

Refix DD

Expansion vessel

EMCS compliant

.RFA

Expansion Vessel

Reflex

Download
Reflex Refix DC 25

Refix DC 25

Expansion vessel

Reflex

Refix DC 25

Expansion vessel

EMCS compliant

.RFA

Expansion Vessel

Reflex

Download
Reflex Servitec 95

Servitec 95

Self‑optimizing vacuum spray deaeration/make‑up unit

Reflex

Servitec 95

Self-optimizing vacuum spray deaeration/make-up unit

EMCS compliant

.RFA .IFC

Control Unit for Heating and Cooling

Reflex

Download
Reflex Servitec 75

Servitec 75

Self‑optimizing vacuum spray deaeration/make‑up unit

Reflex

Servitec 75

Self-optimizing vacuum spray deaeration/make-up unit

EMCS compliant

.RFA .IFC

Control Unit for Heating and Cooling

Reflex

Download
Reflex Servitec 60

Servitec 60

Self‑optimizing vacuum spray deaeration/make‑up unit

Reflex

Servitec 60

Self-optimizing vacuum spray deaeration/make-up unit

EMCS compliant

.RFA .IFC

Control Unit for Heating and Cooling

Reflex

Download
Reflex Servitec 35

Servitec 35

Self‑optimizing vacuum spray deaeration/make‑up unit

Reflex

Servitec 35

Self-optimizing vacuum spray deaeration/make-up unit

EMCS compliant

.RFA .IFC

Control Unit for Heating and Cooling

Reflex

Download
IVAR BRASS-ROD MANIFOLDS CI600N

BRASS-ROD MANIFOLDS CI600N

Flow manifold with flow meter/adjuster FLUXER (0‑5 l/min) and EUROK connections. Manifolds can be used as supply manifolds only. The body is made of brass CW617N. Nickel‑plated outer finished or yellow outer finished. Gaskets and O‑rings: Peroxide EPDM. Maximum fluid temperature: 90°C. Maximum operating pressure: 10 bar. Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 1 to 13 ways.

IVAR

BRASS-ROD MANIFOLDS CI600N

Flow manifold with flow meter/adjuster FLUXER (0-5 l/min) and EUROK connections. Manifolds can be used as supply manifolds only. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 90°C. Maximum operating pressure: 10 bar.  Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 1 to 13 ways.

EMCS compliant

.RFA

Distributor for Heating and Cooling

IVAR

Download
IVAR BRASS-ROD MANIFOLDS CS502N

BRASS-ROD MANIFOLDS CS502N

Plain manifold with EUROK connections. Manifolds can be used as supply or return manifolds. The body is made of brass CW617N. Nickel‑plated outer finished or yellow outer finished. Gaskets and O‑rings: Peroxide EPDM. Maximum fluid temperature: 120°C. Maximum operating pressure: 10 bar. Main connections: G 3/4"F or G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 2 to 13 ways.

IVAR

BRASS-ROD MANIFOLDS CS502N

Plain manifold with EUROK connections. Manifolds can be used as supply or return manifolds. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 120°C. Maximum operating pressure: 10 bar. Main connections: G 3/4"F or G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 2 to 13 ways.

EMCS compliant

.RFA

Distributor for Heating and Cooling

IVAR

Download
IVAR BRASS-ROD MANIFOLDS CI562MN

BRASS-ROD MANIFOLDS CI562MN

Kit made of flow manifold with double micrometric adjustment lockshields, return manifold with manually operated isolation valves, brackets and EUROK connections. The body is made of brass CW617N. Nickel‑plated outer finished or yellow outer finished. Gaskets and O‑rings: Peroxide EPDM. Maximum fluid temperature: 120°C. Maximum operating pressure: 10 bar. Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 2 to 13 ways.

IVAR

BRASS-ROD MANIFOLDS CI562MN

Kit made of flow manifold with double micrometric adjustment lockshields, return manifold with manually operated isolation valves, brackets and EUROK connections. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 120°C. Maximum operating pressure: 10 bar. Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 2 to 13 ways.

EMCS compliant

.RFA

Distributor for Heating and Cooling

IVAR

Download
IVAR BRASS-ROD MANIFOLDS CI552N

BRASS-ROD MANIFOLDS CI552N

Flow manifold with micrometric dually adjusted lockshields and EUROK connections. Manifolds can be used as supply manifolds only. The body is made of brass CW617N. Nickel‑plated outer finished or yellow outer finished. Gaskets and O‑rings: Peroxide EPDM. Maximum fluid temperature: 120°C.Maximum operating pressure: 10 bar. Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 1 to 13 ways.

IVAR

BRASS-ROD MANIFOLDS CI552N

Flow manifold with micrometric dually adjusted lockshields and EUROK connections. Manifolds can be used as supply manifolds only. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 120°C.Maximum operating pressure: 10 bar.  Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 1 to 13 ways.

EMCS compliant

.RFA

Distributor for Heating and Cooling

IVAR

Download
IVAR BRASS-ROD MANIFOLDS CI554MN

BRASS-ROD MANIFOLDS CI554MN

Return manifold with manually operated isolation valves and EUROK connections. Manifolds can be used as return manifolds only. The body is made of brass CW617N. Nickel‑plated outer finished or yellow outer finished. Gaskets and O‑rings: Peroxide EPDM. Maximum fluid temperature: 120°C. Maximum operating pressure: 10 bar. Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 1 to 13 ways.

IVAR

BRASS-ROD MANIFOLDS CI554MN

Return manifold with manually operated isolation valves and EUROK connections. Manifolds can be used as return manifolds only. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 120°C. Maximum operating pressure: 10 bar.  Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 1 to 13 ways.

EMCS compliant

.RFA

Distributor for Heating and Cooling

IVAR

Download
IVAR BRASS-ROD MANIFOLDS CI595MN

BRASS-ROD MANIFOLDS CI595MN

Kit made of flow manifold with flow meter/adjusters FLUXER (0‑5 l/min), return manifold with manually operated isolation valves, brackets and EUROK connections. The body is made of brass CW617N. Nickel‑plated outer finished or yellow outer finished. Gaskets and O‑rings: Peroxide EPDM. Maximum fluid temperature: 90°C. Maximum operating pressure: 10 bar. Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 2 to 13 ways.

IVAR

BRASS-ROD MANIFOLDS CI595MN

Kit made of flow manifold with flow meter/adjusters FLUXER (0-5 l/min), return manifold with manually operated isolation valves, brackets and EUROK connections. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 90°C. Maximum operating pressure: 10 bar. Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 2 to 13 ways.

EMCS compliant

.RFA

Distributor for Heating and Cooling

IVAR

Download
IVAR BRASS-ROD MANIFOLDS KC01KC

BRASS-ROD MANIFOLDS KC01KC

Kit made of flow manifold with double micrometric adjustment lockshields, return manifold with manually operated isolation valves, brackets, terminals, filling/drainage valves, air vent valves and EUROK connections. The body is made of brass CW617N. Nickel‑plated outer finished or yellow outer finished. Gaskets and O‑rings: Peroxide EPDM. Maximum fluid temperature: 120°C. Maximum operating pressure: 10 bar. Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 2 to 13 ways.

IVAR

BRASS-ROD MANIFOLDS KC01KC

Kit made of flow manifold with double micrometric adjustment lockshields, return manifold with manually operated isolation valves, brackets, terminals, filling/drainage valves, air vent valves and EUROK connections. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished.  Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 120°C. Maximum operating pressure: 10 bar. Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 2 to 13 ways.

EMCS compliant

.RFA

Distributor for Heating and Cooling

IVAR

Download
IVAR BRASS-ROD MANIFOLDS KC02KC

BRASS-ROD MANIFOLDS KC02KC

Kit made of flow manifold with flow meters/adjusters FLUXER (0‑5 l/min), return manifold with manually operated isolation valves, brackets, terminals, filling/drainage valves, air vent valves and EUROK connections. The body is made of brass CW617N. Nickel‑plated outer finished or yellow outer finished. Gaskets and O‑rings: Peroxide EPDM. Maximum fluid temperature: 120°C. Maximum operating pressure: 10 bar. Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 2 to 13 ways.

IVAR

BRASS-ROD MANIFOLDS KC02KC

Kit made of flow manifold with flow meters/adjusters FLUXER (0-5 l/min), return manifold with manually operated isolation valves, brackets, terminals, filling/drainage valves, air vent valves and EUROK connections. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished.  Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 120°C. Maximum operating pressure: 10 bar.  Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 2 to 13 ways.

EMCS compliant

.RFA

Distributor for Heating and Cooling

IVAR

Download
IVAR METERING MODULES_EQUIMETER

METERING MODULES_EQUIMETER

Equimeter metering module with unit for heat only. Heat metering unit: Qn =1, 5 m3/h (for modules with kv = 2, 25); Qn =2, 5 m3/h (for modules with kv = 2, 75). MATERIALS Heat metering monoblock: CB753S brass. Shut‑off valves: CW617N brass. Sealing elements: Peroxide EPDM. Cabinet: white painted galvanized steel sheet. Support: galvanized steel sheet. CONDITIONS OF USE Maximum static operating pressure: 10 bar. Maximum fluid temperature: 90 °C. CONNECTIONS G 3/4"M

IVAR

METERING MODULES_EQUIMETER

Equimeter metering module with unit for heat only. Heat metering unit: Qn =1,5 m3/h (for modules with kv = 2,25); Qn =2,5 m3/h (for modules with kv = 2,75).

MATERIALS
Heat metering monoblock: CB753S brass. Shut-off valves: CW617N brass. Sealing elements: Peroxide EPDM. Cabinet: white painted galvanized steel sheet. Support: galvanized steel sheet.

CONDITIONS OF USE
Maximum static operating pressure: 10 bar. Maximum fluid temperature: 90 °C.
CONNECTIONS
G 3/4"M

EMCS compliant

.RFA

Control Unit for Heating and Cooling

IVAR

Download
NIBE VVM-310

VVM-310

The NIBE VVM 310 is designed for combination with any NIBE air/water heat pump to create a highly‑efficient, flexible climate system for your home

NIBE

VVM-310

The NIBE VVM 310 is designed for combination with any NIBE air/water heat pump to create a highly-efficient, flexible climate system for your home

EMCS compliant

.DWG .RFA .IFC

Heat Pump

NIBE

Download
NIBE F1255

F1255

Inverter‑controlled ground source heat pump with an integrated hot water tank

NIBE

F1255

Inverter-controlled ground source heat pump with an integrated hot water tank

EMCS compliant

.DWG .RFA .IFC

Heat Pump

NIBE

Download
NIBE VVM-500

VVM-500

The NIBE VVM 500 is designed for combination with any NIBE air/water heat pump to create a highly‑efficient, flexible climate system for your home

NIBE

VVM-500

The NIBE VVM 500 is designed for combination with any NIBE air/water heat pump to create a highly-efficient, flexible climate system for your home

EMCS compliant

.DWG .RFA .IFC

Heat Pump

NIBE

Download
NIBE F1255PC

F1255PC

Inverter‑controlled ground source heat pump with integrated passive cooling and an integrated hot water tank

NIBE

F1255PC

Inverter-controlled ground source heat pump with integrated passive cooling and an integrated hot water tank

EMCS compliant

.DWG .RFA .IFC

Heat Pump

NIBE

Download
NIBE VVM-320

VVM-320

The NIBE VVM 320 is designed for combination with any NIBE air/water heat pump to create a highly‑efficient climate system for your home

NIBE

VVM-320

The NIBE VVM 320 is designed for combination with any NIBE air/water heat pump to create a highly-efficient climate system for your home

EMCS compliant

.DWG .RFA .IFC

Heat Pump

NIBE

Download