641 BIM collections found from 50 manufacturer(s) in Spanien
IVAR CI400NB - Modular manifold EASY LOCK series

CI400NB - Modular manifold EASY LOCK series

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves). Modular plain manifold EASY-LOCK series. Manifolds can be used to supply DCW. The body is made of brass CW617N nickel-plated only externally. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 100°C. Maximum operating pressure: 10 bar. Main connections: G 3/4"F or G 1"F. Secondary connections: EUROK or 1/2"M or 1/2"M TP (flat seal). Sizes available: from 2 to 4 ways.

IVAR

CI400NB - Modular manifold EASY LOCK series

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves). Modular plain manifold EASY-LOCK series. Manifolds can be used to supply DCW. The body is made of brass CW617N nickel-plated only externally. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 100°C. Maximum operating pressure: 10 bar. Main connections: G 3/4"F or G 1"F. Secondary connections: EUROK or 1/2"M or 1/2"M TP (flat seal). Sizes available: from 2 to 4 ways.

EMCS-Kompatibilität

.RFA

Formteile für Sanitär und Kanalisation

IVAR

Herunterladen
IVAR CS200N - Modular plain manifold EASY LOCK series

CS200N - Modular plain manifold EASY LOCK series

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves). Modular plain manifold EASY-LOCK series. Manifolds can be used to supply DCW or DHW. The body is made of brass CW617N nickel-plated only externally. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 120°C. Maximum operating pressure: 10 bar. Main connections: G 3/4"F or G 1"F. Secondary connections: EUROK or 1/2"M or 1/2"M TP (flat seal). Sizes available: from 2 to 4 ways.

IVAR

CS200N - Modular plain manifold EASY LOCK series

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves). Modular plain manifold EASY-LOCK series. Manifolds can be used to supply DCW or DHW. The body is made of brass CW617N nickel-plated only externally. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 120°C. Maximum operating pressure: 10 bar. Main connections: G 3/4"F or G 1"F. Secondary connections: EUROK or 1/2"M or 1/2"M TP (flat seal). Sizes available: from 2 to 4 ways.

EMCS-Kompatibilität

.RFA

Formteile für Sanitär und Kanalisation

IVAR

Herunterladen
DINUY S.A. DM TEC B1N

DM TEC B1N

360º Bluetooth detector ceiling-mounted black

DINUY S.A.

DM TEC B1N

360º Bluetooth detector ceiling-mounted black

EMCS-Kompatibilität

.DWG .RFA .IFC

Detektor

DINUY S.A.

Herunterladen
Mark Climate Technology Infra Aqua Eco Deckenstrahlplatte TYPE 1

Infra Aqua Eco Deckenstrahlplatte TYPE 1

Die INFRA AQUA ECO ist eine wassergespeiste Deckenstrahlplatte die standardmäßig mit einer Mineralwollisolierung versehen ist. Die Isolierung verhindert eine Abstrahlung von Wärme nach oben. Diese Geräte bieten die Möglichkeit, ohne Luftbewegung zu heizen. Weiterhin wird die Wärme nur dort bereitgestellt, wo sie gebraucht wird. Durch die kurze Aufheizzeit und eine niedrige Raumtemperatur kann eine hohe Energieeinsparung realisiert werden. Die Deckenstrahlplatten werden in Standardlängen von 4 oder 6 m geliefert. Weiterhin können die Deckenstrahlplatten parallel aufgehängt werden, so dass die Breite aus den Standardbreiten 305 bis 1.300 mm bestehen kann. Standardmäßig ist die Paneele in der Farbe RAL 9010 ausgeführt. Andere RAL-Farben auf Anfrage lieferbar. Produkteigenschaften INFRA AQUA ECO: - einfache Installation / Aufhängung - geringes Gewicht - hohe Wärmeabgabe - Verbindung der Deckenstrahlplatten mit Presskupplungen möglich - gemessen und geprüft gemäß EN 14037 1-3 - Ballwurftest gemäß DIN 18032-3 - Entlüftungsstutzen

Mark Climate Technology

Infra Aqua Eco Deckenstrahlplatte TYPE 1

Die INFRA AQUA ECO ist eine wassergespeiste Deckenstrahlplatte die standardmäßig mit einer Mineralwollisolierung versehen ist. Die Isolierung verhindert eine Abstrahlung von Wärme nach oben. Diese Geräte bieten die Möglichkeit, ohne Luftbewegung zu heizen. Weiterhin wird die Wärme nur dort bereitgestellt, wo sie gebraucht wird. Durch die kurze Aufheizzeit und eine niedrige Raumtemperatur kann eine hohe Energieeinsparung realisiert werden. Die Deckenstrahlplatten werden in Standardlängen von 4 oder 6 m geliefert. Weiterhin können die Deckenstrahlplatten parallel aufgehängt werden, so dass die Breite aus den Standardbreiten 305 bis 1.300 mm bestehen kann. Standardmäßig ist die Paneele in der Farbe RAL 9010 ausgeführt. Andere RAL-Farben auf Anfrage lieferbar. Produkteigenschaften INFRA AQUA ECO: - einfache Installation / Aufhängung - geringes Gewicht - hohe Wärmeabgabe - Verbindung der Deckenstrahlplatten mit Presskupplungen möglich - gemessen und geprüft gemäß EN 14037 1-3 - Ballwurftest gemäß DIN 18032-3 - Entlüftungsstutzen

EMCS-Kompatibilität

.RFA

Heizkörper

Mark Climate Technology

Herunterladen
IVAR Dirtstop® XL

Dirtstop® XL

IVAR Dirtstop® XL: triple effect magnetic dirt separator: cyclonic action guaranteed by a patented internal insert, developed to guide the fluid directed to the boiler in order to maximize the slowing down and decantation of the debris; subsequent removal of ferrous particles by means of a neodymium magnet, magnetic field 14000 G; mechanical filtration with an 800 μm mesh filter (pre- assembled 500 μm filter for the first cleaning of the system). Internal components completely inspectable, removable and washable by removing the upper plug, with the special lever provided. Manual air vent valve. Draining valve with opening lever and tap. Swivel fitting for mounting to the pipeline in different orientations, with the special lever provided. Allowed installation on horizontal, vertical or oblique lines. Buttonhole on magnetic insert, sealing band supplied. Materials: body, cyclonic insert and cap in PA66 + GF 30%; "T" joint and locking ring nut in PA66 + GF 30%; filters in stainless steel AISI 304; seals in peroxide EPDM. Compatible fluids: water; water + glycol max 50%. Maximum recommended flow rate: 2.13 m3/h. Maximum operating pressure: 3 bar. Operating temperature: 0-90 °C. Flow coefficient Kv: 6.7 m3 /h. Connections: Ø22 x Ø22 copper pipe (520124); 3/4" F x 3/4" F (520135); 1"F x 1" F (520136); 1"1/4 F x 1"1/4 F (520139).

IVAR

Dirtstop® XL

IVAR Dirtstop® XL: triple effect magnetic dirt separator: cyclonic action guaranteed by a patented internal insert, developed to guide the fluid directed to the boiler in order to maximize the slowing down and decantation of the debris; subsequent removal of ferrous particles by means of a neodymium magnet, magnetic field 14000 G; mechanical filtration with an 800 μm mesh filter (pre- assembled 500 μm filter for the first cleaning of the system). Internal components completely inspectable, removable and washable by removing the upper plug, with the special lever provided. Manual air vent valve. Draining valve with opening lever and tap. Swivel fitting for mounting to the pipeline in different orientations, with the special lever provided. Allowed installation on horizontal, vertical or oblique lines. Buttonhole on magnetic insert, sealing band supplied. Materials: body, cyclonic insert and cap in PA66 + GF 30%; "T" joint and locking ring nut in PA66 + GF 30%; filters in stainless steel AISI 304; seals in peroxide EPDM. Compatible fluids: water; water + glycol max 50%. Maximum recommended flow rate: 2.13 m3/h. Maximum operating pressure: 3 bar. Operating temperature: 0-90 °C. Flow coefficient Kv: 6.7 m3 /h. Connections: Ø22 x Ø22 copper pipe (520124); 3/4" F x 3/4" F (520135); 1"F x 1" F (520136); 1"1/4 F x 1"1/4 F (520139).

EMCS-Kompatibilität

.RVT .RFA

Steuereinheit für Zentralheizung

IVAR

Herunterladen
IVAR VARIMIX

VARIMIX

Distribution and mixing system IVAR VARIMIX for thermal power stations, modular with: hydraulic separator, modular distribution manifold, high-temperature direct flow kit, low-temperature mixing kit, motor for mixing valves, expansion tank, motor for zone ball zone valves. VARIMIX allows to arrange the mechanical room according to a new concept of space and functionality. This solution gives the opportunity to manage multiple thermal areas with different characteristics as truly independent zones in a neat, rational space, thanks to its modular structure and outstanding installation flexibility. In low temperature kits, the mixer valve is available with different hydraulic features and in 3-way or 4-way versions. By producing a mixture even on the return line, it is particularly suitable for older boilers where the return temperature must not be too low to avoid corrosion. Finally, the “LT” modules are specifically designed for applications with low temperature heat sources (for example, heat pumps). Main features: easy to install; compact and neat; fully reversible; versatile and flexible; suitable for heating and cooling applications. Max primary flow rate: 4500 l/h. Max flow rate for each kit: 3000 l/h.

IVAR

VARIMIX

Distribution and mixing system IVAR VARIMIX for thermal power stations, modular with: hydraulic separator, modular distribution manifold, high-temperature direct flow kit, low-temperature mixing kit, motor for mixing valves, expansion tank, motor for zone ball zone valves. VARIMIX allows to arrange the mechanical room according to a new concept of space and functionality. This solution gives the opportunity to manage multiple thermal areas with different characteristics as truly independent zones in a neat, rational space, thanks to its modular structure and outstanding installation flexibility. In low temperature kits, the mixer valve is available with different hydraulic features and in 3-way or 4-way versions. By producing a mixture even on the return line, it is particularly suitable for older boilers where the return temperature must not be too low to avoid corrosion. Finally, the “LT” modules are specifically designed for applications with low temperature heat sources (for example, heat pumps). Main features: easy to install; compact and neat; fully reversible; versatile and flexible; suitable for heating and cooling applications. Max primary flow rate: 4500 l/h. Max flow rate for each kit: 3000 l/h.

EMCS-Kompatibilität

.RVT .RFA

Verteiler für Zentralheizung

IVAR

Herunterladen
IVAR CI400NR - Modular manifold EASY LOCK series

CI400NR - Modular manifold EASY LOCK series

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves). Modular plain manifold EASY-LOCK series. Manifolds can be used to supply DHW. The body is made of brass CW617N nickel-plated only externally. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 100°C. Maximum operating pressure: 10 bar. Main connections: G 3/4"F or G 1"F. Secondary connections: EUROK or 1/2"M or 1/2"M TP (flat seal). Sizes available: from 2 to 4 ways.

IVAR

CI400NR - Modular manifold EASY LOCK series

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves). Modular plain manifold EASY-LOCK series. Manifolds can be used to supply DHW. The body is made of brass CW617N nickel-plated only externally. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 100°C. Maximum operating pressure: 10 bar. Main connections: G 3/4"F or G 1"F. Secondary connections: EUROK or 1/2"M or 1/2"M TP (flat seal). Sizes available: from 2 to 4 ways.

EMCS-Kompatibilität

.RFA

Formteile für Sanitär und Kanalisation

IVAR

Herunterladen
Aldes Aldes - Quadratische Deckenluftdurchlässe

Aldes - Quadratische Deckenluftdurchlässe

Aldes - Quadratische Deckenluftdurchlässe

Aldes

Aldes - Quadratische Deckenluftdurchlässe

Aldes - Quadratische Deckenluftdurchlässe

 

.Nova

Air terminal

Aldes

Herunterladen
Pichler Lufttechnik LG 150 Deckenmontage

LG 150 Deckenmontage

LG 150 Deckenmontage

Pichler Lufttechnik

LG 150 Deckenmontage

LG 150 Deckenmontage

EMCS-Kompatibilität

.RFA

Ventilaturspule

Pichler Lufttechnik

Herunterladen
KE KELIT KE KELIT KC - Deckenelemente - CLIMATEFIX

KE KELIT KC - Deckenelemente - CLIMATEFIX

KE KELIT KC - Deckenelemente - CLIMATEFIX

KE KELIT

KE KELIT KC - Deckenelemente - CLIMATEFIX

KE KELIT KC - Deckenelemente - CLIMATEFIX

 

.Nova

Strahlungsplatte

KE KELIT

Herunterladen
DINUY S.A. RE DMS DA1/ DM SEN T03

RE DMS DA1/ DM SEN T03

2-Kanal Deckeneinbau-Bewegungsmelder

DINUY S.A.

RE DMS DA1/ DM SEN T03

2-Kanal Deckeneinbau-Bewegungsmelder

EMCS-Kompatibilität

.DWG .RFA .IFC

Detektor

DINUY S.A.

Herunterladen
Hudevad radiator design Hudevad radiator design

Hudevad radiator design

Content for Trimble Nova is available. Please click here for more information.

Hudevad radiator design

Hudevad radiator design

Content for Trimble Nova is available. Please click here for more information.

 

.PDF .Nova

Trimble Nova

Hudevad radiator design

Herunterladen
ABB ABB-tacteo Movement detector 180 FM Standard

ABB-tacteo Movement detector 180 FM Standard

ABB-tacteo Busch-Wächter 180 UP Sensor Standard 

ABB

ABB-tacteo Movement detector 180 FM Standard

ABB-tacteo Busch-Wächter 180 UP Sensor Standard 

EMCS-Kompatibilität

.DWG .RFA .IFC

Detektor

ABB

Herunterladen
KST KST - Deckenstrahlmodule

KST - Deckenstrahlmodule

KST - Deckenstrahlmodule

KST

KST - Deckenstrahlmodule

KST - Deckenstrahlmodule

 

.Nova

Strahlungsplatte

KST

Herunterladen
DINUY S.A. DM TEC 03N

DM TEC 03N

Schwarz Deckenbündiger Bewegungsmelder

DINUY S.A.

DM TEC 03N

Schwarz Deckenbündiger Bewegungsmelder

EMCS-Kompatibilität

.DWG .RFA .IFC

Detektor

DINUY S.A.

Herunterladen
DINUY S.A. DM TEC 004/ DM SEN T03

DM TEC 004/ DM SEN T03

2-Kanal Deckeneinbau-Bewegungsmelder

DINUY S.A.

DM TEC 004/ DM SEN T03

2-Kanal Deckeneinbau-Bewegungsmelder

EMCS-Kompatibilität

.DWG .RFA .IFC

Detektor

DINUY S.A.

Herunterladen
DINUY S.A. DM TEC B1B

DM TEC B1B

360º Bluetooth detector ceiling-mounted white

DINUY S.A.

DM TEC B1B

360º Bluetooth detector ceiling-mounted white

EMCS-Kompatibilität

.DWG .RFA .IFC

Detektor

DINUY S.A.

Herunterladen
DINUY S.A. DM TEC B1P

DM TEC B1P

360º Bluetooth detector ceiling-mounted silver

DINUY S.A.

DM TEC B1P

360º Bluetooth detector ceiling-mounted silver

EMCS-Kompatibilität

.DWG .RFA .IFC

Detektor

DINUY S.A.

Herunterladen
IVAR Fan-Coil Unit Kit

Fan-Coil Unit Kit

IVAR FCU-Kit: Pre-assembled brass multi-function bypass unit for fan-coil systems, chilled beams, heaters and other constant flow rate conditioning systems. Can be used for both heating and cooling. Consisting of: a pair of three-way valves for setting 5 different operating modes, a mesh filter, two loading/unloading taps, a Venturi orifice with a pair of piezometric sockets and a PICV flow regulator. Permissible differential pressure ranges and flow control range (for PICV): with PICC 03 cartridge (code 590123) 16- 200 kPa, 37-575 l/h; with PICC 03 cartridge (code 590124) 30-400 kPa, 64-1110 l/h. Mesh filter (500 μm) in stainless steel AISI 304. Connections to the primary circuit (with unions): 1/2 "F (DN 15) - 3/4 "F (DN 20). Connections to the secondary circuit: 1/2 "F (DN 15) - 3/4 "F (DN 20). Maximum operating pressure: 10 bar. Maximum operating temperature: 120 °C. Available with insulation shell in grey ARPRO 5135 FR with conductivity 0.037 W/mK, density 50 kg/m3, reaction to fire class HF-1 according to UL-94 standard.

IVAR

Fan-Coil Unit Kit

IVAR FCU-Kit: Pre-assembled brass multi-function bypass unit for fan-coil systems, chilled beams, heaters and other constant flow rate conditioning systems. Can be used for both heating and cooling. Consisting of: a pair of three-way valves for setting 5 different operating modes, a mesh filter, two loading/unloading taps, a Venturi orifice with a pair of piezometric sockets and a PICV flow regulator. Permissible differential pressure ranges and flow control range (for PICV): with PICC 03 cartridge (code 590123) 16- 200 kPa, 37-575 l/h; with PICC 03 cartridge (code 590124) 30-400 kPa, 64-1110 l/h. Mesh filter (500 μm) in stainless steel AISI 304. Connections to the primary circuit (with unions): 1/2 "F (DN 15) - 3/4 "F (DN 20). Connections to the secondary circuit: 1/2 "F (DN 15) - 3/4 "F (DN 20). Maximum operating pressure: 10 bar. Maximum operating temperature: 120 °C. Available with insulation shell in grey ARPRO 5135 FR with conductivity 0.037 W/mK, density 50 kg/m3, reaction to fire class HF-1 according to UL-94 standard.

EMCS-Kompatibilität

.RVT .RFA

Ventilaturspule

IVAR

Herunterladen
IVAR TECHNOMIX

TECHNOMIX

IVAR TECHNO TNB cod. 508100: mixing and boosting unit for radiant installations complete with two-way mixing valve, balancing valve (on the cold way), fill/drain valve, manual air vent valve, two thermometers 0÷80 °C (on delivery of boiler circuit and mixed circuit), temperature sensor pocket (on delivery of mixed circuit), shut off valve (on return of boiler circuit), boiler circuit connections G 1”F (centre distance 200 mm) and mixed circuit connections G 1”M (centre distance 200 mm). Upper and lower parts made of nickel-plated CB753S brass; pipe made of nickel-plated half-hard copper; gaskets and O-rings made of peroxide-cured EPDM; other parts made of CW617N brass. Max operating temperature 100 °C. Max operating pressure 10 bar. Fixed point mixing 20÷60 °C by thermostatic control head with remote sensor T3011 included. Max differential pressure at mixing valve ends 250 mbar. Pump space 130 mm with G 1”1/2F flat seal connections.

IVAR

TECHNOMIX

IVAR TECHNO TNB cod. 508100: mixing and boosting unit for radiant installations complete with two-way mixing valve, balancing valve (on the cold way), fill/drain valve, manual air vent valve, two thermometers 0÷80 °C (on delivery of boiler circuit and mixed circuit), temperature sensor pocket (on delivery of mixed circuit), shut off valve (on return of boiler circuit), boiler circuit connections G 1”F (centre distance 200 mm) and mixed circuit connections G 1”M (centre distance 200 mm). Upper and lower parts made of nickel-plated CB753S brass; pipe made of nickel-plated half-hard copper; gaskets and O-rings made of peroxide-cured EPDM; other parts made of CW617N brass. Max operating temperature 100 °C. Max operating pressure 10 bar. Fixed point mixing 20÷60 °C by thermostatic control head with remote sensor T3011 included. Max differential pressure at mixing valve ends 250 mbar. Pump space 130 mm with G 1”1/2F flat seal connections.

EMCS-Kompatibilität

.RVT .RFA

Verteiler für Zentralheizung

IVAR

Herunterladen
Mark Climate Technology Infra Aqua Eco Deckenstrahlplatte TYPE 3

Infra Aqua Eco Deckenstrahlplatte TYPE 3

Die INFRA AQUA ECO ist eine wassergespeiste Deckenstrahlplatte die standardmäßig mit einer Mineralwollisolierung versehen ist. Die Isolierung verhindert eine Abstrahlung von Wärme nach oben. Diese Geräte bieten die Möglichkeit, ohne Luftbewegung zu heizen. Weiterhin wird die Wärme nur dort bereitgestellt, wo sie gebraucht wird. Durch die kurze Aufheizzeit und eine niedrige Raumtemperatur kann eine hohe Energieeinsparung realisiert werden. Die Deckenstrahlplatten werden in Standardlängen von 4 oder 6 m geliefert. Weiterhin können die Deckenstrahlplatten parallel aufgehängt werden, so dass die Breite aus den Standardbreiten 305 bis 1.300 mm bestehen kann. Standardmäßig ist die Paneele in der Farbe RAL 9010 ausgeführt. Andere RAL-Farben auf Anfrage lieferbar. Produkteigenschaften INFRA AQUA ECO: - einfache Installation / Aufhängung - geringes Gewicht - hohe Wärmeabgabe - Verbindung der Deckenstrahlplatten mit Presskupplungen möglich - gemessen und geprüft gemäß EN 14037 1-3 - Ballwurftest gemäß DIN 18032-3 - Entlüftungsstutzen

Mark Climate Technology

Infra Aqua Eco Deckenstrahlplatte TYPE 3

Die INFRA AQUA ECO ist eine wassergespeiste Deckenstrahlplatte die standardmäßig mit einer Mineralwollisolierung versehen ist. Die Isolierung verhindert eine Abstrahlung von Wärme nach oben. Diese Geräte bieten die Möglichkeit, ohne Luftbewegung zu heizen. Weiterhin wird die Wärme nur dort bereitgestellt, wo sie gebraucht wird. Durch die kurze Aufheizzeit und eine niedrige Raumtemperatur kann eine hohe Energieeinsparung realisiert werden. Die Deckenstrahlplatten werden in Standardlängen von 4 oder 6 m geliefert. Weiterhin können die Deckenstrahlplatten parallel aufgehängt werden, so dass die Breite aus den Standardbreiten 305 bis 1.300 mm bestehen kann. Standardmäßig ist die Paneele in der Farbe RAL 9010 ausgeführt. Andere RAL-Farben auf Anfrage lieferbar. Produkteigenschaften INFRA AQUA ECO: - einfache Installation / Aufhängung - geringes Gewicht - hohe Wärmeabgabe - Verbindung der Deckenstrahlplatten mit Presskupplungen möglich - gemessen und geprüft gemäß EN 14037 1-3 - Ballwurftest gemäß DIN 18032-3 - Entlüftungsstutzen

EMCS-Kompatibilität

.RFA

Heizkörper

Mark Climate Technology

Herunterladen
Esser IQ8MCP Large

IQ8MCP Large

Manual Fire Detector

Esser

IQ8MCP Large

Manual Fire Detector

EMCS-Kompatibilität

.DWG .RFA .IFC

Detektor

Esser

Herunterladen
IVAR CI350N - Modular manifold EASY LOCK series

CI350N - Modular manifold EASY LOCK series

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves). Modular plain manifold EASY LOCK series. Manifolds can be used to supply DCW or DHW. The body is made of brass CW617N nickel-plated only externally. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 100°C. Maximum operating pressure: 10 bar. Main connections: G 3/4"F or G 1"F. Secondary connections: EUROK or 1/2"M or 1/2"M TP (flat seal). Sizes available: from 2 to 5 ways.

IVAR

CI350N - Modular manifold EASY LOCK series

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves). Modular plain manifold EASY LOCK series. Manifolds can be used to supply DCW or DHW. The body is made of brass CW617N nickel-plated only externally. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 100°C. Maximum operating pressure: 10 bar. Main connections: G 3/4"F or G 1"F. Secondary connections: EUROK or 1/2"M or 1/2"M TP (flat seal). Sizes available: from 2 to 5 ways.

EMCS-Kompatibilität

.RFA

Formteile für Sanitär und Kanalisation

IVAR

Herunterladen
DINUY S.A. RE DMS DA3/ DM SEN T03

RE DMS DA3/ DM SEN T03

2-Kanal Deckeneinbau-Bewegungsmelder

DINUY S.A.

RE DMS DA3/ DM SEN T03

2-Kanal Deckeneinbau-Bewegungsmelder

EMCS-Kompatibilität

.DWG .RFA .IFC

Detektor

DINUY S.A.

Herunterladen
DINUY S.A. DM TEC 01P

DM TEC 01P

Silber Bewegungsmelder für Deckenmontage

DINUY S.A.

DM TEC 01P

Silber Bewegungsmelder für Deckenmontage

EMCS-Kompatibilität

.DWG .RFA .IFC

Detektor

DINUY S.A.

Herunterladen
DINUY S.A. DP TEC 01N

DP TEC 01N

Präsenzmelder zur Deckenmontage

DINUY S.A.

DP TEC 01N

Präsenzmelder zur Deckenmontage

EMCS-Kompatibilität

.DWG .RFA .IFC

Detektor

DINUY S.A.

Herunterladen
DINUY S.A. DP TEC 03N

DP TEC 03N

Präsenzmelder für den deckenbündigen Einbau

DINUY S.A.

DP TEC 03N

Präsenzmelder für den deckenbündigen Einbau

EMCS-Kompatibilität

.DWG .RFA .IFC

Detektor

DINUY S.A.

Herunterladen
Depping AG Depping AG

Depping AG

Content for Trimble Nova is available. Please click here for more information.

Depping AG

Depping AG

Content for Trimble Nova is available. Please click here for more information.

 

.PDF .Nova

Trimble Nova

Depping AG

Herunterladen
DINUY S.A. DM TE1 DA2/ DM SEN T03

DM TE1 DA2/ DM SEN T03

2-Kanal Deckeneinbau-Bewegungsmelder

DINUY S.A.

DM TE1 DA2/ DM SEN T03

2-Kanal Deckeneinbau-Bewegungsmelder

EMCS-Kompatibilität

.DWG .RFA .IFC

Detektor

DINUY S.A.

Herunterladen
DINUY S.A. DM TEC 01N

DM TEC 01N

Schwarz Bewegungsmelder für Deckenmontage

DINUY S.A.

DM TEC 01N

Schwarz Bewegungsmelder für Deckenmontage

EMCS-Kompatibilität

.DWG .RFA .IFC

Detektor

DINUY S.A.

Herunterladen
DINUY S.A. RE DMS 003/ DM SEN T03

RE DMS 003/ DM SEN T03

2-Kanal Deckeneinbau-Bewegungsmelder

DINUY S.A.

RE DMS 003/ DM SEN T03

2-Kanal Deckeneinbau-Bewegungsmelder

EMCS-Kompatibilität

.DWG .RFA .IFC

Detektor

DINUY S.A.

Herunterladen
DeLonghi DeLonghi

DeLonghi

Content for Trimble Nova is available. Please click here for more information.

DeLonghi

DeLonghi

Content for Trimble Nova is available. Please click here for more information.

 

.PDF .Nova

Trimble Nova

DeLonghi

Herunterladen
Esser IQ8MCP

IQ8MCP

Manual Fire Detector

Esser

IQ8MCP

Manual Fire Detector

EMCS-Kompatibilität

.RFA

Detektor

Esser

Herunterladen
KST KST - Vollflächige Decken

KST - Vollflächige Decken

KST - Vollflächige Decken

KST

KST - Vollflächige Decken

KST - Vollflächige Decken

 

.Nova

Strahlungsplatte

KST

Herunterladen
DINUY S.A. DM KNT 001

DM KNT 001

KNX-Bewegungsmelder für Deckenmontage

DINUY S.A.

DM KNT 001

KNX-Bewegungsmelder für Deckenmontage

EMCS-Kompatibilität

.DWG .RFA .IFC

Detektor

DINUY S.A.

Herunterladen
DINUY S.A. DM TEC 002/ DM SEN T03

DM TEC 002/ DM SEN T03

2-Kanal Deckeneinbau-Bewegungsmelder

DINUY S.A.

DM TEC 002/ DM SEN T03

2-Kanal Deckeneinbau-Bewegungsmelder

EMCS-Kompatibilität

.DWG .RFA .IFC

Detektor

DINUY S.A.

Herunterladen
DINUY S.A. DM SEN T03

DM SEN T03

Flush-ceiling mounted slave motion detector

DINUY S.A.

DM SEN T03

Flush-ceiling mounted slave motion detector

EMCS-Kompatibilität

.DWG .RFA .IFC

Detektor

DINUY S.A.

Herunterladen
DINUY S.A. DP TEC 03P

DP TEC 03P

Präsenzmelder für den deckenbündigen Einbau

DINUY S.A.

DP TEC 03P

Präsenzmelder für den deckenbündigen Einbau

EMCS-Kompatibilität

.DWG .RFA .IFC

Detektor

DINUY S.A.

Herunterladen
IVAR AC628 - Double bracket for EASY LOCK modular manifolds

AC628 - Double bracket for EASY LOCK modular manifolds

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves). Double bracket for EASY LOCK modular manifolds. Made of zinc plated steel. Axle spacing: 200 mm. Two different sizes: DN 20 or DN 25.

IVAR

AC628 - Double bracket for EASY LOCK modular manifolds

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves).

Double bracket for EASY LOCK modular manifolds. Made of zinc plated steel. Axle spacing: 200 mm. Two different sizes: DN 20 or DN 25.

EMCS-Kompatibilität

.RFA

Formteile für Sanitär und Kanalisation

IVAR

Herunterladen
DINUY S.A. DM TEC 003

DM TEC 003

Weiß Deckenbündiger Bewegungsmelder

DINUY S.A.

DM TEC 003

Weiß Deckenbündiger Bewegungsmelder

EMCS-Kompatibilität

.DWG .RFA .IFC

Detektor

DINUY S.A.

Herunterladen
Halton Halton - Küchenlüftungshaube mit der Capture Jet™-Technologie und integrierter Zuluft

Halton - Küchenlüftungshaube mit der Capture Jet™-Technologie und integrierter Zuluft

Halton - Küchenlüftungshaube mit der Capture Jet™-Technologie und integrierter Zuluft

Halton

Halton - Küchenlüftungshaube mit der Capture Jet™-Technologie und integrierter Zuluft

Halton - Küchenlüftungshaube mit der Capture Jet™-Technologie und integrierter Zuluft

 

.Nova

Abzugshaube

Halton

Herunterladen
DINUY S.A. DP TEC 001

DP TEC 001

Präsenzmelder zur Deckenmontage

DINUY S.A.

DP TEC 001

Präsenzmelder zur Deckenmontage

EMCS-Kompatibilität

.DWG .RFA .IFC

Detektor

DINUY S.A.

Herunterladen
Renson Flex Design

Flex Design

Flex design roof outlet

Renson

Flex Design

Flex design roof outlet

EMCS-Kompatibilität

.RFA

Dachlüfter

Renson

Herunterladen
IVAR AC639 - Single bracket or EASY LOCK modular manifolds

AC639 - Single bracket or EASY LOCK modular manifolds

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves). Single bracket for EASY LOCK modular manifolds. Made of zinc plated steel. Two different sizes: DN 20 or DN 25.

IVAR

AC639 - Single bracket or EASY LOCK modular manifolds

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves).

Single bracket for EASY LOCK modular manifolds. Made of zinc plated steel. Two different sizes: DN 20 or DN 25.

EMCS-Kompatibilität

.RFA

Formteile für Sanitär und Kanalisation

IVAR

Herunterladen
Mark Climate Technology Ceilfit Deckensegel

Ceilfit Deckensegel

Das Mark CEILFIT-Deckensegel schafft durch Konvektion und Strahlung ein komfortables Arbeits- und Wohnumfeld. Zonen oder Räume können einfach individuell gekühlt oder beheizt werden. Die Deckensegel sind zum Einbau in eine Systemdecke geeignet und können Standardfliesen ohne zusätzliche Arbeiten an den Profilen ersetzen. Die Deckensegel sind in handelsüblichen Rasterabmessungen oder auf Anfrage in benutzerdefinierten Abmessungen erhältlich. Merkmale - Eeinfache Installation in Standard-Systemdecken - Kosteneffizientes Heizen und Kühlen - RAL 9010 lackiert - 0,7 mm pulverbeschichteten Stahlblech - Präzisionsrohr von 10 x 0,4mm hält Drücken von bis zu 6 bar stand - leicht zu reinigen - freie Wand- und Bodenflächen - schnelle Erwärmung durch geringes Wasservolumen - geringer wasserseitiger Druckverlust - keine Wartung - Entsprechen der Norm NEN-EN 13964 - Optional: mit Perforation für eine bessere Schallabsorption Wir empfehlen die Deckensegel an der Decke zu montieren. Serienmäßig sind die Deckensegel bereits mit Bohrungen für Aufhängungen und Kabel versehen.

Mark Climate Technology

Ceilfit Deckensegel

Das Mark CEILFIT-Deckensegel schafft durch Konvektion und Strahlung ein komfortables Arbeits- und Wohnumfeld. Zonen oder Räume können einfach individuell gekühlt oder beheizt werden. Die Deckensegel sind zum Einbau in eine Systemdecke geeignet und können Standardfliesen ohne zusätzliche Arbeiten an den Profilen ersetzen. Die Deckensegel sind in handelsüblichen Rasterabmessungen oder auf Anfrage in benutzerdefinierten Abmessungen erhältlich. Merkmale - Eeinfache Installation in Standard-Systemdecken - Kosteneffizientes Heizen und Kühlen - RAL 9010 lackiert - 0,7 mm pulverbeschichteten Stahlblech - Präzisionsrohr von 10 x 0,4mm hält Drücken von bis zu 6 bar stand - leicht zu reinigen - freie Wand- und Bodenflächen - schnelle Erwärmung durch geringes Wasservolumen - geringer wasserseitiger Druckverlust - keine Wartung - Entsprechen der Norm NEN-EN 13964 - Optional: mit Perforation für eine bessere Schallabsorption Wir empfehlen die Deckensegel an der Decke zu montieren. Serienmäßig sind die Deckensegel bereits mit Bohrungen für Aufhängungen und Kabel versehen.

EMCS-Kompatibilität

.DWG .RFA .IFC

Heizkörper

Mark Climate Technology

Herunterladen
DINUY S.A. DM TEC B3B

DM TEC B3B

360º Bluetooth detector flush ceiling mounting white

DINUY S.A.

DM TEC B3B

360º Bluetooth detector flush ceiling mounting white

EMCS-Kompatibilität

.DWG .RFA .IFC

Detektor

DINUY S.A.

Herunterladen
DINUY S.A. DP TEC 003

DP TEC 003

Präsenzmelder für den deckenbündigen Einbau

DINUY S.A.

DP TEC 003

Präsenzmelder für den deckenbündigen Einbau

EMCS-Kompatibilität

.DWG .RFA .IFC

Detektor

DINUY S.A.

Herunterladen
Zehnder Group International AG ZFP Ceiling Panel (family)

ZFP Ceiling Panel (family)

Heating/cooling panels from Zehnder. This article is highly configurable in Revit to support thousands of combinations. See the PDF manual for details (recommended). Separate families for the hanging system, flow- and return valves and LED luminaire are also available for download from this page.

Zehnder Group International AG

ZFP Ceiling Panel (family)

Heating/cooling panels from Zehnder. This article is highly configurable in Revit to support thousands of combinations. See the PDF manual for details (recommended). Separate families for the hanging system, flow- and return valves and LED luminaire are also available for download from this page.

EMCS-Kompatibilität

.RFA .PDF

Heizkörper

Zehnder Group International AG

Herunterladen