213 BIM collections found from 10 manufacturer(s) in Polen
IVAR CI400NB - Modular manifold EASY LOCK series

CI400NB - Modular manifold EASY LOCK series

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves). Modular plain manifold EASY-LOCK series. Manifolds can be used to supply DCW. The body is made of brass CW617N nickel-plated only externally. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 100°C. Maximum operating pressure: 10 bar. Main connections: G 3/4"F or G 1"F. Secondary connections: EUROK or 1/2"M or 1/2"M TP (flat seal). Sizes available: from 2 to 4 ways.

IVAR

CI400NB - Modular manifold EASY LOCK series

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves). Modular plain manifold EASY-LOCK series. Manifolds can be used to supply DCW. The body is made of brass CW617N nickel-plated only externally. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 100°C. Maximum operating pressure: 10 bar. Main connections: G 3/4"F or G 1"F. Secondary connections: EUROK or 1/2"M or 1/2"M TP (flat seal). Sizes available: from 2 to 4 ways.

EMCS-Kompatibilität

.RFA

Formteile für Sanitär und Kanalisation

IVAR

Herunterladen
IVAR CS200N - Modular plain manifold EASY LOCK series

CS200N - Modular plain manifold EASY LOCK series

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves). Modular plain manifold EASY-LOCK series. Manifolds can be used to supply DCW or DHW. The body is made of brass CW617N nickel-plated only externally. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 120°C. Maximum operating pressure: 10 bar. Main connections: G 3/4"F or G 1"F. Secondary connections: EUROK or 1/2"M or 1/2"M TP (flat seal). Sizes available: from 2 to 4 ways.

IVAR

CS200N - Modular plain manifold EASY LOCK series

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves). Modular plain manifold EASY-LOCK series. Manifolds can be used to supply DCW or DHW. The body is made of brass CW617N nickel-plated only externally. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 120°C. Maximum operating pressure: 10 bar. Main connections: G 3/4"F or G 1"F. Secondary connections: EUROK or 1/2"M or 1/2"M TP (flat seal). Sizes available: from 2 to 4 ways.

EMCS-Kompatibilität

.RFA

Formteile für Sanitär und Kanalisation

IVAR

Herunterladen
IVAR CI400NR - Modular manifold EASY LOCK series

CI400NR - Modular manifold EASY LOCK series

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves). Modular plain manifold EASY-LOCK series. Manifolds can be used to supply DHW. The body is made of brass CW617N nickel-plated only externally. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 100°C. Maximum operating pressure: 10 bar. Main connections: G 3/4"F or G 1"F. Secondary connections: EUROK or 1/2"M or 1/2"M TP (flat seal). Sizes available: from 2 to 4 ways.

IVAR

CI400NR - Modular manifold EASY LOCK series

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves). Modular plain manifold EASY-LOCK series. Manifolds can be used to supply DHW. The body is made of brass CW617N nickel-plated only externally. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 100°C. Maximum operating pressure: 10 bar. Main connections: G 3/4"F or G 1"F. Secondary connections: EUROK or 1/2"M or 1/2"M TP (flat seal). Sizes available: from 2 to 4 ways.

EMCS-Kompatibilität

.RFA

Formteile für Sanitär und Kanalisation

IVAR

Herunterladen
IVAR AC649 - Single bracket or EASY LOCK modular manifolds

AC649 - Single bracket or EASY LOCK modular manifolds

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves). Single bracket for EASY LOCK modular manifolds. Made of zinc plated steel. Two different sizes: DN 20 or DN 25.

IVAR

AC649 - Single bracket or EASY LOCK modular manifolds

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves).

Single bracket for EASY LOCK modular manifolds. Made of zinc plated steel. Two different sizes: DN 20 or DN 25.

EMCS-Kompatibilität

.RFA

Formteile für Sanitär und Kanalisation

IVAR

Herunterladen
IVAR AC628 - Double bracket for EASY LOCK modular manifolds

AC628 - Double bracket for EASY LOCK modular manifolds

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves). Double bracket for EASY LOCK modular manifolds. Made of zinc plated steel. Axle spacing: 200 mm. Two different sizes: DN 20 or DN 25.

IVAR

AC628 - Double bracket for EASY LOCK modular manifolds

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves).

Double bracket for EASY LOCK modular manifolds. Made of zinc plated steel. Axle spacing: 200 mm. Two different sizes: DN 20 or DN 25.

EMCS-Kompatibilität

.RFA

Formteile für Sanitär und Kanalisation

IVAR

Herunterladen
IVAR AC639 - Single bracket or EASY LOCK modular manifolds

AC639 - Single bracket or EASY LOCK modular manifolds

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves). Single bracket for EASY LOCK modular manifolds. Made of zinc plated steel. Two different sizes: DN 20 or DN 25.

IVAR

AC639 - Single bracket or EASY LOCK modular manifolds

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves).

Single bracket for EASY LOCK modular manifolds. Made of zinc plated steel. Two different sizes: DN 20 or DN 25.

EMCS-Kompatibilität

.RFA

Formteile für Sanitär und Kanalisation

IVAR

Herunterladen
IVAR AC659N - Orientable terminal for EASY LOCK modular manifolds

AC659N - Orientable terminal for EASY LOCK modular manifolds

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves). Orientable terminal for EASY LOCK modular manifolds complete with drainage valve and automatic air vent valve. Material: nichel plated brass. Size: M 1/2".

IVAR

AC659N - Orientable terminal for EASY LOCK modular manifolds

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves).

Orientable terminal for EASY LOCK modular manifolds complete with drainage valve and automatic air vent valve. Material: nichel plated brass. Size: M 1/2".

EMCS-Kompatibilität

.RFA

Formteile für Sanitär und Kanalisation

IVAR

Herunterladen
IVAR CI350N - Modular manifold EASY LOCK series

CI350N - Modular manifold EASY LOCK series

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves). Modular plain manifold EASY LOCK series. Manifolds can be used to supply DCW or DHW. The body is made of brass CW617N nickel-plated only externally. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 100°C. Maximum operating pressure: 10 bar. Main connections: G 3/4"F or G 1"F. Secondary connections: EUROK or 1/2"M or 1/2"M TP (flat seal). Sizes available: from 2 to 5 ways.

IVAR

CI350N - Modular manifold EASY LOCK series

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves). Modular plain manifold EASY LOCK series. Manifolds can be used to supply DCW or DHW. The body is made of brass CW617N nickel-plated only externally. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 100°C. Maximum operating pressure: 10 bar. Main connections: G 3/4"F or G 1"F. Secondary connections: EUROK or 1/2"M or 1/2"M TP (flat seal). Sizes available: from 2 to 5 ways.

EMCS-Kompatibilität

.RFA

Formteile für Sanitär und Kanalisation

IVAR

Herunterladen
IVAR AC850 - Plastic box with bottom and fastening kit for coplanar and modular manifolds

AC850 - Plastic box with bottom and fastening kit for coplanar and modular manifolds

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves). Plastic box with bottom and fastening kit for coplanar and modular manifolds. Two different sizes: DN 20 or DN 25.

IVAR

AC850 - Plastic box with bottom and fastening kit for coplanar and modular manifolds

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves).
Plastic box with bottom and fastening kit for coplanar and modular manifolds. Two different sizes: DN 20 or DN 25.

EMCS-Kompatibilität

.RFA

Formteile für Sanitär und Kanalisation

IVAR

Herunterladen
IVAR IVAR ESAT DUAL

IVAR ESAT DUAL

IVAR E-SAT DUAL is a double heat exchanger satellite module which allows on-site production of DHW and hot water for the heating system, with only AFS connections and technical water supply/return. Thanks to the integrated electronics IVAR E-SAT modulates the technical water flow to guarantee a low return temperature to the boiler. The double exchanger solution, completely separating the centralized system from the domestic one, guarantees easy maintenance of the single user system. IVAR ESAT DUAL can be equipped with differential pressure valves and shut-off valves kit.

IVAR

IVAR ESAT DUAL

IVAR E-SAT DUAL is a double heat exchanger satellite module which allows on-site production of DHW and hot water for the heating system, with only AFS connections and technical water supply/return. Thanks to the integrated electronics IVAR E-SAT modulates the technical water flow to guarantee a low return temperature to the boiler. The double exchanger solution, completely separating the centralized system from the domestic one, guarantees easy maintenance of the single user system.
IVAR ESAT DUAL can be equipped with differential pressure valves and shut-off valves kit.

EMCS-Kompatibilität

.RFA .PDF

Verteiler für Zentralheizung

IVAR

Herunterladen
IVAR AC852 - Plastic box with bottom for modular manifolds

AC852 - Plastic box with bottom for modular manifolds

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves). Plastic box with bottom for modular manifolds (without fastening kit, to order separately). H: from 350 to 400 mm. W: from 350 to 800 mm. D: from 90 to 95 mm. With/without protection for plastering operations.

IVAR

AC852 - Plastic box with bottom for modular manifolds

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves).

Plastic box with bottom for modular manifolds (without fastening kit, to order separately). H: from 350 to 400 mm. W: from 350 to 800 mm. D: from 90 to 95 mm. With/without protection for plastering operations.

EMCS-Kompatibilität

.RFA

Formteile für Sanitär und Kanalisation

IVAR

Herunterladen
IVAR Modular manifolds EASY-RADIANT

Modular manifolds EASY-RADIANT

Modular return manifold EASY RADIANT series (centre-to-centre distance 40 mm) with isolation valves with protection cap for

IVAR

Modular manifolds EASY-RADIANT

Modular return manifold EASY RADIANT series (centre-to-centre distance 40 mm) with isolation valves with protection cap for

EMCS-Kompatibilität

.RVT .RFA

Manifold

IVAR

Herunterladen
IVAR VARIMIX

VARIMIX

Distribution and mixing system IVAR VARIMIX for thermal power stations, modular with: hydraulic separator, modular distribution manifold, high-temperature direct flow kit, low-temperature mixing kit, motor for mixing valves, expansion tank, motor for zone ball zone valves. VARIMIX allows to arrange the mechanical room according to a new concept of space and functionality. This solution gives the opportunity to manage multiple thermal areas with different characteristics as truly independent zones in a neat, rational space, thanks to its modular structure and outstanding installation flexibility. In low temperature kits, the mixer valve is available with different hydraulic features and in 3-way or 4-way versions. By producing a mixture even on the return line, it is particularly suitable for older boilers where the return temperature must not be too low to avoid corrosion. Finally, the “LT” modules are specifically designed for applications with low temperature heat sources (for example, heat pumps). Main features: easy to install; compact and neat; fully reversible; versatile and flexible; suitable for heating and cooling applications. Max primary flow rate: 4500 l/h. Max flow rate for each kit: 3000 l/h.

IVAR

VARIMIX

Distribution and mixing system IVAR VARIMIX for thermal power stations, modular with: hydraulic separator, modular distribution manifold, high-temperature direct flow kit, low-temperature mixing kit, motor for mixing valves, expansion tank, motor for zone ball zone valves. VARIMIX allows to arrange the mechanical room according to a new concept of space and functionality. This solution gives the opportunity to manage multiple thermal areas with different characteristics as truly independent zones in a neat, rational space, thanks to its modular structure and outstanding installation flexibility. In low temperature kits, the mixer valve is available with different hydraulic features and in 3-way or 4-way versions. By producing a mixture even on the return line, it is particularly suitable for older boilers where the return temperature must not be too low to avoid corrosion. Finally, the “LT” modules are specifically designed for applications with low temperature heat sources (for example, heat pumps). Main features: easy to install; compact and neat; fully reversible; versatile and flexible; suitable for heating and cooling applications. Max primary flow rate: 4500 l/h. Max flow rate for each kit: 3000 l/h.

EMCS-Kompatibilität

.RVT .RFA

Verteiler für Zentralheizung

IVAR

Herunterladen
IVAR MULTIMIX

MULTIMIX

Distribution and mixing system IVAR MULTIMIX for thermal power stations, modular with: - Manifold made of CB753S brass from casting with adjustable and interceptable hydraulic separator integrated. Complete with union with swivel fittings G 1” for the connection to distribution kits, shut-off ball valves DN 25 at the inlets, thermomanometer 0-6 bar/0-120 ◦C and automatic air vent valve. 2-way or 3-way versions available. Possibility of connection to the primary circuit from above, below, right or left. Expandable by connecting to other manifolds with swivel nipples G 1”. Other components made of CW617N brass. Gaskets and o-rings made of Peroxide-cured EPDM. Connections to the primary circuit G 1”F, centre distance delivery/return 52 mm (inlet from the side), 197 mm (inlet from above or below, 2-way manifold), 170 mm (inlet from above or below, 3-way manifold); connections to the distribution circuits with swivel nut G 1”F, centre distance delivery/return 45 mm. Max operating temperature 120 ◦C. Max operating pressure 10 bar. Max primary circuit flow rate 3500 l/h. - High-temperature direct flow kit complete with telescopic system for pump connection, shut-off ball valves for pump connection, delivery and return thermometers 0÷80 ◦C; check valve. Primary circuit connections G 1” M, delivery/return centre distance 45 mm; distribution circuits connections G 3/4”F, delivery/return centre distance 90 mm. Parts from casting: CB753S brass. Other parts made of CW617N brass. Gaskets and o-rings: peroxide-cured EPDM. Max operating temperature (pump excluded) 120 ◦C. Max operating pressure 10 bar. - Low temperature mixing kit complete with 3-way mixing valve with headwork for thermostatic or motorisable control, secondary bypass with micrometric dually adjusted lockshields and position memory, telescopic system for pump connection, shut-off ball valves for pump connection, delivery and return thermometers 0÷80 ◦C, check valve, fixed setting safety thermostat 60◦C. Primary circuit connections (manifold-separator) G 1”M, centre distance delivery/return 45 mm; heating circuits connections G 3/4”F, centre distance delivery/return 90 mm. Parts from casting: CB753S brass. Other parts: CW617N brass. Gaskets and o-rings: peroxide-cured EPDM. Max operating temperature (pump excluded) 120 ◦C. Max operating pressure 10 bar. - Variable-speed electronic pump WILO4F centre distance 130 mm. - 3-speed standard pump WILO3F centre distance 130 mm. - Polypropylene insulation shell. - Wall fitted cabinet with variable height and depth. - T 5011 U: thermostatic head with incorporated control and immersion remote sensor. Connection: M30 x 1.5. Probe holder connection: 1/2". Range: 30-55 °C. Cable lenght: 2 m. - RV 01: axial motor. Connection: M30 x 1.5. 3-point adjustment 230 V AC or 24 V AC or proportional 0-10 V 24 V AC.

IVAR

MULTIMIX

Distribution and mixing system IVAR MULTIMIX for thermal power stations, modular with: - Manifold made of CB753S brass from casting with adjustable and interceptable hydraulic separator integrated. Complete with union with swivel fittings G 1” for the connection to distribution kits, shut-off ball valves DN 25 at the inlets, thermomanometer 0-6 bar/0-120 ◦C and automatic air vent valve. 2-way or 3-way versions available. Possibility of connection to the primary circuit from above, below, right or left. Expandable by connecting to other manifolds with swivel nipples G 1”. Other components made of CW617N brass. Gaskets and o-rings made of Peroxide-cured EPDM. Connections to the primary circuit G 1”F, centre distance delivery/return 52 mm (inlet from the side), 197 mm (inlet from above or below, 2-way manifold), 170 mm (inlet from above or below, 3-way manifold); connections to the distribution circuits with swivel nut G 1”F, centre distance delivery/return 45 mm. Max operating temperature 120 ◦C. Max operating pressure 10 bar. Max primary circuit flow rate 3500 l/h. - High-temperature direct flow kit complete with telescopic system for pump connection, shut-off ball valves for pump connection, delivery and return thermometers 0÷80 ◦C; check valve. Primary circuit connections G 1” M, delivery/return centre distance 45 mm; distribution circuits connections G 3/4”F, delivery/return centre distance 90 mm. Parts from casting: CB753S brass. Other parts made of CW617N brass. Gaskets and o-rings: peroxide-cured EPDM. Max operating temperature (pump excluded) 120 ◦C. Max operating pressure 10 bar. - Low temperature mixing kit complete with 3-way mixing valve with headwork for thermostatic or motorisable control, secondary bypass with micrometric dually adjusted lockshields and position memory, telescopic system for pump connection, shut-off ball valves for pump connection, delivery and return thermometers 0÷80 ◦C, check valve, fixed setting safety thermostat 60◦C. Primary circuit connections (manifold-separator) G 1”M, centre distance delivery/return 45 mm; heating circuits connections G 3/4”F, centre distance delivery/return 90 mm. Parts from casting: CB753S brass. Other parts: CW617N brass. Gaskets and o-rings: peroxide-cured EPDM. Max operating temperature (pump excluded) 120 ◦C. Max operating pressure 10 bar. - Variable-speed electronic pump WILO4F centre distance 130 mm. - 3-speed standard pump WILO3F centre distance 130 mm. - Polypropylene insulation shell. - Wall fitted cabinet with variable height and depth. - T 5011 U: thermostatic head with incorporated control and immersion remote sensor. Connection: M30 x 1.5. Probe holder connection: 1/2". Range: 30-55 °C. Cable lenght: 2 m. - RV 01: axial motor. Connection: M30 x 1.5. 3-point adjustment 230 V AC or 24 V AC or proportional 0-10 V 24 V AC.

EMCS-Kompatibilität

.RVT .RFA

Verteiler für Zentralheizung

IVAR

Herunterladen
IVAR RTV Thermostatic Valve For Recirculation Branch Balancing

RTV Thermostatic Valve For Recirculation Branch Balancing

IVAR RTV: thermostatic valve for controlling the water temperature in the recirculation branches. Balancing thermostatic insert with fixed point adjustment settable with graduated knob equipped with locking mechanism. Version A with only recirculation branch balancing. Version B with thermostatic control for thermal disinfection cycle. Version C with electronic thermal disinfection cycle. Connections: 1/2" F or 3/4" F. Adjustment range 35-60 °C. ΔP maximum at the ends of the valve 1 bar. Main material: brass CW617N. Adjustment knob: ABS. O-ring seal: peroxide EPDM.

IVAR

RTV Thermostatic Valve For Recirculation Branch Balancing

IVAR RTV: thermostatic valve for controlling the water temperature in the recirculation branches. Balancing thermostatic insert with fixed point adjustment settable with graduated knob equipped with locking mechanism. Version A with only recirculation branch balancing. Version B with thermostatic control for thermal disinfection cycle. Version C with electronic thermal disinfection cycle. Connections: 1/2" F or 3/4" F. Adjustment range 35-60 °C. ΔP maximum at the ends of the valve 1 bar. Main material: brass CW617N. Adjustment knob: ABS. O-ring seal: peroxide EPDM.

EMCS-Kompatibilität

.RVT .RFA

Ventil für Heizung und Kühlung

IVAR

Herunterladen
IVAR Dirtstop® XL

Dirtstop® XL

IVAR Dirtstop® XL: triple effect magnetic dirt separator: cyclonic action guaranteed by a patented internal insert, developed to guide the fluid directed to the boiler in order to maximize the slowing down and decantation of the debris; subsequent removal of ferrous particles by means of a neodymium magnet, magnetic field 14000 G; mechanical filtration with an 800 μm mesh filter (pre- assembled 500 μm filter for the first cleaning of the system). Internal components completely inspectable, removable and washable by removing the upper plug, with the special lever provided. Manual air vent valve. Draining valve with opening lever and tap. Swivel fitting for mounting to the pipeline in different orientations, with the special lever provided. Allowed installation on horizontal, vertical or oblique lines. Buttonhole on magnetic insert, sealing band supplied. Materials: body, cyclonic insert and cap in PA66 + GF 30%; "T" joint and locking ring nut in PA66 + GF 30%; filters in stainless steel AISI 304; seals in peroxide EPDM. Compatible fluids: water; water + glycol max 50%. Maximum recommended flow rate: 2.13 m3/h. Maximum operating pressure: 3 bar. Operating temperature: 0-90 °C. Flow coefficient Kv: 6.7 m3 /h. Connections: Ø22 x Ø22 copper pipe (520124); 3/4" F x 3/4" F (520135); 1"F x 1" F (520136); 1"1/4 F x 1"1/4 F (520139).

IVAR

Dirtstop® XL

IVAR Dirtstop® XL: triple effect magnetic dirt separator: cyclonic action guaranteed by a patented internal insert, developed to guide the fluid directed to the boiler in order to maximize the slowing down and decantation of the debris; subsequent removal of ferrous particles by means of a neodymium magnet, magnetic field 14000 G; mechanical filtration with an 800 μm mesh filter (pre- assembled 500 μm filter for the first cleaning of the system). Internal components completely inspectable, removable and washable by removing the upper plug, with the special lever provided. Manual air vent valve. Draining valve with opening lever and tap. Swivel fitting for mounting to the pipeline in different orientations, with the special lever provided. Allowed installation on horizontal, vertical or oblique lines. Buttonhole on magnetic insert, sealing band supplied. Materials: body, cyclonic insert and cap in PA66 + GF 30%; "T" joint and locking ring nut in PA66 + GF 30%; filters in stainless steel AISI 304; seals in peroxide EPDM. Compatible fluids: water; water + glycol max 50%. Maximum recommended flow rate: 2.13 m3/h. Maximum operating pressure: 3 bar. Operating temperature: 0-90 °C. Flow coefficient Kv: 6.7 m3 /h. Connections: Ø22 x Ø22 copper pipe (520124); 3/4" F x 3/4" F (520135); 1"F x 1" F (520136); 1"1/4 F x 1"1/4 F (520139).

EMCS-Kompatibilität

.RVT .RFA

Steuereinheit für Zentralheizung

IVAR

Herunterladen
IVAR COMBIMIX

COMBIMIX

Mixing and boosting unit IVAR COMBIMIX for radiant installations complete with two-way mixing valve, balancing valve (on the cold way), two shut-off ball valves for the pump, two fill/drain valves, two automatic air vent valves, three thermometers 0÷80 °C (on delivery and return of boiler circuit and on delivery of mixed circuit), temperature sensor pocket (on delivery of mixed circuit), shut-off valve (on return of boiler circuit), boiler circuit connections G 1”F (centre distance 200 mm) and mixed circuit connections G 1”M with swivelling nipples (centre distance 200 mm). Upper and lower parts made of nickel-plated CB753S brass; pipe made of nickel-plated half-hard copper; gaskets and O-rings made of peroxide-cured EPDM; other parts made of CW617N brass. Max operating temperature 100 °C. Max operating pressure 10 bar. Fixed point mixing 20÷60 °C by thermostatic control head with remote sensor T5011 included (max differential pressure at mixing valve ends 250 mbar) or set up for outside compensated temperature mixing by integrating axial servomotor IVAR RV 01 or thermoelectric actuator IVAR TE 3061. Differential bypass valve (optional) 0.2÷0.6 bar with half-hard nickel-plated pipe. Pump space 130 mm or 180 mm, G 1”1/2F flat seal connections. Equipped with variable-speed electronic pump WILO4F or variable-speed electronic pump WILO4F-180 or without pump. Accessories: high-temperature kit with pair of manifolds 1” x EUROK with shut-off and lockshield valves CEP/02 I – CEP/03 I (2 ways) – (3 ways), high-temperature kit with pair of simple manifolds 1” x EUROK CEP/02 – CEP/03 (2 ways) – (3 ways), insulation shell ACM 01, threaded spacer for pumps AC 633.

IVAR

COMBIMIX

Mixing and boosting unit IVAR COMBIMIX for radiant installations complete with two-way mixing valve, balancing valve (on the cold way), two shut-off ball valves for the pump, two fill/drain valves, two automatic air vent valves, three thermometers 0÷80 °C (on delivery and return of boiler circuit and on delivery of mixed circuit), temperature sensor pocket (on delivery of mixed circuit), shut-off valve (on return of boiler circuit), boiler circuit connections G 1”F (centre distance 200 mm) and mixed circuit connections G 1”M with swivelling nipples (centre distance 200 mm). Upper and lower parts made of nickel-plated CB753S brass; pipe made of nickel-plated half-hard copper; gaskets and O-rings made of peroxide-cured EPDM; other parts made of CW617N brass. Max operating temperature 100 °C. Max operating pressure 10 bar. Fixed point mixing 20÷60 °C by thermostatic control head with remote sensor T5011 included (max differential pressure at mixing valve ends 250 mbar) or set up for outside compensated temperature mixing by integrating axial servomotor IVAR RV 01 or thermoelectric actuator IVAR TE 3061. Differential bypass valve (optional) 0.2÷0.6 bar with half-hard nickel-plated pipe. Pump space 130 mm or 180 mm, G 1”1/2F flat seal connections. Equipped with variable-speed electronic pump WILO4F or variable-speed electronic pump WILO4F-180 or without pump. Accessories: high-temperature kit with pair of manifolds 1” x EUROK with shut-off and lockshield valves CEP/02 I – CEP/03 I (2 ways) – (3 ways), high-temperature kit with pair of simple manifolds 1” x EUROK CEP/02 – CEP/03 (2 ways) – (3 ways), insulation shell ACM 01, threaded spacer for pumps AC 633.

EMCS-Kompatibilität

.RVT .RFA

Verteiler für Zentralheizung

IVAR

Herunterladen
IVAR IVARSAT-H VNR

IVARSAT-H VNR

Satellite module that independently manages high-temperature heating (direct circuit) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; domestic water preheating device; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; summer/winter two-way valve; pocket for temperature immersion probe on delivery side of primary circuit; balancing lockshield of primary circuit with double micrometrical adjustment; balancing lockshield of heating/domestic water circuit; differential overpressure by-pass valve on primary circuit; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. Model “1” with high-temperature domestic water outlet. Model “R” with hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor. In compliance with Belgaqua.

IVAR

IVARSAT-H VNR

Satellite module that independently manages high-temperature heating (direct circuit) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; domestic water preheating device; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; summer/winter two-way valve; pocket for temperature immersion probe on delivery side of primary circuit; balancing lockshield of primary circuit with double micrometrical adjustment; balancing lockshield of heating/domestic water circuit; differential overpressure by-pass valve on primary circuit; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. Model “1” with high-temperature domestic water outlet. Model “R” with hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor. In compliance with Belgaqua.

EMCS-Kompatibilität

.RFA

Verteiler für Zentralheizung

IVAR

Herunterladen
IVAR IVARSAT-H

IVARSAT-H

Satellite module that independently manages high-temperature heating (direct circuit) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; domestic water preheating device; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; summer/winter two-way valve; pocket for temperature immersion probe on delivery side of primary circuit; balancing lockshield of primary circuit with double micrometrical adjustment; balancing lockshield of heating/domestic water circuit; differential overpressure by-pass valve on primary circuit; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. Model “1” with high-temperature domestic water outlet. Model “R” with hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor.

IVAR

IVARSAT-H

Satellite module that independently manages high-temperature heating (direct circuit) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; domestic water preheating device; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; summer/winter two-way valve; pocket for temperature immersion probe on delivery side of primary circuit; balancing lockshield of primary circuit with double micrometrical adjustment; balancing lockshield of heating/domestic water circuit; differential overpressure by-pass valve on primary circuit; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. Model “1” with high-temperature domestic water outlet. Model “R” with hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor.

EMCS-Kompatibilität

.RFA

Verteiler für Zentralheizung

IVAR

Herunterladen
IVAR IVARSAT-L-LE

IVARSAT-L-LE

Satellite module that independently manages low-temperature heating (mixed circuit) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; mixing valve for fixed point mixing (with thermostatic control head and remote contact probe) or outside compensated temperature mixing (with axial servomotor and control unit); three-speed pump / model “E” with variable-speed pump EEI<20; summer/winter two-way valve; pocket for temperature immersion probe on delivery side of primary circuit; balancing valve on primary circuit; balancing by-pass valve on mixed circuit; balancing lockshield of heating/domestic water circuit; hydraulic separator with built-in check valve; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. Model “1” with high-temperature domestic water outlet. Model “R” with hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor.

IVAR

IVARSAT-L-LE

Satellite module that independently manages low-temperature heating (mixed circuit) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; mixing valve for fixed point mixing (with thermostatic control head and remote contact probe) or outside compensated temperature mixing (with axial servomotor and control unit); three-speed pump / model “E” with variable-speed pump EEI<20; summer/winter two-way valve; pocket for temperature immersion probe on delivery side of primary circuit; balancing valve on primary circuit; balancing by-pass valve on mixed circuit; balancing lockshield of heating/domestic water circuit; hydraulic separator with built-in check valve; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. Model “1” with high-temperature domestic water outlet. Model “R” with hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor.

EMCS-Kompatibilität

.RFA

Verteiler für Zentralheizung

IVAR

Herunterladen
IVAR BRASS-ROD MANIFOLDS_CI562MN

BRASS-ROD MANIFOLDS_CI562MN

Kit made of flow manifold with double micrometric adjustment lockshields, return manifold with manually operated isolation valves, brackets and EUROK connections. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 120°C. Maximum operating pressure: 10 bar. Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 2 to 13 ways.

IVAR

BRASS-ROD MANIFOLDS_CI562MN

Kit made of flow manifold with double micrometric adjustment lockshields, return manifold with manually operated isolation valves, brackets and EUROK connections. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 120°C. Maximum operating pressure: 10 bar. Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 2 to 13 ways.

EMCS-Kompatibilität

.RFA

Verteiler für Zentralheizung

IVAR

Herunterladen
IVAR BRASS-ROD MANIFOLDS CI552N

BRASS-ROD MANIFOLDS CI552N

Flow manifold with micrometric dually adjusted lockshields and EUROK connections. Manifolds can be used as supply manifolds only. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 120°C.Maximum operating pressure: 10 bar.  Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 1 to 13 ways.

IVAR

BRASS-ROD MANIFOLDS CI552N

Flow manifold with micrometric dually adjusted lockshields and EUROK connections. Manifolds can be used as supply manifolds only. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 120°C.Maximum operating pressure: 10 bar.  Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 1 to 13 ways.

EMCS-Kompatibilität

.RFA

Verteiler für Zentralheizung

IVAR

Herunterladen
IVAR IVARSAT-HL-HLE

IVARSAT-HL-HLE

Satellite module that independently manages high-temperature and low-temperature heating (direct and mixed circuits) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; mixing valve for fixed point mixing (with thermostatic control head and remote contact probe) or outside compensated temperature mixing (with axial servomotor and control unit); three-speed pump / model “E” with variable-speed pump EEI<20; summer/winter two-way valve on high-temperature and low-temperature circuits; pocket for temperature immersion probe on delivery side of primary circuit; balancing valve on primary circuit; balancing by-pass valve on mixed circuit; balancing lockshield of heating/domestic water circuit; hydraulic separator with built-in check valve; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. High-temperature domestic water outlet. Hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor.

IVAR

IVARSAT-HL-HLE

Satellite module that independently manages high-temperature and low-temperature heating (direct and mixed circuits) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; mixing valve for fixed point mixing (with thermostatic control head and remote contact probe) or outside compensated temperature mixing (with axial servomotor and control unit); three-speed pump / model “E” with variable-speed pump EEI<20; summer/winter two-way valve on high-temperature and low-temperature circuits; pocket for temperature immersion probe on delivery side of primary circuit; balancing valve on primary circuit; balancing by-pass valve on mixed circuit; balancing lockshield of heating/domestic water circuit; hydraulic separator with built-in check valve; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. High-temperature domestic water outlet. Hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor.

EMCS-Kompatibilität

.RFA

Verteiler für Zentralheizung

IVAR

Herunterladen
IVAR UNIMIX / UNIMIX-C

UNIMIX / UNIMIX-C

Mixing and pump units for radiant systems UNIMIX/UNIMIC-C modular with: UM 01 – UM 01D/S: regulation unit UNIMIX with/without pump complete with 3-way mixing valve with headwork for thermostatic control, secondary by-pass with double micrometric adjustment and position memory, primary by-pass for recirculation, thermomanometer 0÷120 °C 0÷6 bar for mixed water, thermometers 0÷80 °C for delivery and return waters, probe pocket for mixed water, shut-off ball valves G 1” secondary side and automatic air vent valve. Available with or without straight or angled shut-off ball valves G 3/4”F on primary side. Available with or without 3-speed standard pump WILO3F centre distance 130 mm or variable-speed electronic pump WILO4F centre distance 130 mm. Body made of nickel-plated CB753S brass; gaskets and O-rings made of peroxide-cured EPDM; other parts made of CW617N brass. Max operating temperature 100 °C. Max operating pressure 10 bar. Max differential pressure at mixing valve ends 250 mbar. UMC 01 – UMC 01D/S: regulation unit UNIMIX-C with/without pump complete with 3-way mixing valve with headwork for thermostatic control, secondary by-pass with double micrometric adjustment and position memory, primary by-pass for recirculation, thermometer 0÷80 °C for mixed water and probe pocket for mixed water. Available with or without straight or angled shut-off ball valves G 3/4”F on primary side. Available with or without 3-speed standard pump WILO3F centre distance 130 mm or variable-speed electronic pump WILO4F centre distance 130 mm. Body made of nickel-plated CB753S brass; gaskets and O-rings made of peroxide-cured EPDM; other parts made of CW617N brass. Max operating temperature 100 °C. Max operating pressure 10 bar. Max differential pressure at mixing valve ends 250 mbar. AUM 03: expanded polypropylene insulating cover. T 5011 U: thermostatic head with incorporated control and immersion remote sensor. Range 30÷55 °C o 25÷50 °C. Cable lengh 2 m. RV 01: axial servomotor M30x1.5. 3-point adjustment 230 V AC or proportional 0-10 V 24 V AC with display. AUM 01 - AUM 11 D/S: high-temperature kit for UNIMIX/UNIMIX-C with primary side connections G 1” and plain manifolds with 3 outlets (EUROK outlets). Complete with fill/drain valve and differential pressure by-pass valve 0.2÷0.6 bar. Available with or without straight or angled shut-off ball valves G 1” primary side. AUM 02 - AUM 12 D/S: high-temperature kit for UNIMIX/UNIMIX-C with primary side connections G 1” and manifolds with 3 outlets (delivery: double micrometric adjustment lockshield; return: headwork for thermostatic control with protection cap; EUROK outlets). Complete with fill/drain valve and differential pressure by-pass valve 0.2÷0.6 bar. Available with or without straight or angled shut-off ball valves G 1”F on primary side. AC 613 FU: fixed setting 60 °C safety thermostat pre-wired.

IVAR

UNIMIX / UNIMIX-C

Mixing and pump units for radiant systems UNIMIX/UNIMIC-C modular with: UM 01 – UM 01D/S: regulation unit UNIMIX with/without pump complete with 3-way mixing valve with headwork for thermostatic control, secondary by-pass with double micrometric adjustment and position memory, primary by-pass for recirculation, thermomanometer 0÷120 °C 0÷6 bar for mixed water, thermometers 0÷80 °C for delivery and return waters, probe pocket for mixed water, shut-off ball valves G 1” secondary side and automatic air vent valve. Available with or without straight or angled shut-off ball valves G 3/4”F on primary side. Available with or without 3-speed standard pump WILO3F centre distance 130 mm or variable-speed electronic pump WILO4F centre distance 130 mm. Body made of nickel-plated CB753S brass; gaskets and O-rings made of peroxide-cured EPDM; other parts made of CW617N brass. Max operating temperature 100 °C. Max operating pressure 10 bar. Max differential pressure at mixing valve ends 250 mbar. UMC 01 – UMC 01D/S: regulation unit UNIMIX-C with/without pump complete with 3-way mixing valve with headwork for thermostatic control, secondary by-pass with double micrometric adjustment and position memory, primary by-pass for recirculation, thermometer 0÷80 °C for mixed water and probe pocket for mixed water. Available with or without straight or angled shut-off ball valves G 3/4”F on primary side. Available with or without 3-speed standard pump WILO3F centre distance 130 mm or variable-speed electronic pump WILO4F centre distance 130 mm. Body made of nickel-plated CB753S brass; gaskets and O-rings made of peroxide-cured EPDM; other parts made of CW617N brass. Max operating temperature 100 °C. Max operating pressure 10 bar. Max differential pressure at mixing valve ends 250 mbar. AUM 03: expanded polypropylene insulating cover. T 5011 U: thermostatic head with incorporated control and immersion remote sensor. Range 30÷55 °C o 25÷50 °C. Cable lengh 2 m. RV 01: axial servomotor M30x1.5. 3-point adjustment 230 V AC or proportional 0-10 V 24 V AC with display. AUM 01 - AUM 11 D/S: high-temperature kit for UNIMIX/UNIMIX-C with primary side connections G 1” and plain manifolds with 3 outlets (EUROK outlets). Complete with fill/drain valve and differential pressure by-pass valve 0.2÷0.6 bar. Available with or without straight or angled shut-off ball valves G 1” primary side. AUM 02 - AUM 12 D/S: high-temperature kit for UNIMIX/UNIMIX-C with primary side connections G 1” and manifolds with 3 outlets (delivery: double micrometric adjustment lockshield; return: headwork for thermostatic control with protection cap; EUROK outlets). Complete with fill/drain valve and differential pressure by-pass valve 0.2÷0.6 bar. Available with or without straight or angled shut-off ball valves G 1”F on primary side. AC 613 FU: fixed setting 60 °C safety thermostat pre-wired.

EMCS-Kompatibilität

.RVT .RFA

Steuereinheit für Zentralheizung

IVAR

Herunterladen