Mitsubishi Electric Mitsubishi Electric System Designer

Mitsubishi Electric System Designer

Find quickly Mitsubishi Electric content and place it directly in Revit or Autocad with this free App. The Mitsubishi Electric System Designer App for Revit and AutoCAD is a powerful tool allowing you to find the right Mitsubishi Electric Revit families and CAD files for heating and cooling units that you need. Filter the Mitsubishi Electric HVAC units on technical properties or search on article number, description, model or series and use your desired air conditioners in your BIM projects instantly. The following product series are available in the app: City Multi, Ecodan, E-series, Lossnay, M Series, Mr. Slim. Download the free app now! You can download the app for free from [a href="https://store.mepcontent.com/Product/Details/49" target="_blank"]our store[/a].

Mitsubishi Electric

Mitsubishi Electric System Designer

Find quickly Mitsubishi Electric content and place it directly in Revit or Autocad with this free App. The Mitsubishi Electric System Designer App for Revit and AutoCAD is a powerful tool allowing you to find the right Mitsubishi Electric Revit families and CAD files for heating and cooling units that you need. Filter the Mitsubishi Electric HVAC units on technical properties or search on article number, description, model or series and use your desired air conditioners in your BIM projects instantly. The following product series are available in the app: City Multi, Ecodan, E-series, Lossnay, M Series, Mr. Slim. Download the free app now! You can download the app for free from [a href="https://store.mepcontent.com/Product/Details/49" target="_blank"]our store[/a].

EMCS-Kompatibilität

.PDF

Klimaanlage

Mitsubishi Electric

Herunterladen
Remeha Tzerra HP

Tzerra HP

Boiler

Remeha

Tzerra HP

Boiler

EMCS-Kompatibilität

.DWG .RFA .IFC

Kessel

Remeha

Herunterladen
IVAR PICV 00-05-10 With PICC 01-02-03

PICV 00-05-10 With PICC 01-02-03

Valve that keeps the flow rate constant during operation within a certain differential pressure range thanks to a membrane device with a contrast spring. Complete with two pockets G 1/4"F for piezometric sockets (IVAR AVB 10) and with plugs for piezometric sockets and cartridge. PICV 00 (female) connections: G 1/2"F, G 3/4"F, G 1"F in compliance with ISO 228/1. PICV 05 (male - flat seal) connections: G 3/4"M, EUROK, G 1"M, G 1"1/4M in compliance with ISO 228/1. PICV 10 (with unions) connections: G 1/2"M, G 3/4"M, G 1"M in compliance with ISO 228/1 and EN 10226-1. To combine with PICC 01, PICC 02 or PICC 03 cartridges. PICC connection: M32x1.5. Compatible with water or glycol solutions max 30%. Min operating temperature: -20 °C. Max operating temperature: 120 °C. Max operating pressure: 25 bar. Max closing pressure with PICC 03: 6 bar. Valve material: CW617N brass. Sealing gaskets material: Peroxide EPDM. IVAR PICC 01: 8 flow rate ranges to set; brass and POM insert; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets. IVAR PICC 02: 41 flow rate ranges to set even during operation; brass and PSU insert; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets. IVAR PICC 03: 41 flow rate ranges to set even during operation; to combine with IVAR TE 3003 electrothermal actuator (M30x1.5; ON/OFF 230 V AC or ON/OFF 24 V AC or proportional 0-10 V 24 V AC adjustment) or IVAR RV 03 axial motor (M30x1.5; 2 points/3 points 230 V AC or 2 points/3 points 24 V AC or proportional 0-10 V 24 V AC adjustment); max closing pressure 6 bar; brass and PSU/POM/PPS (glass-fibre reinforced) insert; stainless steel internal metal components; PPS/Peroxide EPDM cone; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets.

IVAR

PICV 00-05-10 With PICC 01-02-03

Valve that keeps the flow rate constant during operation within a certain differential pressure range thanks to a membrane device with a contrast spring. Complete with two pockets G 1/4"F for piezometric sockets (IVAR AVB 10) and with plugs for piezometric sockets and cartridge. PICV 00 (female) connections: G 1/2"F, G 3/4"F, G 1"F in compliance with ISO 228/1. PICV 05 (male - flat seal) connections: G 3/4"M, EUROK, G 1"M, G 1"1/4M in compliance with ISO 228/1. PICV 10 (with unions) connections: G 1/2"M, G 3/4"M, G 1"M in compliance with ISO 228/1 and EN 10226-1. To combine with PICC 01, PICC 02 or PICC 03 cartridges. PICC connection: M32x1.5. Compatible with water or glycol solutions max 30%. Min operating temperature: -20 °C. Max operating temperature: 120 °C. Max operating pressure: 25 bar. Max closing pressure with PICC 03: 6 bar. Valve material: CW617N brass. Sealing gaskets material: Peroxide EPDM. IVAR PICC 01: 8 flow rate ranges to set; brass and POM insert; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets. IVAR PICC 02: 41 flow rate ranges to set even during operation; brass and PSU insert; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets. IVAR PICC 03: 41 flow rate ranges to set even during operation; to combine with IVAR TE 3003 electrothermal actuator (M30x1.5; ON/OFF 230 V AC or ON/OFF 24 V AC or proportional 0-10 V 24 V AC adjustment) or IVAR RV 03 axial motor (M30x1.5; 2 points/3 points 230 V AC or 2 points/3 points 24 V AC or proportional 0-10 V 24 V AC adjustment); max closing pressure 6 bar; brass and PSU/POM/PPS (glass-fibre reinforced) insert; stainless steel internal metal components; PPS/Peroxide EPDM cone; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets.

EMCS-Kompatibilität

.RFA

Ventil für Heizung und Kühlung

IVAR

Herunterladen
IVAR PICV 200-205-210 With PICC 22

PICV 200-205-210 With PICC 22

Valve that keeps the flow rate constant during operation within a certain differential pressure range thanks to a membrane device with a contrast spring. Complete with two pockets G 1/4"F for piezometric sockets (IVAR AVB 10) and with plugs for piezometric sockets and cartridge. PICV 200 (female) connections: G 1"1/2F, G 2"F in compliance with ISO 228/1. PICV 205 (male - flat seal) connections: G 2"M, G 2"1/2M in compliance with ISO 228/1. PICV 210 (with unions) connections: G 1"1/2M, G 2"M in compliance with ISO 228/1 and EN 10226-1. To combine with PICC 22 cartridge. PICC connection: W81x16. Compatible with water or glycol solutions max 30%. Min operating temperature: -20 °C. Max operating temperature: 120 °C. Max operating pressure: 25 bar. Valve material: CW617N brass. Sealing gaskets material: Peroxide EPDM. IVAR PICC 22: 41 flow rate ranges to set even during operation; brass and PSU insert; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets.

IVAR

PICV 200-205-210 With PICC 22

Valve that keeps the flow rate constant during operation within a certain differential pressure range thanks to a membrane device with a contrast spring. Complete with two pockets G 1/4"F for piezometric sockets (IVAR AVB 10) and with plugs for piezometric sockets and cartridge. PICV 200 (female) connections: G 1"1/2F, G 2"F in compliance with ISO 228/1. PICV 205 (male - flat seal) connections: G 2"M, G 2"1/2M in compliance with ISO 228/1. PICV 210 (with unions) connections: G 1"1/2M, G 2"M in compliance with ISO 228/1 and EN 10226-1. To combine with PICC 22 cartridge. PICC connection: W81x16. Compatible with water or glycol solutions max 30%. Min operating temperature: -20 °C. Max operating temperature: 120 °C. Max operating pressure: 25 bar. Valve material: CW617N brass. Sealing gaskets material: Peroxide EPDM. IVAR PICC 22: 41 flow rate ranges to set even during operation; brass and PSU insert; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets.

EMCS-Kompatibilität

.RFA

Ventil für Heizung und Kühlung

IVAR

Herunterladen
IVAR PICV 100-105-110 With PICC 11-12-13

PICV 100-105-110 With PICC 11-12-13

Valve that keeps the flow rate constant during operation within a certain differential pressure range thanks to a membrane device with a contrast spring. Complete with two pockets G 1/4"F for piezometric sockets (IVAR AVB 10) and with plugs for piezometric sockets and cartridge. PICV 100 (female) connections: G 1"F, G 1"1/4F in compliance with ISO 228/1. PICV 105 (male - flat seal) connections: G 1"M, G 1"1/4M, G 1"1/2M in compliance with ISO 228/1. PICV 110 (with unions) connections: G 3/4"M, G 1"M, G 1"1/4M in compliance with ISO 228/1 and EN 10226-1. To combine with PICC 11, PICC 12 or PICC 13 cartridges. PICC connection: M54x1.5. Compatible with water or glycol solutions max 30%. Min operating temperature: -20 °C. Max operating temperature: 120 °C. Max operating pressure: 25 bar. Max closing pressure with PICC 13: 4 bar. Valve material: CW617N brass. Sealing gaskets material: Peroxide EPDM. IVAR PICC 11: 8 flow rate ranges to set; brass and POM insert; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets. IVAR PICC 12: 41 flow rate ranges to set even during operation; brass and PSU insert; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets. IVAR PICC 13: 41 flow rate ranges to set even during operation; to combine with IVAR RV 03 axial motor (M30x1.5; 2 points/3 points 230 V AC or 2 points/3 points 24 V AC or proportional 0-10 V 24 V AC adjustment); max closing pressure 4 bar; brass and PSU/POM/PPS (glass-fibre reinforced) insert; stainless steel internal metal components; PPS/Peroxide EPDM cone; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets.

IVAR

PICV 100-105-110 With PICC 11-12-13

Valve that keeps the flow rate constant during operation within a certain differential pressure range thanks to a membrane device with a contrast spring. Complete with two pockets G 1/4"F for piezometric sockets (IVAR AVB 10) and with plugs for piezometric sockets and cartridge. PICV 100 (female) connections: G 1"F, G 1"1/4F in compliance with ISO 228/1. PICV 105 (male - flat seal) connections: G 1"M, G 1"1/4M, G 1"1/2M in compliance with ISO 228/1. PICV 110 (with unions) connections: G 3/4"M, G 1"M, G 1"1/4M in compliance with ISO 228/1 and EN 10226-1. To combine with PICC 11, PICC 12 or PICC 13 cartridges. PICC connection: M54x1.5. Compatible with water or glycol solutions max 30%. Min operating temperature: -20 °C. Max operating temperature: 120 °C. Max operating pressure: 25 bar. Max closing pressure with PICC 13: 4 bar. Valve material: CW617N brass. Sealing gaskets material: Peroxide EPDM. IVAR PICC 11: 8 flow rate ranges to set; brass and POM insert; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets. IVAR PICC 12: 41 flow rate ranges to set even during operation; brass and PSU insert; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets. IVAR PICC 13: 41 flow rate ranges to set even during operation; to combine with IVAR RV 03 axial motor (M30x1.5; 2 points/3 points 230 V AC or 2 points/3 points 24 V AC or proportional 0-10 V 24 V AC adjustment); max closing pressure 4 bar; brass and PSU/POM/PPS (glass-fibre reinforced) insert; stainless steel internal metal components; PPS/Peroxide EPDM cone; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets.

EMCS-Kompatibilität

.RFA

Ventil für Heizung und Kühlung

IVAR

Herunterladen
IVAR IVARSAT-L-LE

IVARSAT-L-LE

Satellite module that independently manages low-temperature heating (mixed circuit) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; mixing valve for fixed point mixing (with thermostatic control head and remote contact probe) or outside compensated temperature mixing (with axial servomotor and control unit); three-speed pump / model “E” with variable-speed pump EEI<20; summer/winter two-way valve; pocket for temperature immersion probe on delivery side of primary circuit; balancing valve on primary circuit; balancing by-pass valve on mixed circuit; balancing lockshield of heating/domestic water circuit; hydraulic separator with built-in check valve; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. Model “1” with high-temperature domestic water outlet. Model “R” with hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor.

IVAR

IVARSAT-L-LE

Satellite module that independently manages low-temperature heating (mixed circuit) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; mixing valve for fixed point mixing (with thermostatic control head and remote contact probe) or outside compensated temperature mixing (with axial servomotor and control unit); three-speed pump / model “E” with variable-speed pump EEI<20; summer/winter two-way valve; pocket for temperature immersion probe on delivery side of primary circuit; balancing valve on primary circuit; balancing by-pass valve on mixed circuit; balancing lockshield of heating/domestic water circuit; hydraulic separator with built-in check valve; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. Model “1” with high-temperature domestic water outlet. Model “R” with hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor.

EMCS-Kompatibilität

.RFA

Verteiler für Zentralheizung

IVAR

Herunterladen
IVAR IVARSAT-HL-HLE

IVARSAT-HL-HLE

Satellite module that independently manages high-temperature and low-temperature heating (direct and mixed circuits) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; mixing valve for fixed point mixing (with thermostatic control head and remote contact probe) or outside compensated temperature mixing (with axial servomotor and control unit); three-speed pump / model “E” with variable-speed pump EEI<20; summer/winter two-way valve on high-temperature and low-temperature circuits; pocket for temperature immersion probe on delivery side of primary circuit; balancing valve on primary circuit; balancing by-pass valve on mixed circuit; balancing lockshield of heating/domestic water circuit; hydraulic separator with built-in check valve; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. High-temperature domestic water outlet. Hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor.

IVAR

IVARSAT-HL-HLE

Satellite module that independently manages high-temperature and low-temperature heating (direct and mixed circuits) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; mixing valve for fixed point mixing (with thermostatic control head and remote contact probe) or outside compensated temperature mixing (with axial servomotor and control unit); three-speed pump / model “E” with variable-speed pump EEI<20; summer/winter two-way valve on high-temperature and low-temperature circuits; pocket for temperature immersion probe on delivery side of primary circuit; balancing valve on primary circuit; balancing by-pass valve on mixed circuit; balancing lockshield of heating/domestic water circuit; hydraulic separator with built-in check valve; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. High-temperature domestic water outlet. Hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor.

EMCS-Kompatibilität

.RFA

Verteiler für Zentralheizung

IVAR

Herunterladen
IVAR IVARSAT-H

IVARSAT-H

Satellite module that independently manages high-temperature heating (direct circuit) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; domestic water preheating device; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; summer/winter two-way valve; pocket for temperature immersion probe on delivery side of primary circuit; balancing lockshield of primary circuit with double micrometrical adjustment; balancing lockshield of heating/domestic water circuit; differential overpressure by-pass valve on primary circuit; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. Model “1” with high-temperature domestic water outlet. Model “R” with hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor.

IVAR

IVARSAT-H

Satellite module that independently manages high-temperature heating (direct circuit) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; domestic water preheating device; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; summer/winter two-way valve; pocket for temperature immersion probe on delivery side of primary circuit; balancing lockshield of primary circuit with double micrometrical adjustment; balancing lockshield of heating/domestic water circuit; differential overpressure by-pass valve on primary circuit; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. Model “1” with high-temperature domestic water outlet. Model “R” with hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor.

EMCS-Kompatibilität

.RFA

Verteiler für Zentralheizung

IVAR

Herunterladen
IVAR IVARSAT-H VNR

IVARSAT-H VNR

Satellite module that independently manages high-temperature heating (direct circuit) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; domestic water preheating device; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; summer/winter two-way valve; pocket for temperature immersion probe on delivery side of primary circuit; balancing lockshield of primary circuit with double micrometrical adjustment; balancing lockshield of heating/domestic water circuit; differential overpressure by-pass valve on primary circuit; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. Model “1” with high-temperature domestic water outlet. Model “R” with hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor. In compliance with Belgaqua.

IVAR

IVARSAT-H VNR

Satellite module that independently manages high-temperature heating (direct circuit) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; domestic water preheating device; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; summer/winter two-way valve; pocket for temperature immersion probe on delivery side of primary circuit; balancing lockshield of primary circuit with double micrometrical adjustment; balancing lockshield of heating/domestic water circuit; differential overpressure by-pass valve on primary circuit; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. Model “1” with high-temperature domestic water outlet. Model “R” with hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor. In compliance with Belgaqua.

EMCS-Kompatibilität

.RFA

Verteiler für Zentralheizung

IVAR

Herunterladen
Hisense AVC-05-19

AVC-05-19

Mini 4-Way Cassette

Hisense

AVC-05-19

Mini 4-Way Cassette

EMCS-Kompatibilität

.DWG .RFA .IFC

Klimaanlage

Hisense

Herunterladen
ELCO Trigon XXL EVO

Trigon XXL EVO

System Boiler

ELCO

Trigon XXL EVO

System Boiler

EMCS-Kompatibilität

.DWG .RFA .IFC

Kessel

ELCO

Herunterladen
ELCO Trigon XXL SE

Trigon XXL SE

System Boiler

ELCO

Trigon XXL SE

System Boiler

EMCS-Kompatibilität

.DWG .RFA .IFC

Kessel

ELCO

Herunterladen
KSB KSB

KSB

KSB-Umwälzpunpen

KSB

KSB

KSB-Umwälzpunpen

.PLS für Stabicad

Zentralheizung

KSB

Ansicht
ABB ClimaEco Raumtemperaturregler, 6fach

ClimaEco Raumtemperaturregler, 6fach

ABB ClimaEco Raumtemperaturregler, 6fach

ABB

ClimaEco Raumtemperaturregler, 6fach

ABB ClimaEco Raumtemperaturregler, 6fach

EMCS-Kompatibilität

.DWG .RFA .IFC

Steuereinheit für Zentralheizung

ABB

Herunterladen
ABB ClimaEco Bedienelement 8-fach 

ClimaEco Bedienelement 8-fach 

ABB ClimaEco Bedienelement 8-fach 

ABB

ClimaEco Bedienelement 8-fach 

ABB ClimaEco Bedienelement 8-fach 

EMCS-Kompatibilität

.DWG .RFA .IFC

Steuereinheit für Zentralheizung

ABB

Herunterladen
ABB ClimaEco Raumtemperaturregler 10-fach

ClimaEco Raumtemperaturregler 10-fach

ABB ClimaEco Raumtemperaturregler 10-fach

ABB

ClimaEco Raumtemperaturregler 10-fach

ABB ClimaEco Raumtemperaturregler 10-fach

EMCS-Kompatibilität

.DWG .RFA .IFC

Steuereinheit für Zentralheizung

ABB

Herunterladen
ELCO Trigon XXL ECO

Trigon XXL ECO

System Boiler

ELCO

Trigon XXL ECO

System Boiler

EMCS-Kompatibilität

.DWG .RFA .IFC

Kessel

ELCO

Herunterladen
ABB ClimaEco Bedienelement 12-fach 

ClimaEco Bedienelement 12-fach 

ABB ClimaEco Bedienelement 12-fach 

ABB

ClimaEco Bedienelement 12-fach 

ABB ClimaEco Bedienelement 12-fach 

EMCS-Kompatibilität

.DWG .RFA .IFC

Steuereinheit für Zentralheizung

ABB

Herunterladen
ABB Raumtemperaturregler FanCoil mit Display

Raumtemperaturregler FanCoil mit Display

ABB Raumtemperaturregler FanCoil mit Display

ABB

Raumtemperaturregler FanCoil mit Display

ABB Raumtemperaturregler FanCoil mit Display

EMCS-Kompatibilität

.DWG .RFA .IFC

Steuereinheit für Zentralheizung

ABB

Herunterladen
ABB ClimaEco Raumtemperaturregler und FanCoil Bedienelement

ClimaEco Raumtemperaturregler und FanCoil Bedienelement

ABB ClimaEco Raumtemperaturregler und FanCoil Bedienelement

ABB

ClimaEco Raumtemperaturregler und FanCoil Bedienelement

ABB ClimaEco Raumtemperaturregler und FanCoil Bedienelement

EMCS-Kompatibilität

.DWG .RFA .IFC

Steuereinheit für Zentralheizung

ABB

Herunterladen
ABB ClimaEco Raumtemperaturregler Bedienelement

ClimaEco Raumtemperaturregler Bedienelement

ABB ClimaEco Raumtemperaturregler Bedienelement

ABB

ClimaEco Raumtemperaturregler Bedienelement

ABB ClimaEco Raumtemperaturregler Bedienelement

EMCS-Kompatibilität

.DWG .RFA .IFC

Steuereinheit für Zentralheizung

ABB

Herunterladen
Mitsubishi Electric PLFY-WP-VFM-E

PLFY-WP-VFM-E

4-way blow ceiling cassette indoor unit

Mitsubishi Electric

PLFY-WP-VFM-E

4-way blow ceiling cassette indoor unit

EMCS-Kompatibilität

.DWG .RFA .IFC

Klimaanlage

Mitsubishi Electric

Herunterladen
Hisense AVK

AVK

Console unit

Hisense

AVK

Console unit

EMCS-Kompatibilität

.DWG .RFA .IFC

Klimaanlage

Hisense

Herunterladen
Mitsubishi Electric MXZ 4(5)E

MXZ 4(5)E

Inverter heat pump Place directly in Revit and AutoCAD using the free [a href="https://store.mepcontent.com/Product/Details/49" target="_blank"]Mitsubishi Electric System Designer[/a] App

Mitsubishi Electric

MXZ 4(5)E

Inverter heat pump Place directly in Revit and AutoCAD using the free [a href="https://store.mepcontent.com/Product/Details/49" target="_blank"]Mitsubishi Electric System Designer[/a] App

EMCS-Kompatibilität

.DWG .RFA .IFC

Wärmepumpe

Mitsubishi Electric

Herunterladen
Mitsubishi Electric MXZ-D

MXZ-D

Inverter heat pump Place directly in Revit and AutoCAD using the free [a href="https://store.mepcontent.com/Product/Details/49" target="_blank"]Mitsubishi Electric System Designer[/a] App

Mitsubishi Electric

MXZ-D

Inverter heat pump Place directly in Revit and AutoCAD using the free [a href="https://store.mepcontent.com/Product/Details/49" target="_blank"]Mitsubishi Electric System Designer[/a] App

EMCS-Kompatibilität

.DWG .RFA .IFC

Wärmepumpe

Mitsubishi Electric

Herunterladen
Mitsubishi Electric MXZ-3(4)F

MXZ-3(4)F

Inverter heat pump Place directly in Revit and AutoCAD using the free [a href="https://store.mepcontent.com/Product/Details/49" target="_blank"]Mitsubishi Electric System Designer[/a] App

Mitsubishi Electric

MXZ-3(4)F

Inverter heat pump Place directly in Revit and AutoCAD using the free [a href="https://store.mepcontent.com/Product/Details/49" target="_blank"]Mitsubishi Electric System Designer[/a] App

EMCS-Kompatibilität

.DWG .RFA .IFC

Wärmepumpe

Mitsubishi Electric

Herunterladen
Mitsubishi Electric MXZ-2F

MXZ-2F

Inverter heat pump Place directly in Revit and AutoCAD using the free [a href="https://store.mepcontent.com/Product/Details/49" target="_blank"]Mitsubishi Electric System Designer[/a] App

Mitsubishi Electric

MXZ-2F

Inverter heat pump Place directly in Revit and AutoCAD using the free [a href="https://store.mepcontent.com/Product/Details/49" target="_blank"]Mitsubishi Electric System Designer[/a] App

EMCS-Kompatibilität

.DWG .RFA .IFC

Wärmepumpe

Mitsubishi Electric

Herunterladen
Mitsubishi Electric City Multi PEFY-WP-VMA

City Multi PEFY-WP-VMA

Ceiling concealed ducted indoor unit

Mitsubishi Electric

City Multi PEFY-WP-VMA

Ceiling concealed ducted indoor unit

EMCS-Kompatibilität

.DWG .RFA .IFC

Klimaanlage

Mitsubishi Electric

Herunterladen
Ecoforest AU12

AU12

AU12

Ecoforest

AU12

AU12

EMCS-Kompatibilität

.RFA

Steuereinheit für Zentralheizung

Ecoforest

Herunterladen
Ecoforest ecoGEOCompact C 5-22kW

ecoGEOCompact C 5-22kW

ecoGEOCompact C 5-22kW

Ecoforest

ecoGEOCompact C 5-22kW

ecoGEOCompact C 5-22kW

EMCS-Kompatibilität

.RFA

Wärmepumpe

Ecoforest

Herunterladen
Ecoforest ecoGEOCompact C 3-12kW

ecoGEOCompact C 3-12kW

ecoGEOCompact C 3-12kW

Ecoforest

ecoGEOCompact C 3-12kW

ecoGEOCompact C 3-12kW

EMCS-Kompatibilität

.RFA

Wärmepumpe

Ecoforest

Herunterladen
Ecoforest ecoGEOCompact C 1-9kW

ecoGEOCompact C 1-9kW

ecoGEOCompact C 1-9kW

Ecoforest

ecoGEOCompact C 1-9kW

ecoGEOCompact C 1-9kW

EMCS-Kompatibilität

.RFA

Wärmepumpe

Ecoforest

Herunterladen
Ecoforest ecoGEO HP 25-100kW

ecoGEO HP 25-100kW

ecoGEO HP 25-100kW

Ecoforest

ecoGEO HP 25-100kW

ecoGEO HP 25-100kW

EMCS-Kompatibilität

.RFA

Wärmepumpe

Ecoforest

Herunterladen
Ecoforest ecoGEO HP 15-70kW

ecoGEO HP 15-70kW

ecoGEO HP 15-70kW

Ecoforest

ecoGEO HP 15-70kW

ecoGEO HP 15-70kW

EMCS-Kompatibilität

.RFA

Wärmepumpe

Ecoforest

Herunterladen
Ecoforest ecoGEO HP 12-40kW

ecoGEO HP 12-40kW

ecoGEO HP 12-40kW

Ecoforest

ecoGEO HP 12-40kW

ecoGEO HP 12-40kW

EMCS-Kompatibilität

.RFA

Wärmepumpe

Ecoforest

Herunterladen
Ecoforest ecoGEO Basic B 5-22kW

ecoGEO Basic B 5-22kW

ecoGEO Basic B 5-22kW

Ecoforest

ecoGEO Basic B 5-22kW

ecoGEO Basic B 5-22kW

EMCS-Kompatibilität

.RFA

Wärmepumpe

Ecoforest

Herunterladen
Ecoforest ecoGEO Basic B 3-12kW

ecoGEO Basic B 3-12kW

ecoGEO Basic B 3-12kW

Ecoforest

ecoGEO Basic B 3-12kW

ecoGEO Basic B 3-12kW

EMCS-Kompatibilität

.RFA

Wärmepumpe

Ecoforest

Herunterladen
Ecoforest ecoGEO Basic B 1-9kW

ecoGEO Basic B 1-9kW

ecoGEO Basic 1-9kW

Ecoforest

ecoGEO Basic B 1-9kW

ecoGEO Basic 1-9kW

EMCS-Kompatibilität

.RFA

Wärmepumpe

Ecoforest

Herunterladen
Mitsubishi Electric PURY-EM R32 Heat Recovery (Model 2019)

PURY-EM R32 Heat Recovery (Model 2019)

Heat recovery Outdoor Unit Place directly in Revit and AutoCAD using the free [a href="https://store.mepcontent.com/Product/Details/49" target="_blank"]Mitsubishi Electric System Designer[/a] App

Mitsubishi Electric

PURY-EM R32 Heat Recovery (Model 2019)

Heat recovery Outdoor Unit Place directly in Revit and AutoCAD using the free [a href="https://store.mepcontent.com/Product/Details/49" target="_blank"]Mitsubishi Electric System Designer[/a] App

EMCS-Kompatibilität

.DWG .RFA .IFC

Wärmepumpe

Mitsubishi Electric

Herunterladen
Mitsubishi Electric PURY-M  R32  Heat Recovery (Model 2019)

PURY-M R32 Heat Recovery (Model 2019)

Heat recovery Outdoor Unit Place directly in Revit and AutoCAD using the free [a href="https://store.mepcontent.com/Product/Details/49" target="_blank"]Mitsubishi Electric System Designer[/a] App

Mitsubishi Electric

PURY-M R32 Heat Recovery (Model 2019)

Heat recovery Outdoor Unit Place directly in Revit and AutoCAD using the free [a href="https://store.mepcontent.com/Product/Details/49" target="_blank"]Mitsubishi Electric System Designer[/a] App

EMCS-Kompatibilität

.DWG .RFA .IFC

Wärmepumpe

Mitsubishi Electric

Herunterladen
IVAR Dirtstop®

Dirtstop®

Swivelling magnetic dirt separator with double filtering action, compact, with connection kit for the installation under the boiler. The double filtering action, guaranteed in any position thanks to the swivelling insert (Patent Pending), is performed by a neodymium magnet (magnetic induction B = 1,2 T (12.000 G)) and a mesh strainer (800 μm) made of AISI 304 stainless steel. The neodymium magnet is diametrically polarized and therefore it develops a homogeneous magnetic field which maximizes the capture of ferrous impurities. The mesh strainer retains all impurities. Impurities precipitate into the inclined settling chamber at the bottom of the dirt separator. The evacuation of impurities is possible without emptying the system and disassembling the dirt separator, thanks to the removable magnet and to the opening of a 360° swivelling shut-off ball valve. Body material: technopolymer IXEF®. Shut-off ball valve, swivelling fitting and plugs material: CW617N brass. Sealing elements material: Peroxide EPDM. Temperature: 0 ÷ 90 °C. Max pressure: 3 bars. Kv with swivelling insert in position A = 5,6 m3/h angle configuration; Kv with swivelling insert in position A1 = 6,2 m3/h straight configuration; Kv with swivelling insert in position B = 5,5 m3/h angle configuration; Kv with swivelling insert in position B1 =5,7 m3/h straight configuration. Compatible with water or glycol solutions max 50%. Connections: 3/4”M x 3/4"F.

IVAR

Dirtstop®

Swivelling magnetic dirt separator with double filtering action, compact, with connection kit for the installation under the boiler. The double filtering action, guaranteed in any position thanks to the swivelling insert (Patent Pending), is performed by a neodymium magnet (magnetic induction B = 1,2 T (12.000 G)) and a mesh strainer (800 μm) made of AISI 304 stainless steel. The neodymium magnet is diametrically polarized and therefore it develops a homogeneous magnetic field which maximizes the capture of ferrous impurities. The mesh strainer retains all impurities. Impurities precipitate into the inclined settling chamber at the bottom of the dirt separator. The evacuation of impurities is possible without emptying the system and disassembling the dirt separator, thanks to the removable magnet and to the opening of a 360° swivelling shut-off ball valve. Body material: technopolymer IXEF®. Shut-off ball valve, swivelling fitting and plugs material: CW617N brass. Sealing elements material: Peroxide EPDM. Temperature: 0 ÷ 90 °C. Max pressure: 3 bars. Kv with swivelling insert in position A = 5,6 m3/h angle configuration; Kv with swivelling insert in position A1 = 6,2 m3/h straight configuration; Kv with swivelling insert in position B = 5,5 m3/h angle configuration; Kv with swivelling insert in position B1 =5,7 m3/h straight configuration. Compatible with water or glycol solutions max 50%. Connections: 3/4”M x 3/4"F.

EMCS-Kompatibilität

.RFA

Steuereinheit für Zentralheizung

IVAR

Herunterladen
IVAR VS 2106 NH HARMONIA Thermostatic valve

VS 2106 NH HARMONIA Thermostatic valve

Angle thermostatic valve with flow rate pre-regulation and pressure dynamic balancing, HARMONIA-series, with male connection. Connection to iron pipe x Connection to radiator: EUROK x 1/2"M with or without O-ring. Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol-water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Differential pressure range: 0.1÷0.6 bar. Body material: nickel-plated CW617N brass. Gaskets and O-rings materials: Peroxide EPDM. Spring, washer and spindle material: Stainless steel. Protective cap: orange ABS.

IVAR

VS 2106 NH HARMONIA Thermostatic valve

Angle thermostatic valve with flow rate pre-regulation and pressure dynamic balancing, HARMONIA-series, with male connection. Connection to iron pipe x Connection to radiator: EUROK x 1/2"M with or without O-ring. Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol-water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Differential pressure range: 0.1÷0.6 bar. Body material: nickel-plated CW617N brass. Gaskets and O-rings materials: Peroxide EPDM. Spring, washer and spindle material: Stainless steel. Protective cap: orange ABS.

EMCS-Kompatibilität

.RFA

Ventil für Heizung und Kühlung

IVAR

Herunterladen
IVAR VS 2102 NH HARMONIA Thermostatic valve

VS 2102 NH HARMONIA Thermostatic valve

Angle thermostatic valve with flow rate pre-regulation and pressure dynamic balancing, HARMONIA-series, with female connection. Connection to iron pipe x Connection to radiator: 3/8"F x 3/8"M with or without O-ring, 1/2"F x 1/2"M with or without O-ring. Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol-water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Differential pressure range: 0.1÷0.6 bar. Body material: nickel-plated CW617N brass. Gaskets and O-rings materials: Peroxide EPDM. Spring, washer and spindle material: Stainless steel. Protective cap: orange ABS.

IVAR

VS 2102 NH HARMONIA Thermostatic valve

Angle thermostatic valve with flow rate pre-regulation and pressure dynamic balancing, HARMONIA-series, with female connection. Connection to iron pipe x Connection to radiator: 3/8"F x 3/8"M with or without O-ring, 1/2"F x 1/2"M with or without O-ring. Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol-water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Differential pressure range: 0.1÷0.6 bar. Body material: nickel-plated CW617N brass. Gaskets and O-rings materials: Peroxide EPDM. Spring, washer and spindle material: Stainless steel. Protective cap: orange ABS.

EMCS-Kompatibilität

.RFA

Ventil für Heizung und Kühlung

IVAR

Herunterladen
IVAR VD 2105 NH HARMONIA Thermostatic valve

VD 2105 NH HARMONIA Thermostatic valve

Straight thermostatic valve with flow rate pre-regulation and pressure dynamic balancing, HARMONIA-series, with male connection. Connection to iron pipe x Connection to radiator: EUROK x 1/2"M with or without O-ring. Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol-water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Differential pressure range: 0.1÷0.6 bar. Body material: nickel-plated CW617N brass. Gaskets and O-rings materials: Peroxide EPDM. Spring, washer and spindle material: Stainless steel. Protective cap: orange ABS.

IVAR

VD 2105 NH HARMONIA Thermostatic valve

Straight thermostatic valve with flow rate pre-regulation and pressure dynamic balancing, HARMONIA-series, with male connection. Connection to iron pipe x Connection to radiator: EUROK x 1/2"M with or without O-ring. Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol-water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Differential pressure range: 0.1÷0.6 bar. Body material: nickel-plated CW617N brass. Gaskets and O-rings materials: Peroxide EPDM. Spring, washer and spindle material: Stainless steel. Protective cap: orange ABS.

EMCS-Kompatibilität

.RFA

Ventil für Heizung und Kühlung

IVAR

Herunterladen
IVAR VD 2101 NH HARMONIA Thermostatic valve

VD 2101 NH HARMONIA Thermostatic valve

Straight thermostatic valve with flow rate pre-regulation and pressure dynamic balancing, HARMONIA-series, with female connection. Connection to iron pipe x Connection to radiator: 3/8"F x 3/8"M with or without O-ring, 1/2"F x 1/2"M with or without O-ring. Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol-water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Differential pressure range: 0.1÷0.6 bar. Body material: nickel-plated CW617N brass. Gaskets and O-rings materials: Peroxide EPDM. Spring, washer and spindle material: Stainless steel. Protective cap: orange ABS.

IVAR

VD 2101 NH HARMONIA Thermostatic valve

Straight thermostatic valve with flow rate pre-regulation and pressure dynamic balancing, HARMONIA-series, with female connection. Connection to iron pipe x Connection to radiator: 3/8"F x 3/8"M with or without O-ring, 1/2"F x 1/2"M with or without O-ring. Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol-water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Differential pressure range: 0.1÷0.6 bar. Body material: nickel-plated CW617N brass. Gaskets and O-rings materials: Peroxide EPDM. Spring, washer and spindle material: Stainless steel. Protective cap: orange ABS.

EMCS-Kompatibilität

.RFA

Ventil für Heizung und Kühlung

IVAR

Herunterladen
IVAR VCS 2166 NH SX – VCD 2166 NH DX HARMONIA Thermostatic valve

VCS 2166 NH SX – VCD 2166 NH DX HARMONIA Thermostatic valve

Co-axial left/right thermostatic valve with flow rate pre-regulation and pressure dynamic balancing, HARMONIA-series, with male connection. Connection to iron pipe x Connection to radiator: EUROK x 1/2"M with or without O-ring. Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol-water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Differential pressure range: 0.1÷0.6 bar. Body material: nickel-plated CW617N brass. Gaskets and O-rings materials: Peroxide EPDM. Spring, washer and spindle material: Stainless steel. Protective cap: orange ABS.

IVAR

VCS 2166 NH SX – VCD 2166 NH DX HARMONIA Thermostatic valve

Co-axial left/right thermostatic valve with flow rate pre-regulation and pressure dynamic balancing, HARMONIA-series, with male connection. Connection to iron pipe x Connection to radiator: EUROK x 1/2"M with or without O-ring. Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol-water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Differential pressure range: 0.1÷0.6 bar. Body material: nickel-plated CW617N brass. Gaskets and O-rings materials: Peroxide EPDM. Spring, washer and spindle material: Stainless steel. Protective cap: orange ABS.

EMCS-Kompatibilität

.RFA

Ventil für Heizung und Kühlung

IVAR

Herunterladen
IVAR VCS 2162 NH SX – VCD 2162 NH DX HARMONIA Thermostatic valve

VCS 2162 NH SX – VCD 2162 NH DX HARMONIA Thermostatic valve

Co-axial left/right thermostatic valve with flow rate pre-regulation and pressure dynamic balancing, HARMONIA-series, with female connection. Connection to iron pipe x Connection to radiator: 3/8"F x 3/8"M with or without O-ring, 1/2"F x 1/2"M with or without O-ring. Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol-water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Differential pressure range: 0.1÷0.6 bar. Body material: nickel-plated CW617N brass. Gaskets and O-rings materials: Peroxide EPDM. Spring, washer and spindle material: Stainless steel. Protective cap: orange ABS.

IVAR

VCS 2162 NH SX – VCD 2162 NH DX HARMONIA Thermostatic valve

Co-axial left/right thermostatic valve with flow rate pre-regulation and pressure dynamic balancing, HARMONIA-series, with female connection. Connection to iron pipe x Connection to radiator: 3/8"F x 3/8"M with or without O-ring, 1/2"F x 1/2"M with or without O-ring. Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol-water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Differential pressure range: 0.1÷0.6 bar. Body material: nickel-plated CW617N brass. Gaskets and O-rings materials: Peroxide EPDM. Spring, washer and spindle material: Stainless steel. Protective cap: orange ABS.

EMCS-Kompatibilität

.RFA

Ventil für Heizung und Kühlung

IVAR

Herunterladen
IVAR VCR 2136 NH HARMONIA Thermostatic valve

VCR 2136 NH HARMONIA Thermostatic valve

Reverse thermostatic valve with flow rate pre-regulation and pressure dynamic balancing, HARMONIA-series, with male connection. Connection to iron pipe x Connection to radiator: EUROK x 1/2"M with or without O-ring. Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol-water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Differential pressure range: 0.1÷0.6 bar. Body material: nickel-plated CW617N brass. Gaskets and O-rings materials: Peroxide EPDM. Spring, washer and spindle material: Stainless steel. Protective cap: orange ABS.

IVAR

VCR 2136 NH HARMONIA Thermostatic valve

Reverse thermostatic valve with flow rate pre-regulation and pressure dynamic balancing, HARMONIA-series, with male connection. Connection to iron pipe x Connection to radiator: EUROK x 1/2"M with or without O-ring. Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol-water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Differential pressure range: 0.1÷0.6 bar. Body material: nickel-plated CW617N brass. Gaskets and O-rings materials: Peroxide EPDM. Spring, washer and spindle material: Stainless steel. Protective cap: orange ABS.

EMCS-Kompatibilität

.RFA

Ventil für Heizung und Kühlung

IVAR

Herunterladen
IVAR VCR 2132 NH HARMONIA Thermostatic valve

VCR 2132 NH HARMONIA Thermostatic valve

Reverse thermostatic valve with flow rate pre-regulation and pressure dynamic balancing, HARMONIA-series, with female connection. Connection to iron pipe x Connection to radiator: G 3/8"F x G 3/8"M with or without O-ring, G 1/2"F x G 1/2"M with or without O-ring. Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol-water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Differential pressure range: 0.1÷0.6 bar. Body material: nickel-plated CW617N brass. Gaskets and O-rings materials: Peroxide EPDM. Spring, washer and spindle material: Stainless steel. Protective cap: orange ABS.

IVAR

VCR 2132 NH HARMONIA Thermostatic valve

Reverse thermostatic valve with flow rate pre-regulation and pressure dynamic balancing, HARMONIA-series, with female connection. Connection to iron pipe x Connection to radiator: G 3/8"F x G 3/8"M with or without O-ring, G 1/2"F x G 1/2"M with or without O-ring. Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol-water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Differential pressure range: 0.1÷0.6 bar. Body material: nickel-plated CW617N brass. Gaskets and O-rings materials: Peroxide EPDM. Spring, washer and spindle material: Stainless steel. Protective cap: orange ABS.

EMCS-Kompatibilität

.RFA

Ventil für Heizung und Kühlung

IVAR

Herunterladen
IVAR VS 2102 Thermostatic valve

VS 2102 Thermostatic valve

Angle thermostatic valve with female connection. Connection to iron pipe x Connection to radiator: G 3/8"F x G 3/8"M with or without O-ring (with white protective cap or manual head), G 1/2"F x G 1/2"M with or without O-ring (with white protective cap or manual head), G 3/4"F x G 3/4"M with or without O-ring (with white protective cap or manual head), G 1"F x G 1"M with or without O-ring (with white protective cap), G 1"1/4F x G 1"1/4M with or without O-ring (with white protective cap). Flow rate pre-regulation only available for 3/8", 1/2" and 3/4" sizes: N-series (black protective cap or white manual head) or F-series (red protective cap or white manual head). Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol-water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Max differential pressure: 1 bar. Max differential pressure with thermostatic head installed: 0.25 bar. Body material: nickel-plated CW617N brass. Gaskets and O-rings materials: peroxide EPDM. Spring, washer and spindle material: stainless steel. Protective cap and manual head material: ABS.

IVAR

VS 2102 Thermostatic valve

Angle thermostatic valve with female connection. Connection to iron pipe x Connection to radiator: G 3/8"F x G 3/8"M with or without O-ring (with white protective cap or manual head), G 1/2"F x G 1/2"M with or without O-ring (with white protective cap or manual head), G 3/4"F x G 3/4"M with or without O-ring (with white protective cap or manual head), G 1"F x G 1"M with or without O-ring (with white protective cap), G 1"1/4F x G 1"1/4M with or without O-ring (with white protective cap). Flow rate pre-regulation only available for 3/8", 1/2" and 3/4" sizes: N-series (black protective cap or white manual head) or F-series (red protective cap or white manual head). Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol-water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Max differential pressure: 1 bar. Max differential pressure with thermostatic head installed: 0.25 bar. Body material: nickel-plated CW617N brass. Gaskets and O-rings materials: peroxide EPDM. Spring, washer and spindle material: stainless steel. Protective cap and manual head material: ABS.

EMCS-Kompatibilität

.RFA

Steuereinheit für Zentralheizung

IVAR

Herunterladen
IVAR VD 2101 Thermostatic valve

VD 2101 Thermostatic valve

Straight thermostatic valve with female connection. Connection to iron pipe x Connection to radiator: G 3/8"F x G 3/8"M with or without O-ring (with white protective cap or manual head), G 1/2"F x G 1/2"M with or without O-ring (with white protective cap or manual head), G 3/4"F x G 3/4"M with or without O-ring (with white protective cap or manual head), G 1"F x G 1"M with or without O-ring (with white protective cap), G 1"1/4F x G 1"1/4M with or without O-ring (with white protective cap). Flow rate pre-regulation only available for 3/8", 1/2" and 3/4" sizes: N-series (black protective cap or white manual head) or F-series (red protective cap or white manual head). Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol-water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Max differential pressure: 1 bar. Max differential pressure with thermostatic head installed: 0.25 bar. Body material: nickel-plated CW617N brass. Gaskets and O-rings materials: peroxide EPDM. Spring, washer and spindle material: stainless steel. Protective cap and manual head material: ABS.

IVAR

VD 2101 Thermostatic valve

Straight thermostatic valve with female connection. Connection to iron pipe x Connection to radiator: G 3/8"F x G 3/8"M with or without O-ring (with white protective cap or manual head), G 1/2"F x G 1/2"M with or without O-ring (with white protective cap or manual head), G 3/4"F x G 3/4"M with or without O-ring (with white protective cap or manual head), G 1"F x G 1"M with or without O-ring (with white protective cap), G 1"1/4F x G 1"1/4M with or without O-ring (with white protective cap). Flow rate pre-regulation only available for 3/8", 1/2" and 3/4" sizes: N-series (black protective cap or white manual head) or F-series (red protective cap or white manual head). Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol-water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Max differential pressure: 1 bar. Max differential pressure with thermostatic head installed: 0.25 bar. Body material: nickel-plated CW617N brass. Gaskets and O-rings materials: peroxide EPDM. Spring, washer and spindle material: stainless steel. Protective cap and manual head material: ABS.

EMCS-Kompatibilität

.RFA

Steuereinheit für Zentralheizung

IVAR

Herunterladen
Mitsubishi Electric CMB-WM R32 (Model 2019)

CMB-WM R32 (Model 2019)

Master / Slave HBC controllers Place directly in Revit and AutoCAD using the free [a href="https://store.mepcontent.com/Product/Details/49" target="_blank"]Mitsubishi Electric System Designer[/a] App

Mitsubishi Electric

CMB-WM R32 (Model 2019)

Master / Slave HBC controllers Place directly in Revit and AutoCAD using the free [a href="https://store.mepcontent.com/Product/Details/49" target="_blank"]Mitsubishi Electric System Designer[/a] App

EMCS-Kompatibilität

.DWG .RFA .IFC

Wärmepumpe

Mitsubishi Electric

Herunterladen
Reflex Variomat VG

Variomat VG

Expansion pump dispenser primary vessel

Reflex

Variomat VG

Expansion pump dispenser primary vessel

EMCS-Kompatibilität

.RFA

Ausdehnungsgefäß

Reflex

Herunterladen
Reflex Variomat VF

Variomat VF

Pump dispenser expansion auxiliary vessel

Reflex

Variomat VF

Pump dispenser expansion auxiliary vessel

EMCS-Kompatibilität

.RFA

Ausdehnungsgefäß

Reflex

Herunterladen
Reflex Reflexomat RG

Reflexomat RG

Compressor expansion automat primary vessel

Reflex

Reflexomat RG

Compressor expansion automat primary vessel

EMCS-Kompatibilität

.RFA

Ausdehnungsgefäß

Reflex

Herunterladen
Reflex Reflexomat RF

Reflexomat RF

Compressor expansion automat auxiliary vessel

Reflex

Reflexomat RF

Compressor expansion automat auxiliary vessel

EMCS-Kompatibilität

.RFA

Ausdehnungsgefäß

Reflex

Herunterladen
Reflex Reflex S

Reflex S

Expansion vessel

Reflex

Reflex S

Expansion vessel

EMCS-Kompatibilität

.RFA

Ausdehnungsgefäß

Reflex

Herunterladen
Reflex Reflex N

Reflex N

Expansion vessel

Reflex

Reflex N

Expansion vessel

EMCS-Kompatibilität

.RFA

Ausdehnungsgefäß

Reflex

Herunterladen
Reflex Reflex V

Reflex V

Intermediate vessel

Reflex

Reflex V

Intermediate vessel

EMCS-Kompatibilität

.RFA

Ausdehnungsgefäß

Reflex

Herunterladen
Reflex Reflex G

Reflex G

Expansion vessel

Reflex

Reflex G

Expansion vessel

EMCS-Kompatibilität

.RFA

Ausdehnungsgefäß

Reflex

Herunterladen
Reflex Refix DT

Refix DT

Expansion vessel

Reflex

Refix DT

Expansion vessel

EMCS-Kompatibilität

.RFA

Ausdehnungsgefäß

Reflex

Herunterladen
Reflex Refix DE

Refix DE

Expansion vessel

Reflex

Refix DE

Expansion vessel

EMCS-Kompatibilität

.RFA

Ausdehnungsgefäß

Reflex

Herunterladen
Reflex Refix DC

Refix DC

Expansion vessel

Reflex

Refix DC

Expansion vessel

EMCS-Kompatibilität

.RFA

Ausdehnungsgefäß

Reflex

Herunterladen
Reflex Reflex V

Reflex V

Intermediate vessel

Reflex

Reflex V

Intermediate vessel

EMCS-Kompatibilität

.RFA

Ausdehnungsgefäß

Reflex

Herunterladen
Reflex Reflex S

Reflex S

Expansion vessel

Reflex

Reflex S

Expansion vessel

EMCS-Kompatibilität

.RFA

Ausdehnungsgefäß

Reflex

Herunterladen
Reflex Reflex N

Reflex N

Expansion vessel

Reflex

Reflex N

Expansion vessel

EMCS-Kompatibilität

.RFA

Ausdehnungsgefäß

Reflex

Herunterladen
Reflex Refix DE

Refix DE

Expansion vessel

Reflex

Refix DE

Expansion vessel

EMCS-Kompatibilität

.RFA

Ausdehnungsgefäß

Reflex

Herunterladen
Reflex Refix DD

Refix DD

Expansion vessel

Reflex

Refix DD

Expansion vessel

EMCS-Kompatibilität

.RFA

Ausdehnungsgefäß

Reflex

Herunterladen
Reflex Refix DC 25

Refix DC 25

Expansion vessel

Reflex

Refix DC 25

Expansion vessel

EMCS-Kompatibilität

.RFA

Ausdehnungsgefäß

Reflex

Herunterladen
Reflex Servitec 95

Servitec 95

Self-optimizing vacuum spray deaeration/make-up unit

Reflex

Servitec 95

Self-optimizing vacuum spray deaeration/make-up unit

EMCS-Kompatibilität

.RFA .IFC

Steuereinheit für Zentralheizung

Reflex

Herunterladen
Reflex Servitec 75

Servitec 75

Self-optimizing vacuum spray deaeration/make-up unit

Reflex

Servitec 75

Self-optimizing vacuum spray deaeration/make-up unit

EMCS-Kompatibilität

.RFA .IFC

Steuereinheit für Zentralheizung

Reflex

Herunterladen
Reflex Servitec 60

Servitec 60

Self-optimizing vacuum spray deaeration/make-up unit

Reflex

Servitec 60

Self-optimizing vacuum spray deaeration/make-up unit

EMCS-Kompatibilität

.RFA .IFC

Steuereinheit für Zentralheizung

Reflex

Herunterladen
Reflex Servitec 35

Servitec 35

Self-optimizing vacuum spray deaeration/make-up unit

Reflex

Servitec 35

Self-optimizing vacuum spray deaeration/make-up unit

EMCS-Kompatibilität

.RFA .IFC

Steuereinheit für Zentralheizung

Reflex

Herunterladen
Remeha Tzerra Ace

Tzerra Ace

Gas Boiler CW3 concentric

Remeha

Tzerra Ace

Gas Boiler CW3 concentric

EMCS-Kompatibilität

.DWG .RFA .IFC

Kessel

Remeha

Herunterladen
Mitsubishi Electric Ecodan SUHZ-SW45VA

Ecodan SUHZ-SW45VA

Split-type air source heat pump Place directly in Revit and AutoCAD using the free [a href="https://store.mepcontent.com/Product/Details/49" target="_blank"]Mitsubishi Electric System Designer[/a] App

Mitsubishi Electric

Ecodan SUHZ-SW45VA

Split-type air source heat pump Place directly in Revit and AutoCAD using the free [a href="https://store.mepcontent.com/Product/Details/49" target="_blank"]Mitsubishi Electric System Designer[/a] App

EMCS-Kompatibilität

.DWG .RFA .IFC

Wärmepumpe

Mitsubishi Electric

Herunterladen
Mitsubishi Electric Ecodan PUMY-P200YKM2

Ecodan PUMY-P200YKM2

Heat pump outdoor unit Place directly in Revit and AutoCAD using the free [a href="https://store.mepcontent.com/Product/Details/49" target="_blank"]Mitsubishi Electric System Designer[/a] App

Mitsubishi Electric

Ecodan PUMY-P200YKM2

Heat pump outdoor unit Place directly in Revit and AutoCAD using the free [a href="https://store.mepcontent.com/Product/Details/49" target="_blank"]Mitsubishi Electric System Designer[/a] App

EMCS-Kompatibilität

.DWG .RFA .IFC

Wärmepumpe

Mitsubishi Electric

Herunterladen
Mitsubishi Electric Ecodan PUMY-P112-140VKM4

Ecodan PUMY-P112-140VKM4

Monobloc standalone air source heat pump Place directly in Revit and AutoCAD using the free [a href="https://store.mepcontent.com/Product/Details/49" target="_blank"]Mitsubishi Electric System Designer[/a] App

Mitsubishi Electric

Ecodan PUMY-P112-140VKM4

Monobloc standalone air source heat pump Place directly in Revit and AutoCAD using the free [a href="https://store.mepcontent.com/Product/Details/49" target="_blank"]Mitsubishi Electric System Designer[/a] App

EMCS-Kompatibilität

.DWG .RFA .IFC

Wärmepumpe

Mitsubishi Electric

Herunterladen
Mitsubishi Electric Ecodan PUMY-P112-140YKM(E)4

Ecodan PUMY-P112-140YKM(E)4

Monobloc standalone air source heat pump Place directly in Revit and AutoCAD using the free [a href="https://store.mepcontent.com/Product/Details/49" target="_blank"]Mitsubishi Electric System Designer[/a] App

Mitsubishi Electric

Ecodan PUMY-P112-140YKM(E)4

Monobloc standalone air source heat pump Place directly in Revit and AutoCAD using the free [a href="https://store.mepcontent.com/Product/Details/49" target="_blank"]Mitsubishi Electric System Designer[/a] App

EMCS-Kompatibilität

.DWG .RFA .IFC

Wärmepumpe

Mitsubishi Electric

Herunterladen
Mitsubishi Electric Ecodan PUHZ-W85-112YAA

Ecodan PUHZ-W85-112YAA

Monobloc standalone air source heat pump Place directly in Revit and AutoCAD using the free [a href="https://store.mepcontent.com/Product/Details/49" target="_blank"]Mitsubishi Electric System Designer[/a] App

Mitsubishi Electric

Ecodan PUHZ-W85-112YAA

Monobloc standalone air source heat pump Place directly in Revit and AutoCAD using the free [a href="https://store.mepcontent.com/Product/Details/49" target="_blank"]Mitsubishi Electric System Designer[/a] App

EMCS-Kompatibilität

.DWG .RFA .IFC

Wärmepumpe

Mitsubishi Electric

Herunterladen
Mitsubishi Electric Ecodan PUHZ-W85-112VAA

Ecodan PUHZ-W85-112VAA

Monobloc standalone air source heat pump Place directly in Revit and AutoCAD using the free [a href="https://store.mepcontent.com/Product/Details/49" target="_blank"]Mitsubishi Electric System Designer[/a] App

Mitsubishi Electric

Ecodan PUHZ-W85-112VAA

Monobloc standalone air source heat pump Place directly in Revit and AutoCAD using the free [a href="https://store.mepcontent.com/Product/Details/49" target="_blank"]Mitsubishi Electric System Designer[/a] App

EMCS-Kompatibilität

.DWG .RFA .IFC

Wärmepumpe

Mitsubishi Electric

Herunterladen
Mitsubishi Electric Ecodan PUHZ-SW100VHA

Ecodan PUHZ-SW100VHA

Ecodan split air source heat pump Place directly in Revit and AutoCAD using the free [a href="https://store.mepcontent.com/Product/Details/49" target="_blank"]Mitsubishi Electric System Designer[/a] App

Mitsubishi Electric

Ecodan PUHZ-SW100VHA

Ecodan split air source heat pump Place directly in Revit and AutoCAD using the free [a href="https://store.mepcontent.com/Product/Details/49" target="_blank"]Mitsubishi Electric System Designer[/a] App

EMCS-Kompatibilität

.DWG .RFA .IFC

Wärmepumpe

Mitsubishi Electric

Herunterladen
Mitsubishi Electric Ecodan PUHZ-SW100-120YHA

Ecodan PUHZ-SW100-120YHA

Ecodan split air source heat pump Place directly in Revit and AutoCAD using the free [a href="https://store.mepcontent.com/Product/Details/49" target="_blank"]Mitsubishi Electric System Designer[/a] App

Mitsubishi Electric

Ecodan PUHZ-SW100-120YHA

Ecodan split air source heat pump Place directly in Revit and AutoCAD using the free [a href="https://store.mepcontent.com/Product/Details/49" target="_blank"]Mitsubishi Electric System Designer[/a] App

EMCS-Kompatibilität

.DWG .RFA .IFC

Wärmepumpe

Mitsubishi Electric

Herunterladen
Mitsubishi Electric Ecodan PUHZ-SW75-100YAA

Ecodan PUHZ-SW75-100YAA

Monobloc standalone air source heat pump Place directly in Revit and AutoCAD using the free [a href="https://store.mepcontent.com/Product/Details/49" target="_blank"]Mitsubishi Electric System Designer[/a] App

Mitsubishi Electric

Ecodan PUHZ-SW75-100YAA

Monobloc standalone air source heat pump Place directly in Revit and AutoCAD using the free [a href="https://store.mepcontent.com/Product/Details/49" target="_blank"]Mitsubishi Electric System Designer[/a] App

EMCS-Kompatibilität

.DWG .RFA .IFC

Wärmepumpe

Mitsubishi Electric

Herunterladen
Mitsubishi Electric Ecodan PUHZ-SW75-100VAA

Ecodan PUHZ-SW75-100VAA

Ecodan split air source heat pump Place directly in Revit and AutoCAD using the free [a href="https://store.mepcontent.com/Product/Details/49" target="_blank"]Mitsubishi Electric System Designer[/a] App

Mitsubishi Electric

Ecodan PUHZ-SW75-100VAA

Ecodan split air source heat pump Place directly in Revit and AutoCAD using the free [a href="https://store.mepcontent.com/Product/Details/49" target="_blank"]Mitsubishi Electric System Designer[/a] App

EMCS-Kompatibilität

.DWG .RFA .IFC

Wärmepumpe

Mitsubishi Electric

Herunterladen
Mitsubishi Electric Ecodan PUHZ-SHW80VHA_

Ecodan PUHZ-SHW80VHA_

Ecodan split air source heat pump Place directly in Revit and AutoCAD using the free [a href="https://store.mepcontent.com/Product/Details/49" target="_blank"]Mitsubishi Electric System Designer[/a] App

Mitsubishi Electric

Ecodan PUHZ-SHW80VHA_

Ecodan split air source heat pump Place directly in Revit and AutoCAD using the free [a href="https://store.mepcontent.com/Product/Details/49" target="_blank"]Mitsubishi Electric System Designer[/a] App

EMCS-Kompatibilität

.DWG .RFA .IFC

Wärmepumpe

Mitsubishi Electric

Herunterladen
Mitsubishi Electric Ecodan PUHZ-SHW80-112YAA

Ecodan PUHZ-SHW80-112YAA

Monobloc standalone air source heat pump Place directly in Revit and AutoCAD using the free [a href="https://store.mepcontent.com/Product/Details/49" target="_blank"]Mitsubishi Electric System Designer[/a] App

Mitsubishi Electric

Ecodan PUHZ-SHW80-112YAA

Monobloc standalone air source heat pump Place directly in Revit and AutoCAD using the free [a href="https://store.mepcontent.com/Product/Details/49" target="_blank"]Mitsubishi Electric System Designer[/a] App

EMCS-Kompatibilität

.DWG .RFA .IFC

Wärmepumpe

Mitsubishi Electric

Herunterladen
Mitsubishi Electric Ecodan PUHZ-SHW80-112VAA

Ecodan PUHZ-SHW80-112VAA

Monobloc standalone air source heat pump Place directly in Revit and AutoCAD using the free [a href="https://store.mepcontent.com/Product/Details/49" target="_blank"]Mitsubishi Electric System Designer[/a] App

Mitsubishi Electric

Ecodan PUHZ-SHW80-112VAA

Monobloc standalone air source heat pump Place directly in Revit and AutoCAD using the free [a href="https://store.mepcontent.com/Product/Details/49" target="_blank"]Mitsubishi Electric System Designer[/a] App

EMCS-Kompatibilität

.DWG .RFA .IFC

Wärmepumpe

Mitsubishi Electric

Herunterladen
Mitsubishi Electric Ecodan PUHZ-HW112YHA2

Ecodan PUHZ-HW112YHA2

Monobloc standalone air source heat pump Place directly in Revit and AutoCAD using the free [a href="https://store.mepcontent.com/Product/Details/49" target="_blank"]Mitsubishi Electric System Designer[/a] App

Mitsubishi Electric

Ecodan PUHZ-HW112YHA2

Monobloc standalone air source heat pump Place directly in Revit and AutoCAD using the free [a href="https://store.mepcontent.com/Product/Details/49" target="_blank"]Mitsubishi Electric System Designer[/a] App

EMCS-Kompatibilität

.DWG .RFA .IFC

Wärmepumpe

Mitsubishi Electric

Herunterladen
Mitsubishi Electric Ecodan PUHZ-FRP71VHA2

Ecodan PUHZ-FRP71VHA2

Split type air source heat pump Place directly in Revit and AutoCAD using the free [a href="https://store.mepcontent.com/Product/Details/49" target="_blank"]Mitsubishi Electric System Designer[/a] App

Mitsubishi Electric

Ecodan PUHZ-FRP71VHA2

Split type air source heat pump Place directly in Revit and AutoCAD using the free [a href="https://store.mepcontent.com/Product/Details/49" target="_blank"]Mitsubishi Electric System Designer[/a] App

EMCS-Kompatibilität

.DWG .RFA .IFC

Wärmepumpe

Mitsubishi Electric

Herunterladen
Mitsubishi Electric Ecodan PAC-MK52-53BC

Ecodan PAC-MK52-53BC

BC controllers Place directly in Revit and AutoCAD using the free [a href="https://store.mepcontent.com/Product/Details/49" target="_blank"]Mitsubishi Electric System Designer[/a] App

Mitsubishi Electric

Ecodan PAC-MK52-53BC

BC controllers Place directly in Revit and AutoCAD using the free [a href="https://store.mepcontent.com/Product/Details/49" target="_blank"]Mitsubishi Electric System Designer[/a] App

EMCS-Kompatibilität

.DWG .RFA .IFC

Verteiler für Zentralheizung

Mitsubishi Electric

Herunterladen
Mitsubishi Electric Ecodan PAC-MK32-33BC

Ecodan PAC-MK32-33BC

BC controllers Place directly in Revit and AutoCAD using the free [a href="https://store.mepcontent.com/Product/Details/49" target="_blank"]Mitsubishi Electric System Designer[/a] App

Mitsubishi Electric

Ecodan PAC-MK32-33BC

BC controllers Place directly in Revit and AutoCAD using the free [a href="https://store.mepcontent.com/Product/Details/49" target="_blank"]Mitsubishi Electric System Designer[/a] App

EMCS-Kompatibilität

.DWG .RFA .IFC

Verteiler für Zentralheizung

Mitsubishi Electric

Herunterladen
IVAR METERING MODULES_EQUIMETER

METERING MODULES_EQUIMETER

Equimeter metering module with unit for heat only. Heat metering unit: Qn =1,5 m3/h (for modules with kv = 2,25); Qn =2,5 m3/h (for modules with kv = 2,75). MATERIALS Heat metering monoblock: CB753S brass. Shut-off valves: CW617N brass. Sealing elements: Peroxide EPDM. Cabinet: white painted galvanized steel sheet. Support: galvanized steel sheet. CONDITIONS OF USE Maximum static operating pressure: 10 bar. Maximum fluid temperature: 90 °C. CONNECTIONS G 3/4"M

IVAR

METERING MODULES_EQUIMETER

Equimeter metering module with unit for heat only. Heat metering unit: Qn =1,5 m3/h (for modules with kv = 2,25); Qn =2,5 m3/h (for modules with kv = 2,75). MATERIALS Heat metering monoblock: CB753S brass. Shut-off valves: CW617N brass. Sealing elements: Peroxide EPDM. Cabinet: white painted galvanized steel sheet. Support: galvanized steel sheet. CONDITIONS OF USE Maximum static operating pressure: 10 bar. Maximum fluid temperature: 90 °C. CONNECTIONS G 3/4"M

EMCS-Kompatibilität

.RFA

Steuereinheit für Zentralheizung

IVAR

Herunterladen
IVAR BRASS-ROD MANIFOLDS_CI552N

BRASS-ROD MANIFOLDS_CI552N

Flow manifold with micrometric dually adjusted lockshields and EUROK connections. Manifolds can be used as supply manifolds only. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 120°C.Maximum operating pressure: 10 bar.  Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 1 to 13 ways.

IVAR

BRASS-ROD MANIFOLDS_CI552N

Flow manifold with micrometric dually adjusted lockshields and EUROK connections. Manifolds can be used as supply manifolds only. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 120°C.Maximum operating pressure: 10 bar.  Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 1 to 13 ways.

EMCS-Kompatibilität

.RFA

Verteiler für Zentralheizung

IVAR

Herunterladen
IVAR BRASS-ROD MANIFOLDS_CI554MN

BRASS-ROD MANIFOLDS_CI554MN

Return manifold with manually operated isolation valves and EUROK connections. Manifolds can be used as return manifolds only. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 120°C. Maximum operating pressure: 10 bar.  Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 1 to 13 ways.

IVAR

BRASS-ROD MANIFOLDS_CI554MN

Return manifold with manually operated isolation valves and EUROK connections. Manifolds can be used as return manifolds only. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 120°C. Maximum operating pressure: 10 bar.  Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 1 to 13 ways.

EMCS-Kompatibilität

.RFA

Verteiler für Zentralheizung

IVAR

Herunterladen
IVAR BRASS-ROD MANIFOLDS_CI562MN

BRASS-ROD MANIFOLDS_CI562MN

Kit made of flow manifold with double micrometric adjustment lockshields, return manifold with manually operated isolation valves, brackets and EUROK connections. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 120°C. Maximum operating pressure: 10 bar. Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 2 to 13 ways.

IVAR

BRASS-ROD MANIFOLDS_CI562MN

Kit made of flow manifold with double micrometric adjustment lockshields, return manifold with manually operated isolation valves, brackets and EUROK connections. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 120°C. Maximum operating pressure: 10 bar. Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 2 to 13 ways.

EMCS-Kompatibilität

.RFA

Verteiler für Zentralheizung

IVAR

Herunterladen
IVAR BRASS-ROD MANIFOLDS_CI595MN

BRASS-ROD MANIFOLDS_CI595MN

Kit made of flow manifold with flow meter/adjusters FLUXER (0-5 l/min), return manifold with manually operated isolation valves, brackets and EUROK connections. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 90°C. Maximum operating pressure: 10 bar. Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 2 to 13 ways.

IVAR

BRASS-ROD MANIFOLDS_CI595MN

Kit made of flow manifold with flow meter/adjusters FLUXER (0-5 l/min), return manifold with manually operated isolation valves, brackets and EUROK connections. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 90°C. Maximum operating pressure: 10 bar. Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 2 to 13 ways.

EMCS-Kompatibilität

.RFA

Verteiler für Zentralheizung

IVAR

Herunterladen