79 BIM collections found from 17 manufacturer(s) in Francia
IVAR IS-BOX

IS-BOX

IS-BOX is a box with a pair of pre-installed 3+1 and 4+1 outlet sanitary manifolds, suitable for wall recessing even in bathrooms covered with tiles or valuable materials. The reduced size allows it to be installed in brick or plasterboard walls with a minimum thickness of 60 mm. The manifolds are compatible with drinking water and the inlets can be shut off by screw sealing valves and replaceable headworks. Available in two colours (white and chrome), also in the completely inspectable version.

IVAR

IS-BOX

IS-BOX is a box with a pair of pre-installed 3+1 and 4+1 outlet sanitary manifolds, suitable for wall recessing even in
bathrooms covered with tiles or valuable materials. The reduced size allows it to be installed in brick or plasterboard walls
with a minimum thickness of 60 mm. The manifolds are compatible with drinking water and the inlets can be shut off
by screw sealing valves and replaceable headworks. Available in two colours (white and chrome), also in the completely
inspectable version.

EMCS compliant

.RFA .PDF

Distribuidor para calefacción y aire acondicionado

IVAR

Descargar
IVAR IVAR ESAT DUAL

IVAR ESAT DUAL

IVAR E-SAT DUAL is a double heat exchanger satellite module which allows on-site production of DHW and hot water for the heating system, with only AFS connections and technical water supply/return. Thanks to the integrated electronics IVAR E-SAT modulates the technical water flow to guarantee a low return temperature to the boiler. The double exchanger solution, completely separating the centralized system from the domestic one, guarantees easy maintenance of the single user system. IVAR ESAT DUAL can be equipped with differential pressure valves and shut-off valves kit.

IVAR

IVAR ESAT DUAL

IVAR E-SAT DUAL is a double heat exchanger satellite module which allows on-site production of DHW and hot water for the heating system, with only AFS connections and technical water supply/return. Thanks to the integrated electronics IVAR E-SAT modulates the technical water flow to guarantee a low return temperature to the boiler. The double exchanger solution, completely separating the centralized system from the domestic one, guarantees easy maintenance of the single user system.
IVAR ESAT DUAL can be equipped with differential pressure valves and shut-off valves kit.

EMCS compliant

.RFA .PDF

Distribuidor para calefacción y aire acondicionado

IVAR

Descargar
Roth Roth Thermaset

Roth Thermaset

Roth Thermaset Distributor

Roth

Roth Thermaset

Roth Thermaset Distributor

EMCS compliant

.RFA

Componentes para instalaciones de saneamiento y de alcantarillado

Roth

Descargar
Valsir HDPE Ring seal socket with cap

HDPE Ring seal socket with cap

Ring seal socket with cap

Valsir

HDPE Ring seal socket with cap

Ring seal socket with cap

EMCS compliant

.RFA

Componentes para instalaciones de saneamiento y de alcantarillado

Valsir

Descargar
Legrand Legrand Cablofil Cable trays

Legrand Cablofil Cable trays

Families for Legrand Cablofil Mesh cable trays

Legrand

Legrand Cablofil Cable trays

Families for Legrand Cablofil Mesh cable trays

EMCS compliant

.RFA

Componentes eléctricos

Legrand

Descargar
Legrand Legrand DLP Wall trays

Legrand DLP Wall trays

Families for Legrand DLP Wall trays

Legrand

Legrand DLP Wall trays

Families for Legrand DLP Wall trays

EMCS compliant

.RFA

Componentes eléctricos

Legrand

Descargar
Valsir PP3 PP 87°30’ bend with front inlet with seal

PP3 PP 87°30’ bend with front inlet with seal

87°30’ bend with front inlet with seal

Valsir

PP3 PP 87°30’ bend with front inlet with seal

87°30’ bend with front inlet with seal

EMCS compliant

.RFA

Componentes para instalaciones de saneamiento y de alcantarillado

Valsir

Descargar
IVAR CUBODOMO®

CUBODOMO®

Smart system for managing the heating system remotely via app. It allows remote control of all the zones in the house through time slots. Compatible with autonomous or centralized heating systems, at high or low temperature (e.g. radiators, radiant floor or ceiling, fan-coil). It can be used in public or private environment thanks to tamper controls. Installation of temperature sensors with no electrical connection. Temperature sensor with relay replaces the main chronothermostat and manages the switching on/off of the boiler (or zone valve with appropriate wiring). Operating system compatible with MyCubodomo App: Android 5.0 and iOS 8.0 onwards. Operating temperature range: -5 – 45 °C. Transmission frequency: 868,3 MHz. Signal range: 30 meters. Cube: power supply 5 V/1 A micro USB, Wi-Fi Standard FCC/CE/TELEC/KCC/SRRC/IC/NCC, protocollo Wi-Fi 802.11 b/g/n, frequency 2.4 GHz ~ 2.5 GHz (2400M ~ 2483.5M), dimensions (W x H x D) 100 x 100 x 100 mm. Temperature sensor (with or without relay): power supply 2 alkaline batteries AA (mod. LR6) 1.5 V, hysteresis on the set point temperature On-Off +/- 0,1°C, average battery life 3 years, dimensions (W x H x D) 87 x 87 x 28 mm. Actuator: power supply 3 alkaline batteries AA (mod. LR6) 1.5 V, connection M30x1.5, maximum closing distance 12 mm, insulation CLASS III, average battery life 3 years. Dimensions (W x H x D) 92 x 48 x 66 mm. Wiring Center: control unit equipped with radio module, power supply 230V 50/60 Hz, fuses F3 15A/250V, output switching relay max 2A/230V AC - 2A/30V DC, dimensions (W x H x D) 180 x 130 x 65 mm.

IVAR

CUBODOMO®

Smart system for managing the heating system remotely via app. It allows remote control of all the zones in the house through time slots. Compatible with autonomous or centralized heating systems, at high or low temperature (e.g. radiators, radiant floor or ceiling, fan-coil). It can be used in public or private environment thanks to tamper controls. Installation of temperature sensors with no electrical connection. Temperature sensor with relay replaces the main chronothermostat and manages the switching on/off of the boiler (or zone valve with appropriate wiring). Operating system compatible with MyCubodomo App: Android 5.0 and iOS 8.0 onwards. Operating temperature range: -5 – 45 °C. Transmission frequency: 868,3 MHz. Signal range: 30 meters. Cube: power supply 5 V/1 A micro USB, Wi-Fi Standard FCC/CE/TELEC/KCC/SRRC/IC/NCC, protocollo Wi-Fi 802.11 b/g/n, frequency 2.4 GHz ~ 2.5 GHz (2400M ~ 2483.5M), dimensions (W x H x D) 100 x 100 x 100 mm. Temperature sensor (with or without relay): power supply 2 alkaline batteries AA (mod. LR6) 1.5 V, hysteresis on the set point temperature On-Off +/- 0,1°C, average battery life 3 years, dimensions (W x H x D) 87 x 87 x 28 mm. Actuator: power supply 3 alkaline batteries AA (mod. LR6) 1.5 V, connection M30x1.5, maximum closing distance 12 mm, insulation CLASS III, average battery life 3 years. Dimensions (W x H x D) 92 x 48 x 66 mm. Wiring Center: control unit equipped with radio module, power supply 230V 50/60 Hz, fuses F3 15A/250V, output switching relay max 2A/230V AC - 2A/30V DC, dimensions (W x H x D) 180 x 130 x 65 mm.

EMCS compliant

.RFA

Control motor

IVAR

Descargar
Oventrop Valve Disc with FKM Seal

Valve Disc with FKM Seal

Bronze piston type spring assisted check valve

Oventrop

Valve Disc with FKM Seal

Bronze piston type spring assisted check valve

EMCS compliant

.DWG .RFA .IFC

Válvula para instalaciones mecánicas

Oventrop

Descargar
Inatherm CK

CK

Standard Fan

Inatherm

CK

Standard Fan

EMCS compliant

.RFA

Fan

Inatherm

Descargar
Inatherm CK EC

CK EC

Standard Fan

Inatherm

CK EC

Standard Fan

EMCS compliant

.RFA

Fan

Inatherm

Descargar
OC Waterloo OLP

OLP

Perforated Standard

OC Waterloo

OLP

Perforated Standard

EMCS compliant

.RFA

Rejilla

OC Waterloo

Descargar
ABB ABB-tacteo Movement detector 180 FM Standard

ABB-tacteo Movement detector 180 FM Standard

TBW/U.1.1-CG Watchdog 180°

ABB

ABB-tacteo Movement detector 180 FM Standard

TBW/U.1.1-CG Watchdog 180°

EMCS compliant

.DWG .RFA .IFC

Detector

ABB

Descargar
OC Waterloo DVC

DVC

Air Terminal Overflow Standard

OC Waterloo

DVC

Air Terminal Overflow Standard

EMCS compliant

.RFA

Rejilla

OC Waterloo

Descargar
Oventrop HydroControl V Double regulating and commissoning valves PN25

HydroControl V Double regulating and commissoning valves PN25

Balancing valve for the hydraulic balancing of distribution lines in central heating and cooling systems with closed circuits. Flow determination by differential pressure measurement taking into account the preset values, e.g. with the OV-DMC3 measuring system. Installation in flow or return. In an angled version with continuously controllable, infinitely fine presetting using a non-rising handwheel. Presetting is reproducible, lockable and sealable as standard. All functional elements on the handwheel side. Equipped with two measuring, draining and filling valves as standard. Valve housing and parts in contact with the medium made of dezincification-resistant brass, EPDM or PTFE. Maintenance-free, double spindle seal. Female thread on both sides according to EN 10226

Oventrop

HydroControl V Double regulating and commissoning valves PN25

Balancing valve for the hydraulic balancing of distribution lines in central heating and cooling systems with closed circuits. Flow determination by differential pressure measurement taking into account the preset values, e.g. with the OV-DMC3 measuring system. Installation in flow or return. In an angled version with continuously controllable, infinitely fine presetting using a non-rising handwheel. Presetting is reproducible, lockable and sealable as standard. All functional elements on the handwheel side. Equipped with two measuring, draining and filling valves as standard. Valve housing and parts in contact with the medium made of dezincification-resistant brass, EPDM or PTFE. Maintenance-free, double spindle seal. Female thread on both sides according to EN 10226

EMCS compliant

.DWG .RFA .IFC

Válvula para instalaciones mecánicas

Oventrop

Descargar
Zehnder Group International AG Sail Configurable Radiant Panel, Passive Panel and Suspension Kits

Sail Configurable Radiant Panel, Passive Panel and Suspension Kits

Ceiling sails for heating and cooling

Zehnder Group International AG

Sail Configurable Radiant Panel, Passive Panel and Suspension Kits

Ceiling sails for heating and cooling

EMCS compliant

.RFA .PDF

Radiator

Zehnder Group International AG

Descargar
TROX RN

RN

Constant volume valve RN Standard

TROX

RN

Constant volume valve RN Standard

EMCS compliant

.RFA

Caja de aire de caudal variable

TROX

Descargar
Mitsubishi Heavy Industries Air Conditioning Europe Hyozan

Hyozan

Heat pump standard inverter outdoor unit

Mitsubishi Heavy Industries Air Conditioning Europe

Hyozan

Heat pump standard inverter outdoor unit

EMCS compliant

.DWG .RFA .IFC

Bomba de calor

Mitsubishi Heavy Industries Air Conditioning Europe

Descargar
Legrand Legrand GLO 4 Ladder tray

Legrand GLO 4 Ladder tray

Families GLO 4 Cable ladder of Legrand

Legrand

Legrand GLO 4 Ladder tray

Families GLO 4 Cable ladder of Legrand

EMCS compliant

.RFA

Componentes eléctricos

Legrand

Descargar
Mitsubishi Electric Ecodan EHPT-UKHCW

Ecodan EHPT-UKHCW

FTC5 pre-plumbed Standard cylinders for Ecodan

Mitsubishi Electric

Ecodan EHPT-UKHCW

FTC5 pre-plumbed Standard cylinders for Ecodan

EMCS compliant

.DWG .RFA .IFC

Bomba de calor

Mitsubishi Electric

Descargar
Legrand Legrand P31 Cable ducts

Legrand P31 Cable ducts

Families for Legrand P31 Cable ducts

Legrand

Legrand P31 Cable ducts

Families for Legrand P31 Cable ducts

EMCS compliant

.RFA

Componentes eléctricos

Legrand

Descargar
Mitsubishi Electric Ecodan EHPT21X-UKHDW1S

Ecodan EHPT21X-UKHDW1S

FTC6 pre-plumbed standard cylinders for ecodan monobloc units

Mitsubishi Electric

Ecodan EHPT21X-UKHDW1S

FTC6 pre-plumbed standard cylinders for ecodan monobloc units

EMCS compliant

.DWG .RFA .IFC

Bomba de calor

Mitsubishi Electric

Descargar
VTE Smarter Solutions SLIM District Heating Steel

SLIM District Heating Steel

1-12 way - SLIM district heating manifold Grundfos-2 standard

VTE Smarter Solutions

SLIM District Heating Steel

1-12 way - SLIM district heating manifold Grundfos-2 standard

EMCS compliant

.DWG .RFA .IFC

Manifold

VTE Smarter Solutions

Descargar
Mitsubishi Electric Ecodan EHPT21-30X-UKHDW1L

Ecodan EHPT21-30X-UKHDW1L

FTC6 pre-plumbed standard cylinders for ecodan monobloc units

Mitsubishi Electric

Ecodan EHPT21-30X-UKHDW1L

FTC6 pre-plumbed standard cylinders for ecodan monobloc units

EMCS compliant

.DWG .RFA .IFC

Bomba de calor

Mitsubishi Electric

Descargar
Mitsubishi Electric Ecodan EHPT21-30X-UKHDWB

Ecodan EHPT21-30X-UKHDWB

FTC6 versatile standard cylinders for ecodan monobloc units

Mitsubishi Electric

Ecodan EHPT21-30X-UKHDWB

FTC6 versatile standard cylinders for ecodan monobloc units

EMCS compliant

.DWG .RFA .IFC

Bomba de calor

Mitsubishi Electric

Descargar
Mitsubishi Electric Ecodan EHPT15-17X-UKHDW1S

Ecodan EHPT15-17X-UKHDW1S

FTC6 pre-plumbed standard cylinders for ecodan monobloc units

Mitsubishi Electric

Ecodan EHPT15-17X-UKHDW1S

FTC6 pre-plumbed standard cylinders for ecodan monobloc units

EMCS compliant

.DWG .RFA .IFC

Bomba de calor

Mitsubishi Electric

Descargar
Spirotech SpiroVent BA F/L

SpiroVent BA F/L

A steel (microbubble) deaerator for standard flow rate (1.5 m/s) with a DN50 - DN300 connection

Spirotech

SpiroVent BA F/L

A steel (microbubble) deaerator for standard flow rate (1.5 m/s) with a DN50 - DN300 connection

EMCS compliant

.DWG .RFA .IFC

Separador para instalaciones mecánicas

Spirotech

Descargar
Spirotech SpiroTrap BE F/L

SpiroTrap BE F/L

A steel dirt separator for standard flow rate (1.5 m/s) with a DN50 - DN300 connection

Spirotech

SpiroTrap BE F/L

A steel dirt separator for standard flow rate (1.5 m/s) with a DN50 - DN300 connection

EMCS compliant

.DWG .RFA .IFC

Separador para instalaciones mecánicas

Spirotech

Descargar
Viega Cup siphon plug cup 5754

Cup siphon plug cup 5754

Cup Ø 50 mm, universal valve, valve sealing plug, flat seal for valve top, adjustment tube 100 mm, drain tube 200 mm

Viega

Cup siphon plug cup 5754

Cup Ø 50 mm, universal valve, valve sealing plug, flat seal for valve top, adjustment tube 100 mm, drain tube 200 mm

EMCS compliant

.DWG .RFA .IFC

Sifón

Viega

Descargar
Mitsubishi Heavy Industries Air Conditioning Europe FDTQ-KXE6F

FDTQ-KXE6F

Ceiling cassette -1way Compact - Indoor Unit - Compact design for Comfortable effective cooling for small rooms. - Ultra slim design at just 250mm above the ceiling. - Standard built- in drain pump. - Fit in to Standard 600 x 600 ceiling panel.

Mitsubishi Heavy Industries Air Conditioning Europe

FDTQ-KXE6F

Ceiling cassette -1way Compact - Indoor Unit
- Compact design for Comfortable effective cooling for small rooms.
- Ultra slim design at just 250mm above the ceiling.
- Standard built- in drain pump.
- Fit in to Standard 600 x 600 ceiling panel.

EMCS compliant

.DWG .RFA .IFC

Unidad de aire acondicionado

Mitsubishi Heavy Industries Air Conditioning Europe

Descargar
Spirotech SpiroCombi BC F/L

SpiroCombi BC F/L

A steel (microbubble) deaerator and dirt separator for standard flow rate (1.5 m/s) with a DN50 - DN300 PN16 connection

Spirotech

SpiroCombi BC F/L

A steel (microbubble) deaerator and dirt separator for standard flow rate (1.5 m/s) with a DN50 - DN300 PN16 connection

EMCS compliant

.DWG .RFA .IFC

Separador para instalaciones mecánicas

Spirotech

Descargar
Spirotech SpiroTrap BE FM/LM

SpiroTrap BE FM/LM

A steel dirt separator with magnet for standard flow rate (1.5 m/s) with a DN50 - DN300 connection

Spirotech

SpiroTrap BE FM/LM

A steel dirt separator with magnet for standard flow rate (1.5 m/s) with a DN50 - DN300 connection

EMCS compliant

.DWG .RFA .IFC

Separador para instalaciones mecánicas

Spirotech

Descargar
Orcon HRC OptiAir-260/360-EU

HRC OptiAir-260/360-EU

Heat recovery ventilation unit – ceiling, wall, floor mounting. Remark: Flange for connected duct connection is standard available for OptiAir 260 with 160 mm and OptiAir 360 with 180 mm.

Orcon

HRC OptiAir-260/360-EU

Heat recovery ventilation unit – ceiling, wall, floor mounting. Remark: Flange for connected duct connection is standard available for OptiAir 260 with 160 mm and OptiAir 360 with 180 mm.

EMCS compliant

.DWG .RFA .IFC

Intercambiador térmico para ventilación

Orcon

Descargar
Spirotech SpiroCombi BC FM/LM

SpiroCombi BC FM/LM

A steel (microbubble) deaerator and dirt separator with magnet for standard flow rate (1.5 m/s) with a DN50 - DN300 connection

Spirotech

SpiroCombi BC FM/LM

A steel (microbubble) deaerator and dirt separator with magnet for standard flow rate (1.5 m/s) with a DN50 - DN300 connection

EMCS compliant

.DWG .RFA .IFC

Separador para instalaciones mecánicas

Spirotech

Descargar
Mitsubishi Heavy Industries Air Conditioning Europe PAC-FDC90VNP1 / -W

PAC-FDC90VNP1 / -W

Heat pump standard inverter - Outdoor unit - The Standard Inverter range offers high seasonal performance up to level A++ in cooling mode - Component technology contributing to environmental protection with a range operating with R32 (-W) and another with R410A - Heat exchanger fins treated with a specific coating offering a high level of protection against corrosion - Design flexibility optimised with a compatible piping length up to 30 m and a precharged piping length of 15 m

Mitsubishi Heavy Industries Air Conditioning Europe

PAC-FDC90VNP1 / -W

Heat pump standard inverter - Outdoor unit
- The Standard Inverter range offers high seasonal performance up to level A++ in cooling mode
- Component technology contributing to environmental protection with a range operating with R32 (-W) and another with R410A
- Heat exchanger fins treated with a specific coating offering a high level of protection against corrosion
- Design flexibility optimised with a compatible piping length up to 30 m and a precharged piping length of 15 m

EMCS compliant

.DWG .RFA .IFC

Bomba de calor

Mitsubishi Heavy Industries Air Conditioning Europe

Descargar
Mitsubishi Heavy Industries Air Conditioning Europe PAC-FDC200-280VSA-W

PAC-FDC200-280VSA-W

Heat pump micro inverter - Outdoor unit - High cooling capacity under standard conditions and operates efficiently in extreme conditions down to -15 C - Freedom of piping layout increased by providing 4 possible configurations of refrigerant piping - Equipped with 4 handles at the same level and on each side of the unit to facilitate the handling and installation - Plastic cover is mounted over control boards in standard to facilitate the maintenance - Precharged piping length of 30 m

Mitsubishi Heavy Industries Air Conditioning Europe

PAC-FDC200-280VSA-W

Heat pump micro inverter - Outdoor unit - High cooling capacity under standard conditions and operates efficiently in extreme conditions down to -15 C - Freedom of piping layout increased by providing 4 possible configurations of refrigerant piping - Equipped with 4 handles at the same level and on each side of the unit to facilitate the handling and installation - Plastic cover is mounted over control boards in standard to facilitate the maintenance - Precharged piping length of 30 m

EMCS compliant

.DWG .RFA .IFC

Bomba de calor

Mitsubishi Heavy Industries Air Conditioning Europe

Descargar
Mitsubishi Heavy Industries Air Conditioning Europe PAC-FDC100VNP

PAC-FDC100VNP

Heat pump standard inverter - Outdoor unit - Standard Inverter range offers high seasonal performance up to level A++ in cooling mode - Heat exchanger fins treated with a specific coating offering a high level of protection against corrosion - Design flexibility optimised with a compatible piping length up to 30 m with a precharged piping length of 15 m

Mitsubishi Heavy Industries Air Conditioning Europe

PAC-FDC100VNP

Heat pump standard inverter - Outdoor unit - Standard Inverter range offers high seasonal performance up to level A++ in cooling mode - Heat exchanger fins treated with a specific coating offering a high level of protection against corrosion - Design flexibility optimised with a compatible piping length up to 30 m with a precharged piping length of 15 m

EMCS compliant

.DWG .RFA .IFC

Bomba de calor

Mitsubishi Heavy Industries Air Conditioning Europe

Descargar
Mitsubishi Heavy Industries Air Conditioning Europe PAC-FDC100VNP-W

PAC-FDC100VNP-W

Heat pump standard inverter - Outdoor unit - The Standard Inverter range offers high seasonal performance up to level A++ in cooling mode - Component technology contributing to environmental protection with a range operating with R32 (-W) - Heat exchanger fins treated with a specific coating offering a high level of protection against corrosion - Design flexibility optimised with a compatible piping length up to 30 m and a precharged piping length of 15 m

Mitsubishi Heavy Industries Air Conditioning Europe

PAC-FDC100VNP-W

Heat pump standard inverter - Outdoor unit
- The Standard Inverter range offers high seasonal performance up to level A++ in cooling mode
- Component technology contributing to environmental protection with a range operating with R32 (-W)
- Heat exchanger fins treated with a specific coating offering a high level of protection against corrosion
- Design flexibility optimised with a compatible piping length up to 30 m and a precharged piping length of 15 m

EMCS compliant

.DWG .RFA .IFC

Bomba de calor

Mitsubishi Heavy Industries Air Conditioning Europe

Descargar
Mitsubishi Heavy Industries Air Conditioning Europe PAC-FDC125VNP-W

PAC-FDC125VNP-W

Heat pump standard inverter - Outdoor unit 1.The Standard Inverter range offers high seasonal performance up to level A++ in cooling mode 2. Component technology contributing to environmental protection with a range operating with R32 (-W) 3.Heat exchanger fins treated with a specific coating offering a high level of protection against corrosion 4.Design flexibility optimised with a compatible piping length up to 30 m and a precharged piping length of 15 m

Mitsubishi Heavy Industries Air Conditioning Europe

PAC-FDC125VNP-W

Heat pump standard inverter - Outdoor unit 1.The Standard Inverter range offers high seasonal performance up to level A++ in cooling mode 2. Component technology contributing to environmental protection with a range operating with R32 (-W) 3.Heat exchanger fins treated with a specific coating offering a high level of protection against corrosion 4.Design flexibility optimised with a compatible piping length up to 30 m and a precharged piping length of 15 m

EMCS compliant

.DWG .RFA .IFC

Bomba de calor

Mitsubishi Heavy Industries Air Conditioning Europe

Descargar
Mitsubishi Heavy Industries Air Conditioning Europe PAC-FDC200VSA

PAC-FDC200VSA

Heat pump micro inverter - Outdoor unit - Supplies 19 kW under standard cooling mode conditions and operates efficiently in extreme conditions down to -15 C - Freedom of piping layout increased by providing 4 possible configurations of refrigerant piping - Equipped with 4 handles at the same level and on each side of the unit to facilitate the handling and installation - Plastic cover is mounted over control boards in standard to facilitate the maintenance - Design flexibility optimised with a compatible piping length up to 70 m and a precharged piping length of 30 m

Mitsubishi Heavy Industries Air Conditioning Europe

PAC-FDC200VSA

Heat pump micro inverter - Outdoor unit
- Supplies 19 kW under standard cooling mode conditions and operates efficiently in extreme conditions down to -15 C
- Freedom of piping layout increased by providing 4 possible configurations of refrigerant piping
- Equipped with 4 handles at the same level and on each side of the unit to facilitate the handling and installation
- Plastic cover is mounted over control boards in standard to facilitate the maintenance
- Design flexibility optimised with a compatible piping length up to 70 m and a precharged piping length of 30 m

EMCS compliant

.DWG .RFA .IFC

Bomba de calor

Mitsubishi Heavy Industries Air Conditioning Europe

Descargar
Mitsubishi Heavy Industries Air Conditioning Europe FDC-KXZE1

FDC-KXZE1

KXZE1 (Standard)- Heat Pump VRF outdoor unit Standard module VRF, 28 kW to 168 kW in cooling - High level of design flexibility, - High efficiency as well as enhanced operational functions: - Variable Temperature and capacity control (VTCC) - Peak cut control which can manage system energy control - Improved Scroll Compressor: the combination of the new multi discharge compressor port and the new concentrated - Wide Range of Operation: -20ºC in heating and up tp 46ºC in cooling. - Connect up to 80 indoor units for large models, with 130% by capacity - Wide range of controls, central controls and BMS systems are available.

Mitsubishi Heavy Industries Air Conditioning Europe

FDC-KXZE1

KXZE1 (Standard)- Heat Pump VRF outdoor unit
Standard module VRF, 28 kW to 168 kW in cooling
- High level of design flexibility,
- High efficiency as well as enhanced operational functions: - Variable Temperature and capacity control (VTCC)
- Peak cut control which can manage system energy control
- Improved Scroll Compressor: the combination of the new multi discharge compressor port and the new concentrated - Wide Range of Operation: -20ºC in heating and up tp 46ºC in cooling.
- Connect up to 80 indoor units for large models, with 130% by capacity
- Wide range of controls, central controls and BMS systems are available.

EMCS compliant

.DWG .RFA .IFC

Bomba de calor

Mitsubishi Heavy Industries Air Conditioning Europe

Descargar
IVAR RTV Thermostatic Valve For Recirculation Branch Balancing

RTV Thermostatic Valve For Recirculation Branch Balancing

IVAR RTV: thermostatic valve for controlling the water temperature in the recirculation branches. Balancing thermostatic insert with fixed point adjustment settable with graduated knob equipped with locking mechanism. Version A with only recirculation branch balancing. Version B with thermostatic control for thermal disinfection cycle. Version C with electronic thermal disinfection cycle. Connections: 1/2" F or 3/4" F. Adjustment range 35-60 °C. ΔP maximum at the ends of the valve 1 bar. Main material: brass CW617N. Adjustment knob: ABS. O-ring seal: peroxide EPDM.

IVAR

RTV Thermostatic Valve For Recirculation Branch Balancing

IVAR RTV: thermostatic valve for controlling the water temperature in the recirculation branches. Balancing thermostatic insert with fixed point adjustment settable with graduated knob equipped with locking mechanism. Version A with only recirculation branch balancing. Version B with thermostatic control for thermal disinfection cycle. Version C with electronic thermal disinfection cycle. Connections: 1/2" F or 3/4" F. Adjustment range 35-60 °C. ΔP maximum at the ends of the valve 1 bar. Main material: brass CW617N. Adjustment knob: ABS. O-ring seal: peroxide EPDM.

EMCS compliant

.RVT .RFA

Válvula para calefacción y refrigeración

IVAR

Descargar
Mitsubishi Heavy Industries Air Conditioning Europe PAC-FDC71VNP / -W

PAC-FDC71VNP / -W

Heat pump standard inverter - Outdoor unit - The Standard Inverter range offers high seasonal performance up to level A++ in cooling mode - Component technology contributing to environmental protection with a range operating with R32 (-W) and another with R410A - Heat exchanger fins treated with a specific coating offering a high level of protection against corrosion - Design flexibility optimised with a compatible piping length up to 30 m and a precharged piping length of 15 m

Mitsubishi Heavy Industries Air Conditioning Europe

PAC-FDC71VNP / -W

Heat pump standard inverter - Outdoor unit
- The Standard Inverter range offers high seasonal performance up to level A++ in cooling mode
- Component technology contributing to environmental protection with a range operating with R32 (-W) and another with R410A
- Heat exchanger fins treated with a specific coating offering a high level of protection against corrosion
- Design flexibility optimised with a compatible piping length up to 30 m and a precharged piping length of 15 m

EMCS compliant

.DWG .RFA .IFC

Bomba de calor

Mitsubishi Heavy Industries Air Conditioning Europe

Descargar
Mitsubishi Heavy Industries Air Conditioning Europe PAC-FDC250VSA

PAC-FDC250VSA

Heat pump micro inverter - Outdoor unit - Supplies 24 kW under standard cooling mode conditions and operates efficiently in extreme conditions down to -15 C - Freedom of piping layout increased by providing 4 possible configurations of refrigerant piping - Equipped with 4 handles at the same level and on each side of the unit to facilitate the handling and installation - Plastic cover is mounted over control boards in standard to facilitate the maintenance - Design flexibility optimised with a compatible piping length up to 70 m and a precharged piping length of 30 m

Mitsubishi Heavy Industries Air Conditioning Europe

PAC-FDC250VSA

Heat pump micro inverter - Outdoor unit
- Supplies 24 kW under standard cooling mode conditions and operates efficiently in extreme conditions down to -15 C
- Freedom of piping layout increased by providing 4 possible configurations of refrigerant piping
- Equipped with 4 handles at the same level and on each side of the unit to facilitate the handling and installation
- Plastic cover is mounted over control boards in standard to facilitate the maintenance
- Design flexibility optimised with a compatible piping length up to 70 m and a precharged piping length of 30 m

EMCS compliant

.DWG .RFA .IFC

Bomba de calor

Mitsubishi Heavy Industries Air Conditioning Europe

Descargar
Mitsubishi Heavy Industries Air Conditioning Europe FDC-KXE6

FDC-KXE6

KX6 (Standard)- Heat Pump VRF outdoor unit Standard single module VRF, 61.5 to 68.0kW in cooling - The KX6 heat pump 2-pipe systems offer high performance VRF for applications that require either cooling only or heating only, ideal for open plan areas. - KX6 employs DC inverter compressors ONLY. - Connect up to 49 indoor units/up to 160% capacity. - High efficiency with COP (in cooling) up to 3.4. - Industry leading total piping length up to 1000m and a maximum pipe run of 160m. - Wide range of controls, central controls and BMS systems are available.

Mitsubishi Heavy Industries Air Conditioning Europe

FDC-KXE6

KX6 (Standard)- Heat Pump VRF outdoor unit
Standard single module VRF, 61.5 to 68.0kW in cooling
- The KX6 heat pump 2-pipe systems offer high performance VRF for applications that require either cooling only or heating only, ideal for open plan areas.
- KX6 employs DC inverter compressors ONLY.
- Connect up to 49 indoor units/up to 160% capacity.
- High efficiency with COP (in cooling) up to 3.4.
- Industry leading total piping length up to 1000m and a maximum pipe run of 160m.
- Wide range of controls, central controls and BMS systems are available.

EMCS compliant

.DWG .RFA .IFC

Bomba de calor

Mitsubishi Heavy Industries Air Conditioning Europe

Descargar
Mitsubishi Heavy Industries Air Conditioning Europe FDC-KXZ(X)E2

FDC-KXZ(X)E2

VRF Standard Heat pump - Outdoor unit (R410A) - Standard VRF module (FDC-KXZE2) with a cooling range from 28 kW to 168 kW - Hi COP VRF module (FDC-KXZXE2) with a cooling range from 56 kW to 112 kW - Design flexibility thanks to fan external static pressure of 85 Pa - Wide range of operation down to -20ºC in heating and up to +46ºC in cooling - Connected capacity up to 200% and large number of connected indoor units (up to 80 for large sizes) - Wide range of controls, central controls and BMS systems are available

Mitsubishi Heavy Industries Air Conditioning Europe

FDC-KXZ(X)E2

VRF Standard Heat pump - Outdoor unit (R410A) - Standard VRF module (FDC-KXZE2) with a cooling range from 28 kW to 168 kW - Hi COP VRF module (FDC-KXZXE2) with a cooling range from 56 kW to 112 kW - Design flexibility thanks to fan external static pressure of 85 Pa - Wide range of operation down to -20ºC in heating and up to +46ºC in cooling - Connected capacity up to 200% and large number of connected indoor units (up to 80 for large sizes) - Wide range of controls, central controls and BMS systems are available

EMCS compliant

.DWG .RFA .IFC

Bomba de calor

Mitsubishi Heavy Industries Air Conditioning Europe

Descargar
Mitsubishi Heavy Industries Air Conditioning Europe FDU-KXE6F-W

FDU-KXE6F-W

VRF ducted high static pressure - Indoor unit (R32) - Adjustable external static pressure by wired remote controller - Wide external static pressure: from 10 to 200 Pa - Installation flexibility as thin design with 280mm height - Standard built- in drain pump - Transparent access hole to drain pan to check the drain pan without removing drain pan - Reduced energy consumption by applying DC fan motor

Mitsubishi Heavy Industries Air Conditioning Europe

FDU-KXE6F-W

VRF ducted high static pressure - Indoor unit (R32) - Adjustable external static pressure by wired remote controller - Wide external static pressure: from 10 to 200 Pa - Installation flexibility as thin design with 280mm height - Standard built- in drain pump - Transparent access hole to drain pan to check the drain pan without removing drain pan - Reduced energy consumption by applying DC fan motor

EMCS compliant

.DWG .RFA .IFC

Unidad de aire acondicionado

Mitsubishi Heavy Industries Air Conditioning Europe

Descargar
Mitsubishi Heavy Industries Air Conditioning Europe RAC-FDTC25-35VF

RAC-FDTC25-35VF

Ceiling Cassette 4way compact - Indoor Unit - Compact design with flat panels that perfectly fits into standard ceiling (600 x 600) - Individual Flap Control System: four directions of air flow can be controlled individually - Flap Control System: individual flaps can be set at different angles - Drain can be discharged up to 600mm from the ceiling surface and allows high degree of freedom

Mitsubishi Heavy Industries Air Conditioning Europe

RAC-FDTC25-35VF

Ceiling Cassette 4way compact - Indoor Unit
- Compact design with flat panels that perfectly fits into standard ceiling (600 x 600)
- Individual Flap Control System: four directions of air flow can be controlled individually
- Flap Control System: individual flaps can be set at different angles
- Drain can be discharged up to 600mm from the ceiling surface and allows high degree of freedom

EMCS compliant

.DWG .RFA .IFC

Unidad de aire acondicionado

Mitsubishi Heavy Industries Air Conditioning Europe

Descargar
Mark Climate Technology Ceilfit Panel Radiante

Ceilfit Panel Radiante

The Mark CEILFIT radiant panel creates a comfortable work and living environment through heating and cooling by convection and radiation. It is easy to regulate zones or rooms individually to ensure a pleasant surrounding. The Mark CEILFIT panels are compatible with grid type ceilings and can replace the standard tile without any additional work to the grid. The standard panels are available in common standard grid dimension, or as custom dimensions on request. Features - Easily installed in standard T-Grid ceiling - Cost efficient heating and cooling - RAL 9010 powder coated - Constructed of 0,7 steel sheet fused to copper tube - Copper tubing (10×0,4mm) can withstand pressure up to 6 bar - Easy to clean - Frees up floor and wall space - Rapid warm up times, due to low water content - Low pressure drop (operating pressures) - Low whole life costs – lack of moving parts - In accordance with NEN-EN 13964 regulation - Optional: perforation for better sound absorption To support the weight of a fluid filled panel we strongly advise to add suspension wires from the panels to a structural part of the building or ceiling. The panels are accomodated with several holes to fix the supension brackets or cables.

Mark Climate Technology

Ceilfit Panel Radiante

The Mark CEILFIT radiant panel creates a comfortable work and living environment through heating and cooling by convection and radiation. It is easy to regulate zones or rooms individually to ensure a pleasant surrounding. The Mark CEILFIT panels are compatible with grid type ceilings and can replace the standard tile without any additional work to the grid. The standard panels are available in common standard grid dimension, or as custom dimensions on request. Features - Easily installed in standard T-Grid ceiling - Cost efficient heating and cooling - RAL 9010 powder coated - Constructed of 0,7 steel sheet fused to copper tube - Copper tubing (10×0,4mm) can withstand pressure up to 6 bar - Easy to clean - Frees up floor and wall space - Rapid warm up times, due to low water content - Low pressure drop (operating pressures) - Low whole life costs – lack of moving parts - In accordance with NEN-EN 13964 regulation - Optional: perforation for better sound absorption To support the weight of a fluid filled panel we strongly advise to add suspension wires from the panels to a structural part of the building or ceiling. The panels are accomodated with several holes to fix the supension brackets or cables.

EMCS compliant

.DWG .RFA .IFC

Radiator

Mark Climate Technology

Descargar
Mitsubishi Heavy Industries Air Conditioning Europe FDUM-KXE6F-W

FDUM-KXE6F-W

VRF ducted low/middle static pressure - Indoor unit (R32) - Adjustable external static pressure by wired remote controller - Wide external static pressure: from 10 to 100 Pa - Installation flexibility as thin design with 280mm height - Standard built- in drain pump - Transparent access hole to drain pan to check the drain pan without removing drain pan - Reduced energy consumption by applying DC fan motor

Mitsubishi Heavy Industries Air Conditioning Europe

FDUM-KXE6F-W

VRF ducted low/middle static pressure - Indoor unit (R32) - Adjustable external static pressure by wired remote controller - Wide external static pressure: from 10 to 100 Pa - Installation flexibility as thin design with 280mm height - Standard built- in drain pump - Transparent access hole to drain pan to check the drain pan without removing drain pan - Reduced energy consumption by applying DC fan motor

EMCS compliant

.DWG .RFA .IFC

Unidad de aire acondicionado

Mitsubishi Heavy Industries Air Conditioning Europe

Descargar
Mitsubishi Heavy Industries Air Conditioning Europe FDUT-KXE6F

FDUT-KXE6F

Duct Connected-Low Static Pressure(thin) - Indoor Unit - Compact ducted unit with slim design (200mm height & 500mm Depth). - Interchangeable return air inlet (bottom or front) (*) with optional part - Low sound level: the low sound level can ensure comfortable stay and rest in hotels - Standard built- in drain pump,

Mitsubishi Heavy Industries Air Conditioning Europe

FDUT-KXE6F

Duct Connected-Low Static Pressure(thin) - Indoor Unit - Compact ducted unit with slim design (200mm height & 500mm Depth). - Interchangeable return air inlet (bottom or front) (*) with optional part - Low sound level: the low sound level can ensure comfortable stay and rest in hotels - Standard built- in drain pump,

EMCS compliant

.DWG .RFA .IFC

Unidad de aire acondicionado

Mitsubishi Heavy Industries Air Conditioning Europe

Descargar
Mitsubishi Heavy Industries Air Conditioning Europe RAC-SKM20-35ZSP-S

RAC-SKM20-35ZSP-S

Wall mounted Standard Series - Indoor Unit - Elegant design that fits into any kind of interior decoration - Long reach airflow is achieved by using Jet Air technology (same technology as blade shape of jet engine) - Flap control system: flap can be set to wide angle position to provide a comfortable air flow - Cleaning and maintenance are easier than ever thanks to the removable cover - Two available ranges compatible with R32 (-W) or R410 (-S) and single / multi systems

Mitsubishi Heavy Industries Air Conditioning Europe

RAC-SKM20-35ZSP-S

Wall mounted Standard Series - Indoor Unit
- Elegant design that fits into any kind of interior decoration
- Long reach airflow is achieved by using Jet Air technology (same technology as blade shape of jet engine)
- Flap control system: flap can be set to wide angle position to provide a comfortable air flow
- Cleaning and maintenance are easier than ever thanks to the removable cover
- Two available ranges compatible with R32 (-W) or R410 (-S) and single / multi systems

EMCS compliant

.DWG .RFA .IFC

Unidad de aire acondicionado

Mitsubishi Heavy Industries Air Conditioning Europe

Descargar
Mitsubishi Heavy Industries Air Conditioning Europe FDU-KXE6F

FDU-KXE6F

Duct Connected-High static pressure - Indoor Unit - Adjustable external static pressure by wired remote controller - Wide external static pressure: from 10 to 200 Pa. - Installation flexibility as thin design with 280mm height. - Standard built- in drain pump, - Transparent access hole to drain pan to check the drain pan without removing drain pan. - Reduced energy consumption by applying DC fan motor. - Reduction of sound pressure level down to 25dBA.

Mitsubishi Heavy Industries Air Conditioning Europe

FDU-KXE6F

Duct Connected-High static pressure - Indoor Unit
- Adjustable external static pressure by wired remote controller
- Wide external static pressure: from 10 to 200 Pa.
- Installation flexibility as thin design with 280mm height.
- Standard built- in drain pump,
- Transparent access hole to drain pan to check the drain pan without removing drain pan.
- Reduced energy consumption by applying DC fan motor.
- Reduction of sound pressure level down to 25dBA.

EMCS compliant

.DWG .RFA .IFC

Unidad de aire acondicionado

Mitsubishi Heavy Industries Air Conditioning Europe

Descargar
Mitsubishi Heavy Industries Air Conditioning Europe FDUT-KXE6F-W

FDUT-KXE6F-W

VRF ducted thin low static pressure - Indoor unit (R32) - Compact ducted unit with slim design (200mm height & 500mm depth) - Interchangeable return air inlet (bottom or front) with optional part - Low sound level ensuring a comfortable stay and rest in hotels - Standard built- in drain pump

Mitsubishi Heavy Industries Air Conditioning Europe

FDUT-KXE6F-W

VRF ducted thin low static pressure - Indoor unit (R32) - Compact ducted unit with slim design (200mm height & 500mm depth) - Interchangeable return air inlet (bottom or front) with optional part - Low sound level ensuring a comfortable stay and rest in hotels - Standard built- in drain pump

EMCS compliant

.DWG .RFA .IFC

Unidad de aire acondicionado

Mitsubishi Heavy Industries Air Conditioning Europe

Descargar
Mitsubishi Heavy Industries Air Conditioning Europe FDUM-KXE6F

FDUM-KXE6F

Duct Connected-Low/Middle Static Pressure - Indoor Unit - Adjustable external static pressure by wired remote controller - Wide external static pressure: from 10 to 100 Pa. - Installation flexibility as thin design with 280mm height. - Standard built- in drain pump, - Transparent access hole to drain pan to check the drain pan without removing drain pan. - Reduced energy consumption by applying DC fan motor. - Reduction of sound pressure level down to 25dBA.

Mitsubishi Heavy Industries Air Conditioning Europe

FDUM-KXE6F

Duct Connected-Low/Middle Static Pressure - Indoor Unit - Adjustable external static pressure by wired remote controller - Wide external static pressure: from 10 to 100 Pa. - Installation flexibility as thin design with 280mm height. - Standard built- in drain pump, - Transparent access hole to drain pan to check the drain pan without removing drain pan. - Reduced energy consumption by applying DC fan motor. - Reduction of sound pressure level down to 25dBA.

EMCS compliant

.DWG .RFA .IFC

Unidad de aire acondicionado

Mitsubishi Heavy Industries Air Conditioning Europe

Descargar
Mitsubishi Heavy Industries Air Conditioning Europe FDC-KXZR(X)E2

FDC-KXZR(X)E2

VRF Heat Recovery Heat pump - Outdoor unit (R410A) - Simultaneous heating and cooling operations of individual indoor units - Standard VRF module (FDC-KXZRE2) with a cooling range from 22.4 kW to 168 kW - Hi COP VRF module (FDC-KXZRXE2) with a cooling range from 45.0 kW to 100 kW - Total piping length up to 1000m and a maximum pipe run of 160m - Wide range of controls, central controls and BMS systems are available

Mitsubishi Heavy Industries Air Conditioning Europe

FDC-KXZR(X)E2

VRF Heat Recovery Heat pump - Outdoor unit (R410A) - Simultaneous heating and cooling operations of individual indoor units - Standard VRF module (FDC-KXZRE2) with a cooling range from 22.4 kW to 168 kW - Hi COP VRF module (FDC-KXZRXE2) with a cooling range from 45.0 kW to 100 kW - Total piping length up to 1000m and a maximum pipe run of 160m - Wide range of controls, central controls and BMS systems are available

EMCS compliant

.DWG .RFA .IFC

Bomba de calor

Mitsubishi Heavy Industries Air Conditioning Europe

Descargar
IVAR TECHNOMIX

TECHNOMIX

IVAR TECHNO TNB cod. 508100: mixing and boosting unit for radiant installations complete with two-way mixing valve, balancing valve (on the cold way), fill/drain valve, manual air vent valve, two thermometers 0÷80 °C (on delivery of boiler circuit and mixed circuit), temperature sensor pocket (on delivery of mixed circuit), shut off valve (on return of boiler circuit), boiler circuit connections G 1”F (centre distance 200 mm) and mixed circuit connections G 1”M (centre distance 200 mm). Upper and lower parts made of nickel-plated CB753S brass; pipe made of nickel-plated half-hard copper; gaskets and O-rings made of peroxide-cured EPDM; other parts made of CW617N brass. Max operating temperature 100 °C. Max operating pressure 10 bar. Fixed point mixing 20÷60 °C by thermostatic control head with remote sensor T3011 included. Max differential pressure at mixing valve ends 250 mbar. Pump space 130 mm with G 1”1/2F flat seal connections.

IVAR

TECHNOMIX

IVAR TECHNO TNB cod. 508100: mixing and boosting unit for radiant installations complete with two-way mixing valve, balancing valve (on the cold way), fill/drain valve, manual air vent valve, two thermometers 0÷80 °C (on delivery of boiler circuit and mixed circuit), temperature sensor pocket (on delivery of mixed circuit), shut off valve (on return of boiler circuit), boiler circuit connections G 1”F (centre distance 200 mm) and mixed circuit connections G 1”M (centre distance 200 mm). Upper and lower parts made of nickel-plated CB753S brass; pipe made of nickel-plated half-hard copper; gaskets and O-rings made of peroxide-cured EPDM; other parts made of CW617N brass. Max operating temperature 100 °C. Max operating pressure 10 bar. Fixed point mixing 20÷60 °C by thermostatic control head with remote sensor T3011 included. Max differential pressure at mixing valve ends 250 mbar. Pump space 130 mm with G 1”1/2F flat seal connections.

EMCS compliant

.RVT .RFA

Distribuidor para calefacción y aire acondicionado

IVAR

Descargar
Mitsubishi Heavy Industries Air Conditioning Europe RAC-SKM20-35ZSP-W

RAC-SKM20-35ZSP-W

Wall mounted Standard Series - Indoor Unit - Elegant design that fits into any kind of interior decoration - Long reach airflow is achieved by using Jet Air technology (same technology as blade shape of jet engine) - Flap control system: flap can be set to wide angle position to provide a comfortable air flow - Cleaning and maintenance are easier than ever thanks to the removable cover - Two available ranges compatible with R32 (-W) or R410 (-S) and single / multi systems

Mitsubishi Heavy Industries Air Conditioning Europe

RAC-SKM20-35ZSP-W

Wall mounted Standard Series - Indoor Unit - Elegant design that fits into any kind of interior decoration - Long reach airflow is achieved by using Jet Air technology (same technology as blade shape of jet engine) - Flap control system: flap can be set to wide angle position to provide a comfortable air flow - Cleaning and maintenance are easier than ever thanks to the removable cover - Two available ranges compatible with R32 (-W) or R410 (-S) and single / multi systems

EMCS compliant

.DWG .RFA .IFC

Unidad de aire acondicionado

Mitsubishi Heavy Industries Air Conditioning Europe

Descargar
Mitsubishi Heavy Industries Air Conditioning Europe FDCR-KXE6

FDCR-KXE6

Refresh KX- Heat Pump VRF outdoor unit Refresh KX Heat Pump VRF outdoor unit 22.4 kW and 28.0 kW in cooling -Replacing a used unit with new one, applies to a wide range of pipe sizes (R22, R407C, R410A standard size). - These units can reuse existing piping Savings on replacement expenses such as scrapping waste material or procuring new pipe. -Possible to replace the existing unit with a new larger capacity unit. -Possible to replace plural systems with one system. For example: Existing 5HP x 2units can be replaced with a new 10HP x 1unit. -Wide range of controls, central controls and BMS systems are available.

Mitsubishi Heavy Industries Air Conditioning Europe

FDCR-KXE6

Refresh KX- Heat Pump VRF outdoor unit
Refresh KX Heat Pump VRF outdoor unit 22.4 kW and 28.0 kW in cooling
-Replacing a used unit with new one, applies to a wide range of pipe sizes (R22, R407C, R410A standard size).
- These units can reuse existing piping Savings on replacement expenses such as scrapping waste material or procuring new pipe.
-Possible to replace the existing unit with a new larger capacity unit.
-Possible to replace plural systems with one system. For example: Existing 5HP x 2units can be replaced with a new 10HP x 1unit.
-Wide range of controls, central controls and BMS systems are available.

EMCS compliant

.DWG .RFA .IFC

Bomba de calor

Mitsubishi Heavy Industries Air Conditioning Europe

Descargar
Mitsubishi Heavy Industries Air Conditioning Europe RAC-FDTC25-35VH1

RAC-FDTC25-35VH1

Ceiling Cassette 4way compact - Indoor Unit - New European compact design with flat panels that perfectly fit the standard ceiling (600 x 600) - Light and thin design, this product allows a very easy installation - Draft Prevention Panel (option) prevents cold/hot draft being blown directly on the user - Motion sensor (option): detects the presence/absence and human activity in a room to improve comfort and energy saving - Individual Flap Control System: four directions of air flow can be controlled individually - Compatible with R32 and R410A refrigerants and single / multi systems

Mitsubishi Heavy Industries Air Conditioning Europe

RAC-FDTC25-35VH1

Ceiling Cassette 4way compact - Indoor Unit
- New European compact design with flat panels that perfectly fit the standard ceiling (600 x 600)
- Light and thin design, this product allows a very easy installation
- Draft Prevention Panel (option) prevents cold/hot draft being blown directly on the user
- Motion sensor (option): detects the presence/absence and human activity in a room to improve comfort and energy saving
- Individual Flap Control System: four directions of air flow can be controlled individually
- Compatible with R32 and R410A refrigerants and single / multi systems

EMCS compliant

.DWG .RFA .IFC

Unidad de aire acondicionado

Mitsubishi Heavy Industries Air Conditioning Europe

Descargar
IVAR CI400NR - Modular manifold EASY LOCK series

CI400NR - Modular manifold EASY LOCK series

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves). Modular plain manifold EASY-LOCK series. Manifolds can be used to supply DHW. The body is made of brass CW617N nickel-plated only externally. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 100°C. Maximum operating pressure: 10 bar. Main connections: G 3/4"F or G 1"F. Secondary connections: EUROK or 1/2"M or 1/2"M TP (flat seal). Sizes available: from 2 to 4 ways.

IVAR

CI400NR - Modular manifold EASY LOCK series

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves). Modular plain manifold EASY-LOCK series. Manifolds can be used to supply DHW. The body is made of brass CW617N nickel-plated only externally. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 100°C. Maximum operating pressure: 10 bar. Main connections: G 3/4"F or G 1"F. Secondary connections: EUROK or 1/2"M or 1/2"M TP (flat seal). Sizes available: from 2 to 4 ways.

EMCS compliant

.RFA

Componentes para instalaciones de saneamiento y de alcantarillado

IVAR

Descargar
Mitsubishi Heavy Industries Air Conditioning Europe FDTW-KXE6F

FDTW-KXE6F

Ceiling Cassette-2way - Indoor Unit - According to room temperature conditions, four directions air flow can be controlled individually by flap control system. - Due to optimization of outlet design of air flow our new advanced technology, sufficient air flow is secured and long reach of air flow is achieved. - The flap can swing within the range of upper and lower flap position selected with wired remote control. - Transparent access hole to drain pan to check the drain pan without removing drain pan. - Standard built- in drain pump.

Mitsubishi Heavy Industries Air Conditioning Europe

FDTW-KXE6F

Ceiling Cassette-2way - Indoor Unit
- According to room temperature conditions, four directions air flow can be controlled individually by flap control system.
- Due to optimization of outlet design of air flow our new advanced technology, sufficient air flow is secured and long reach of air flow is achieved.
- The flap can swing within the range of upper and lower flap position selected with wired remote control.
- Transparent access hole to drain pan to check the drain pan without removing drain pan.
- Standard built- in drain pump.

EMCS compliant

.DWG .RFA .IFC

Unidad de aire acondicionado

Mitsubishi Heavy Industries Air Conditioning Europe

Descargar
Mitsubishi Heavy Industries Air Conditioning Europe PAC-FDTC40-60VH

PAC-FDTC40-60VH

Ceiling Cassette - 4way compact - Indoor unit - New European compact design with flat panels that perfectly fit the standard ceiling (600 x 600) - Light (14 kg) and thin (248 mm), this product allows a very easy installation - Draft Prevention Panel (option) prevents cold/hot draft being blown directly on the user - Individual Flap Control System: four directions of air flow can be controlled individually - Quiet operation by adopting new turbo fan and improving new heat exchanger enables noise reduction - Drain can be discharged upward by 850mm from the ceiling surface and allows high degree of freedom - Powerful blowout carries comfortable air flow and is well suited for high ceilings - Compatible with R410 and R32 refrigerants

Mitsubishi Heavy Industries Air Conditioning Europe

PAC-FDTC40-60VH

Ceiling Cassette - 4way compact - Indoor unit - New European compact design with flat panels that perfectly fit the standard ceiling (600 x 600) - Light (14 kg) and thin (248 mm), this product allows a very easy installation - Draft Prevention Panel (option) prevents cold/hot draft being blown directly on the user - Individual Flap Control System: four directions of air flow can be controlled individually - Quiet operation by adopting new turbo fan and improving new heat exchanger enables noise reduction - Drain can be discharged upward by 850mm from the ceiling surface and allows high degree of freedom - Powerful blowout carries comfortable air flow and is well suited for high ceilings - Compatible with R410 and R32 refrigerants

EMCS compliant

.DWG .RFA .IFC

Unidad de aire acondicionado

Mitsubishi Heavy Industries Air Conditioning Europe

Descargar
IVAR CI350N - Modular manifold EASY LOCK series

CI350N - Modular manifold EASY LOCK series

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves). Modular plain manifold EASY LOCK series. Manifolds can be used to supply DCW or DHW. The body is made of brass CW617N nickel-plated only externally. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 100°C. Maximum operating pressure: 10 bar. Main connections: G 3/4"F or G 1"F. Secondary connections: EUROK or 1/2"M or 1/2"M TP (flat seal). Sizes available: from 2 to 5 ways.

IVAR

CI350N - Modular manifold EASY LOCK series

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves). Modular plain manifold EASY LOCK series. Manifolds can be used to supply DCW or DHW. The body is made of brass CW617N nickel-plated only externally. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 100°C. Maximum operating pressure: 10 bar. Main connections: G 3/4"F or G 1"F. Secondary connections: EUROK or 1/2"M or 1/2"M TP (flat seal). Sizes available: from 2 to 5 ways.

EMCS compliant

.RFA

Componentes para instalaciones de saneamiento y de alcantarillado

IVAR

Descargar
Mitsubishi Heavy Industries Air Conditioning Europe PAC-FDC100-140VNA - VSA / -W

PAC-FDC100-140VNA - VSA / -W

Heat pump micro inverter - Outdoor unit - The Micro Inverter range offers products from 10 to 14 kW in cooling mode with high seasonal performance up to level A++ - Wide range of operation down to -20 C in heating and -15 C in cooling - Component technology contributing to environmental protection with a range operating with R32 (-W) and another with R410A - High efficiency performance and low vibration thanks to the use of DC twin rotary compressor technology - Equipped with a silent mode offering 6 dB less compared to standard operation - Design flexibility optimised with a compatible piping length up to 50 m and a precharged piping length of 30 m

Mitsubishi Heavy Industries Air Conditioning Europe

PAC-FDC100-140VNA - VSA / -W

Heat pump micro inverter - Outdoor unit
- The Micro Inverter range offers products from 10 to 14 kW in cooling mode with high seasonal performance up to level A++
- Wide range of operation down to -20 C in heating and -15 C in cooling
- Component technology contributing to environmental protection with a range operating with R32 (-W) and another with R410A
- High efficiency performance and low vibration thanks to the use of DC twin rotary compressor technology
- Equipped with a silent mode offering 6 dB less compared to standard operation
- Design flexibility optimised with a compatible piping length up to 50 m and a precharged piping length of 30 m

EMCS compliant

.DWG .RFA .IFC

Bomba de calor

Mitsubishi Heavy Industries Air Conditioning Europe

Descargar
IVAR PICV 200-205-210 With PICC 22

PICV 200-205-210 With PICC 22

Valve that keeps the flow rate constant during operation within a certain differential pressure range thanks to a membrane device with a contrast spring. Complete with two pockets G 1/4"F for piezometric sockets (IVAR AVB 10) and with plugs for piezometric sockets and cartridge. PICV 200 (female) connections: G 1"1/2F, G 2"F in compliance with ISO 228/1. PICV 205 (male - flat seal) connections: G 2"M, G 2"1/2M in compliance with ISO 228/1. PICV 210 (with unions) connections: G 1"1/2M, G 2"M in compliance with ISO 228/1 and EN 10226-1. To combine with PICC 22 cartridge. PICC connection: W81x16. Compatible with water or glycol solutions max 30%. Min operating temperature: -20 °C. Max operating temperature: 120 °C. Max operating pressure: 25 bar. Valve material: CW617N brass. Sealing gaskets material: Peroxide EPDM. IVAR PICC 22: 41 flow rate ranges to set even during operation; brass and PSU insert; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets.

IVAR

PICV 200-205-210 With PICC 22

Valve that keeps the flow rate constant during operation within a certain differential pressure range thanks to a membrane device with a contrast spring. Complete with two pockets G 1/4"F for piezometric sockets (IVAR AVB 10) and with plugs for piezometric sockets and cartridge. PICV 200 (female) connections: G 1"1/2F, G 2"F in compliance with ISO 228/1. PICV 205 (male - flat seal) connections: G 2"M, G 2"1/2M in compliance with ISO 228/1. PICV 210 (with unions) connections: G 1"1/2M, G 2"M in compliance with ISO 228/1 and EN 10226-1. To combine with PICC 22 cartridge. PICC connection: W81x16. Compatible with water or glycol solutions max 30%. Min operating temperature: -20 °C. Max operating temperature: 120 °C. Max operating pressure: 25 bar. Valve material: CW617N brass. Sealing gaskets material: Peroxide EPDM. IVAR PICC 22: 41 flow rate ranges to set even during operation; brass and PSU insert; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets.

EMCS compliant

.RFA

Válvula para calefacción y refrigeración

IVAR

Descargar
IVAR IVARSAT-HL-HLE

IVARSAT-HL-HLE

Satellite module that independently manages high-temperature and low-temperature heating (direct and mixed circuits) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; mixing valve for fixed point mixing (with thermostatic control head and remote contact probe) or outside compensated temperature mixing (with axial servomotor and control unit); three-speed pump / model “E” with variable-speed pump EEI<20; summer/winter two-way valve on high-temperature and low-temperature circuits; pocket for temperature immersion probe on delivery side of primary circuit; balancing valve on primary circuit; balancing by-pass valve on mixed circuit; balancing lockshield of heating/domestic water circuit; hydraulic separator with built-in check valve; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. High-temperature domestic water outlet. Hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor.

IVAR

IVARSAT-HL-HLE

Satellite module that independently manages high-temperature and low-temperature heating (direct and mixed circuits) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; mixing valve for fixed point mixing (with thermostatic control head and remote contact probe) or outside compensated temperature mixing (with axial servomotor and control unit); three-speed pump / model “E” with variable-speed pump EEI<20; summer/winter two-way valve on high-temperature and low-temperature circuits; pocket for temperature immersion probe on delivery side of primary circuit; balancing valve on primary circuit; balancing by-pass valve on mixed circuit; balancing lockshield of heating/domestic water circuit; hydraulic separator with built-in check valve; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. High-temperature domestic water outlet. Hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor.

EMCS compliant

.RFA

Distribuidor para calefacción y aire acondicionado

IVAR

Descargar
IVAR PICV 100-105-110 With PICC 11-12-13

PICV 100-105-110 With PICC 11-12-13

Valve that keeps the flow rate constant during operation within a certain differential pressure range thanks to a membrane device with a contrast spring. Complete with two pockets G 1/4"F for piezometric sockets (IVAR AVB 10) and with plugs for piezometric sockets and cartridge. PICV 100 (female) connections: G 1"F, G 1"1/4F in compliance with ISO 228/1. PICV 105 (male - flat seal) connections: G 1"M, G 1"1/4M, G 1"1/2M in compliance with ISO 228/1. PICV 110 (with unions) connections: G 3/4"M, G 1"M, G 1"1/4M in compliance with ISO 228/1 and EN 10226-1. To combine with PICC 11, PICC 12 or PICC 13 cartridges. PICC connection: M54x1.5. Compatible with water or glycol solutions max 30%. Min operating temperature: -20 °C. Max operating temperature: 120 °C. Max operating pressure: 25 bar. Max closing pressure with PICC 13: 4 bar. Valve material: CW617N brass. Sealing gaskets material: Peroxide EPDM. IVAR PICC 11: 8 flow rate ranges to set; brass and POM insert; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets. IVAR PICC 12: 41 flow rate ranges to set even during operation; brass and PSU insert; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets. IVAR PICC 13: 41 flow rate ranges to set even during operation; to combine with IVAR RV 03 axial motor (M30x1.5; 2 points/3 points 230 V AC or 2 points/3 points 24 V AC or proportional 0-10 V 24 V AC adjustment); max closing pressure 4 bar; brass and PSU/POM/PPS (glass-fibre reinforced) insert; stainless steel internal metal components; PPS/Peroxide EPDM cone; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets.

IVAR

PICV 100-105-110 With PICC 11-12-13

Valve that keeps the flow rate constant during operation within a certain differential pressure range thanks to a membrane device with a contrast spring. Complete with two pockets G 1/4"F for piezometric sockets (IVAR AVB 10) and with plugs for piezometric sockets and cartridge. PICV 100 (female) connections: G 1"F, G 1"1/4F in compliance with ISO 228/1. PICV 105 (male - flat seal) connections: G 1"M, G 1"1/4M, G 1"1/2M in compliance with ISO 228/1. PICV 110 (with unions) connections: G 3/4"M, G 1"M, G 1"1/4M in compliance with ISO 228/1 and EN 10226-1. To combine with PICC 11, PICC 12 or PICC 13 cartridges. PICC connection: M54x1.5. Compatible with water or glycol solutions max 30%. Min operating temperature: -20 °C. Max operating temperature: 120 °C. Max operating pressure: 25 bar. Max closing pressure with PICC 13: 4 bar. Valve material: CW617N brass. Sealing gaskets material: Peroxide EPDM. IVAR PICC 11: 8 flow rate ranges to set; brass and POM insert; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets. IVAR PICC 12: 41 flow rate ranges to set even during operation; brass and PSU insert; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets. IVAR PICC 13: 41 flow rate ranges to set even during operation; to combine with IVAR RV 03 axial motor (M30x1.5; 2 points/3 points 230 V AC or 2 points/3 points 24 V AC or proportional 0-10 V 24 V AC adjustment); max closing pressure 4 bar; brass and PSU/POM/PPS (glass-fibre reinforced) insert; stainless steel internal metal components; PPS/Peroxide EPDM cone; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets.

EMCS compliant

.RFA

Válvula para calefacción y refrigeración

IVAR

Descargar
IVAR CI400NB - Modular manifold EASY LOCK series

CI400NB - Modular manifold EASY LOCK series

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves). Modular plain manifold EASY-LOCK series. Manifolds can be used to supply DCW. The body is made of brass CW617N nickel-plated only externally. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 100°C. Maximum operating pressure: 10 bar. Main connections: G 3/4"F or G 1"F. Secondary connections: EUROK or 1/2"M or 1/2"M TP (flat seal). Sizes available: from 2 to 4 ways.

IVAR

CI400NB - Modular manifold EASY LOCK series

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves). Modular plain manifold EASY-LOCK series. Manifolds can be used to supply DCW. The body is made of brass CW617N nickel-plated only externally. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 100°C. Maximum operating pressure: 10 bar. Main connections: G 3/4"F or G 1"F. Secondary connections: EUROK or 1/2"M or 1/2"M TP (flat seal). Sizes available: from 2 to 4 ways.

EMCS compliant

.RFA

Componentes para instalaciones de saneamiento y de alcantarillado

IVAR

Descargar
IVAR CS200N - Modular plain manifold EASY LOCK series

CS200N - Modular plain manifold EASY LOCK series

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves). Modular plain manifold EASY-LOCK series. Manifolds can be used to supply DCW or DHW. The body is made of brass CW617N nickel-plated only externally. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 120°C. Maximum operating pressure: 10 bar. Main connections: G 3/4"F or G 1"F. Secondary connections: EUROK or 1/2"M or 1/2"M TP (flat seal). Sizes available: from 2 to 4 ways.

IVAR

CS200N - Modular plain manifold EASY LOCK series

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves). Modular plain manifold EASY-LOCK series. Manifolds can be used to supply DCW or DHW. The body is made of brass CW617N nickel-plated only externally. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 120°C. Maximum operating pressure: 10 bar. Main connections: G 3/4"F or G 1"F. Secondary connections: EUROK or 1/2"M or 1/2"M TP (flat seal). Sizes available: from 2 to 4 ways.

EMCS compliant

.RFA

Componentes para instalaciones de saneamiento y de alcantarillado

IVAR

Descargar
IVAR IVARSAT-H VNR

IVARSAT-H VNR

Satellite module that independently manages high-temperature heating (direct circuit) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; domestic water preheating device; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; summer/winter two-way valve; pocket for temperature immersion probe on delivery side of primary circuit; balancing lockshield of primary circuit with double micrometrical adjustment; balancing lockshield of heating/domestic water circuit; differential overpressure by-pass valve on primary circuit; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. Model “1” with high-temperature domestic water outlet. Model “R” with hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor. In compliance with Belgaqua.

IVAR

IVARSAT-H VNR

Satellite module that independently manages high-temperature heating (direct circuit) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; domestic water preheating device; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; summer/winter two-way valve; pocket for temperature immersion probe on delivery side of primary circuit; balancing lockshield of primary circuit with double micrometrical adjustment; balancing lockshield of heating/domestic water circuit; differential overpressure by-pass valve on primary circuit; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. Model “1” with high-temperature domestic water outlet. Model “R” with hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor. In compliance with Belgaqua.

EMCS compliant

.RFA

Distribuidor para calefacción y aire acondicionado

IVAR

Descargar
IVAR PICV 00-05-10 With PICC 01-02-03

PICV 00-05-10 With PICC 01-02-03

Valve that keeps the flow rate constant during operation within a certain differential pressure range thanks to a membrane device with a contrast spring. Complete with two pockets G 1/4"F for piezometric sockets (IVAR AVB 10) and with plugs for piezometric sockets and cartridge. PICV 00 (female) connections: G 1/2"F, G 3/4"F, G 1"F in compliance with ISO 228/1. PICV 05 (male - flat seal) connections: G 3/4"M, EUROK, G 1"M, G 1"1/4M in compliance with ISO 228/1. PICV 10 (with unions) connections: G 1/2"M, G 3/4"M, G 1"M in compliance with ISO 228/1 and EN 10226-1. To combine with PICC 01, PICC 02 or PICC 03 cartridges. PICC connection: M32x1.5. Compatible with water or glycol solutions max 30%. Min operating temperature: -20 °C. Max operating temperature: 120 °C. Max operating pressure: 25 bar. Max closing pressure with PICC 03: 6 bar. Valve material: CW617N brass. Sealing gaskets material: Peroxide EPDM. IVAR PICC 01: 8 flow rate ranges to set; brass and POM insert; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets. IVAR PICC 02: 41 flow rate ranges to set even during operation; brass and PSU insert; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets. IVAR PICC 03: 41 flow rate ranges to set even during operation; to combine with IVAR TE 3003 electrothermal actuator (M30x1.5; ON/OFF 230 V AC or ON/OFF 24 V AC or proportional 0-10 V 24 V AC adjustment) or IVAR RV 03 axial motor (M30x1.5; 2 points/3 points 230 V AC or 2 points/3 points 24 V AC or proportional 0-10 V 24 V AC adjustment); max closing pressure 6 bar; brass and PSU/POM/PPS (glass-fibre reinforced) insert; stainless steel internal metal components; PPS/Peroxide EPDM cone; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets.

IVAR

PICV 00-05-10 With PICC 01-02-03

Valve that keeps the flow rate constant during operation within a certain differential pressure range thanks to a membrane device with a contrast spring. Complete with two pockets G 1/4"F for piezometric sockets (IVAR AVB 10) and with plugs for piezometric sockets and cartridge. PICV 00 (female) connections: G 1/2"F, G 3/4"F, G 1"F in compliance with ISO 228/1. PICV 05 (male - flat seal) connections: G 3/4"M, EUROK, G 1"M, G 1"1/4M in compliance with ISO 228/1. PICV 10 (with unions) connections: G 1/2"M, G 3/4"M, G 1"M in compliance with ISO 228/1 and EN 10226-1. To combine with PICC 01, PICC 02 or PICC 03 cartridges. PICC connection: M32x1.5. Compatible with water or glycol solutions max 30%. Min operating temperature: -20 °C. Max operating temperature: 120 °C. Max operating pressure: 25 bar. Max closing pressure with PICC 03: 6 bar. Valve material: CW617N brass. Sealing gaskets material: Peroxide EPDM. IVAR PICC 01: 8 flow rate ranges to set; brass and POM insert; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets. IVAR PICC 02: 41 flow rate ranges to set even during operation; brass and PSU insert; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets. IVAR PICC 03: 41 flow rate ranges to set even during operation; to combine with IVAR TE 3003 electrothermal actuator (M30x1.5; ON/OFF 230 V AC or ON/OFF 24 V AC or proportional 0-10 V 24 V AC adjustment) or IVAR RV 03 axial motor (M30x1.5; 2 points/3 points 230 V AC or 2 points/3 points 24 V AC or proportional 0-10 V 24 V AC adjustment); max closing pressure 6 bar; brass and PSU/POM/PPS (glass-fibre reinforced) insert; stainless steel internal metal components; PPS/Peroxide EPDM cone; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets.

EMCS compliant

.RFA

Válvula para calefacción y refrigeración

IVAR

Descargar
IVAR COMBIMIX

COMBIMIX

Mixing and boosting unit IVAR COMBIMIX for radiant installations complete with two-way mixing valve, balancing valve (on the cold way), two shut-off ball valves for the pump, two fill/drain valves, two automatic air vent valves, three thermometers 0÷80 °C (on delivery and return of boiler circuit and on delivery of mixed circuit), temperature sensor pocket (on delivery of mixed circuit), shut-off valve (on return of boiler circuit), boiler circuit connections G 1”F (centre distance 200 mm) and mixed circuit connections G 1”M with swivelling nipples (centre distance 200 mm). Upper and lower parts made of nickel-plated CB753S brass; pipe made of nickel-plated half-hard copper; gaskets and O-rings made of peroxide-cured EPDM; other parts made of CW617N brass. Max operating temperature 100 °C. Max operating pressure 10 bar. Fixed point mixing 20÷60 °C by thermostatic control head with remote sensor T5011 included (max differential pressure at mixing valve ends 250 mbar) or set up for outside compensated temperature mixing by integrating axial servomotor IVAR RV 01 or thermoelectric actuator IVAR TE 3061. Differential bypass valve (optional) 0.2÷0.6 bar with half-hard nickel-plated pipe. Pump space 130 mm or 180 mm, G 1”1/2F flat seal connections. Equipped with variable-speed electronic pump WILO4F or variable-speed electronic pump WILO4F-180 or without pump. Accessories: high-temperature kit with pair of manifolds 1” x EUROK with shut-off and lockshield valves CEP/02 I – CEP/03 I (2 ways) – (3 ways), high-temperature kit with pair of simple manifolds 1” x EUROK CEP/02 – CEP/03 (2 ways) – (3 ways), insulation shell ACM 01, threaded spacer for pumps AC 633.

IVAR

COMBIMIX

Mixing and boosting unit IVAR COMBIMIX for radiant installations complete with two-way mixing valve, balancing valve (on the cold way), two shut-off ball valves for the pump, two fill/drain valves, two automatic air vent valves, three thermometers 0÷80 °C (on delivery and return of boiler circuit and on delivery of mixed circuit), temperature sensor pocket (on delivery of mixed circuit), shut-off valve (on return of boiler circuit), boiler circuit connections G 1”F (centre distance 200 mm) and mixed circuit connections G 1”M with swivelling nipples (centre distance 200 mm). Upper and lower parts made of nickel-plated CB753S brass; pipe made of nickel-plated half-hard copper; gaskets and O-rings made of peroxide-cured EPDM; other parts made of CW617N brass. Max operating temperature 100 °C. Max operating pressure 10 bar. Fixed point mixing 20÷60 °C by thermostatic control head with remote sensor T5011 included (max differential pressure at mixing valve ends 250 mbar) or set up for outside compensated temperature mixing by integrating axial servomotor IVAR RV 01 or thermoelectric actuator IVAR TE 3061. Differential bypass valve (optional) 0.2÷0.6 bar with half-hard nickel-plated pipe. Pump space 130 mm or 180 mm, G 1”1/2F flat seal connections. Equipped with variable-speed electronic pump WILO4F or variable-speed electronic pump WILO4F-180 or without pump. Accessories: high-temperature kit with pair of manifolds 1” x EUROK with shut-off and lockshield valves CEP/02 I – CEP/03 I (2 ways) – (3 ways), high-temperature kit with pair of simple manifolds 1” x EUROK CEP/02 – CEP/03 (2 ways) – (3 ways), insulation shell ACM 01, threaded spacer for pumps AC 633.

EMCS compliant

.RVT .RFA

Distribuidor para calefacción y aire acondicionado

IVAR

Descargar
IVAR IVARSAT-H

IVARSAT-H

Satellite module that independently manages high-temperature heating (direct circuit) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; domestic water preheating device; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; summer/winter two-way valve; pocket for temperature immersion probe on delivery side of primary circuit; balancing lockshield of primary circuit with double micrometrical adjustment; balancing lockshield of heating/domestic water circuit; differential overpressure by-pass valve on primary circuit; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. Model “1” with high-temperature domestic water outlet. Model “R” with hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor.

IVAR

IVARSAT-H

Satellite module that independently manages high-temperature heating (direct circuit) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; domestic water preheating device; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; summer/winter two-way valve; pocket for temperature immersion probe on delivery side of primary circuit; balancing lockshield of primary circuit with double micrometrical adjustment; balancing lockshield of heating/domestic water circuit; differential overpressure by-pass valve on primary circuit; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. Model “1” with high-temperature domestic water outlet. Model “R” with hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor.

EMCS compliant

.RFA

Distribuidor para calefacción y aire acondicionado

IVAR

Descargar
IVAR IVARSAT-L-LE

IVARSAT-L-LE

Satellite module that independently manages low-temperature heating (mixed circuit) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; mixing valve for fixed point mixing (with thermostatic control head and remote contact probe) or outside compensated temperature mixing (with axial servomotor and control unit); three-speed pump / model “E” with variable-speed pump EEI<20; summer/winter two-way valve; pocket for temperature immersion probe on delivery side of primary circuit; balancing valve on primary circuit; balancing by-pass valve on mixed circuit; balancing lockshield of heating/domestic water circuit; hydraulic separator with built-in check valve; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. Model “1” with high-temperature domestic water outlet. Model “R” with hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor.

IVAR

IVARSAT-L-LE

Satellite module that independently manages low-temperature heating (mixed circuit) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; mixing valve for fixed point mixing (with thermostatic control head and remote contact probe) or outside compensated temperature mixing (with axial servomotor and control unit); three-speed pump / model “E” with variable-speed pump EEI<20; summer/winter two-way valve; pocket for temperature immersion probe on delivery side of primary circuit; balancing valve on primary circuit; balancing by-pass valve on mixed circuit; balancing lockshield of heating/domestic water circuit; hydraulic separator with built-in check valve; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. Model “1” with high-temperature domestic water outlet. Model “R” with hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor.

EMCS compliant

.RFA

Distribuidor para calefacción y aire acondicionado

IVAR

Descargar
IVAR Fan-Coil Unit Kit

Fan-Coil Unit Kit

IVAR FCU-Kit: Pre-assembled brass multi-function bypass unit for fan-coil systems, chilled beams, heaters and other constant flow rate conditioning systems. Can be used for both heating and cooling. Consisting of: a pair of three-way valves for setting 5 different operating modes, a mesh filter, two loading/unloading taps, a Venturi orifice with a pair of piezometric sockets and a PICV flow regulator. Permissible differential pressure ranges and flow control range (for PICV): with PICC 03 cartridge (code 590123) 16- 200 kPa, 37-575 l/h; with PICC 03 cartridge (code 590124) 30-400 kPa, 64-1110 l/h. Mesh filter (500 μm) in stainless steel AISI 304. Connections to the primary circuit (with unions): 1/2 "F (DN 15) - 3/4 "F (DN 20). Connections to the secondary circuit: 1/2 "F (DN 15) - 3/4 "F (DN 20). Maximum operating pressure: 10 bar. Maximum operating temperature: 120 °C. Available with insulation shell in grey ARPRO 5135 FR with conductivity 0.037 W/mK, density 50 kg/m3, reaction to fire class HF-1 according to UL-94 standard.

IVAR

Fan-Coil Unit Kit

IVAR FCU-Kit: Pre-assembled brass multi-function bypass unit for fan-coil systems, chilled beams, heaters and other constant flow rate conditioning systems. Can be used for both heating and cooling. Consisting of: a pair of three-way valves for setting 5 different operating modes, a mesh filter, two loading/unloading taps, a Venturi orifice with a pair of piezometric sockets and a PICV flow regulator. Permissible differential pressure ranges and flow control range (for PICV): with PICC 03 cartridge (code 590123) 16- 200 kPa, 37-575 l/h; with PICC 03 cartridge (code 590124) 30-400 kPa, 64-1110 l/h. Mesh filter (500 μm) in stainless steel AISI 304. Connections to the primary circuit (with unions): 1/2 "F (DN 15) - 3/4 "F (DN 20). Connections to the secondary circuit: 1/2 "F (DN 15) - 3/4 "F (DN 20). Maximum operating pressure: 10 bar. Maximum operating temperature: 120 °C. Available with insulation shell in grey ARPRO 5135 FR with conductivity 0.037 W/mK, density 50 kg/m3, reaction to fire class HF-1 according to UL-94 standard.

EMCS compliant

.RVT .RFA

Unidad fan coil

IVAR

Descargar
IVAR EQCP1 Equicompact Metering Module

EQCP1 Equicompact Metering Module

IVAR EQCP1 (Kv 2.50): Two-way metering module for heating and cooling systems with DHW distribution lines and heat metering unit, equipped with template sockets instead of heat meters. Heat module consisting of CW617N brass monobloc with 2-way piston zone valve with M30×1.5 mm connection, selector balancing valve, filter, pocket for heat meter delivery sensor, M10×1 pressure pocket for dynamic balancing valve. Shut-off valves on the delivery and return to the boiler, on the delivery and return from the users, with slots for sealing. Drop pressure of the heat metering module Kv = 3.5. Placed on decomposable brackets and insulated with PP shell. Connections to the uprising columns and to the users of the G 3/4" heat module. Predisposition for heat meter with G 3/4" connections, length 110 mm and nominal flow rate Qnom = 1.5 m3/h. Domestic block with G 3/4" connections that can be intercepted with ball valves with sealing slots. Predisposition for insertion of DHW volumetric meters with G 3/4" connections, length 110 mm and nominal flow rate Qnom = 1.5 m3/h. Code 506587CB assembled in steel flush-mounted metal box with standard painted door, dimensions H 510 ×L 510 ×D 130 mm. Code 506587CL assembled in steel flush-mounted metal box with plasterable door, dimensions H 520 ×L 520 × D 130 mm. Max static operating pressure 10 bar; fluid temperature range 3÷90 ◦C. IVAR EQCP1 (Kv 3.00): Two-way metering module for heating and cooling systems with DHW distribution lines and heat metering unit, equipped with template sockets instead of heat meters. Heat module consisting of CW617N brass monobloc with 2-way piston zone valve with M30×1.5 mm connection, selector balancing valve, filter, pocket for heat meter delivery sensor, M10×1 pressure pocket for dynamic balancing valve. Shut-off valves on the delivery and return to the boiler, on the delivery and return from the users, with slots for sealing. Drop pressure of the heat metering module Kv = 3.5. Placed on decomposable brackets and insulated with PP shell. Connections to the uprising columns and to the users of the G 3/4" heat module. Predisposition for heat meter with G 3/4" connections, length 130 mm and nominal flow rate Qnom = 2.5 m3/h. Domestic block with G 3/4" connections that can be intercepted with ball valves with sealing slots. Predisposition for insertion of DHW volumetric meters with G 3/4" connections, length 110 mm and nominal flow rate Qnom = 1.5 m3/h. Code 506539CB assembled in steel flush-mounted metal box with standard painted door, dimensions H 510 ×L 510 ×D 130 mm. Code 506539CL assembled in steel flush-mounted metal box with plasterable door, dimensions H 520 ×L 520 × D 130 mm. Max static operating pressure 10 bar; fluid temperature range 3÷90 ◦C.

IVAR

EQCP1 Equicompact Metering Module

IVAR EQCP1 (Kv 2.50): Two-way metering module for heating and cooling systems with DHW distribution lines and heat metering unit, equipped with template sockets instead of heat meters. Heat module consisting of CW617N brass monobloc with 2-way piston zone valve with M30×1.5 mm connection, selector balancing valve, filter, pocket for heat meter delivery sensor, M10×1 pressure pocket for dynamic balancing valve. Shut-off valves on the delivery and return to the boiler, on the delivery and return from the users, with slots for sealing. Drop pressure of the heat metering module Kv = 3.5. Placed on decomposable brackets and insulated with PP shell. Connections to the uprising columns and to the users of the G 3/4" heat module. Predisposition for heat meter with G 3/4" connections, length 110 mm and nominal flow rate Qnom = 1.5 m3/h. Domestic block with G 3/4" connections that can be intercepted with ball valves with sealing slots. Predisposition for insertion of DHW volumetric meters with G 3/4" connections, length 110 mm and nominal flow rate Qnom = 1.5 m3/h. Code 506587CB assembled in steel flush-mounted metal box with standard painted door, dimensions H 510 ×L 510 ×D 130 mm. Code 506587CL assembled in steel flush-mounted metal box with plasterable door, dimensions H 520 ×L 520 × D 130 mm. Max static operating pressure 10 bar; fluid temperature range 3÷90 ◦C. IVAR EQCP1 (Kv 3.00): Two-way metering module for heating and cooling systems with DHW distribution lines and heat metering unit, equipped with template sockets instead of heat meters. Heat module consisting of CW617N brass monobloc with 2-way piston zone valve with M30×1.5 mm connection, selector balancing valve, filter, pocket for heat meter delivery sensor, M10×1 pressure pocket for dynamic balancing valve. Shut-off valves on the delivery and return to the boiler, on the delivery and return from the users, with slots for sealing. Drop pressure of the heat metering module Kv = 3.5. Placed on decomposable brackets and insulated with PP shell. Connections to the uprising columns and to the users of the G 3/4" heat module. Predisposition for heat meter with G 3/4" connections, length 130 mm and nominal flow rate Qnom = 2.5 m3/h. Domestic block with G 3/4" connections that can be intercepted with ball valves with sealing slots. Predisposition for insertion of DHW volumetric meters with G 3/4" connections, length 110 mm and nominal flow rate Qnom = 1.5 m3/h. Code 506539CB assembled in steel flush-mounted metal box with standard painted door, dimensions H 510 ×L 510 ×D 130 mm. Code 506539CL assembled in steel flush-mounted metal box with plasterable door, dimensions H 520 ×L 520 × D 130 mm. Max static operating pressure 10 bar; fluid temperature range 3÷90 ◦C.

EMCS compliant

.RVT .RFA

Unidad de control para calefacción y aire acondicionado

IVAR

Descargar
IVAR UNIMIX / UNIMIX-C

UNIMIX / UNIMIX-C

Mixing and pump units for radiant systems UNIMIX/UNIMIC-C modular with: UM 01 – UM 01D/S: regulation unit UNIMIX with/without pump complete with 3-way mixing valve with headwork for thermostatic control, secondary by-pass with double micrometric adjustment and position memory, primary by-pass for recirculation, thermomanometer 0÷120 °C 0÷6 bar for mixed water, thermometers 0÷80 °C for delivery and return waters, probe pocket for mixed water, shut-off ball valves G 1” secondary side and automatic air vent valve. Available with or without straight or angled shut-off ball valves G 3/4”F on primary side. Available with or without 3-speed standard pump WILO3F centre distance 130 mm or variable-speed electronic pump WILO4F centre distance 130 mm. Body made of nickel-plated CB753S brass; gaskets and O-rings made of peroxide-cured EPDM; other parts made of CW617N brass. Max operating temperature 100 °C. Max operating pressure 10 bar. Max differential pressure at mixing valve ends 250 mbar. UMC 01 – UMC 01D/S: regulation unit UNIMIX-C with/without pump complete with 3-way mixing valve with headwork for thermostatic control, secondary by-pass with double micrometric adjustment and position memory, primary by-pass for recirculation, thermometer 0÷80 °C for mixed water and probe pocket for mixed water. Available with or without straight or angled shut-off ball valves G 3/4”F on primary side. Available with or without 3-speed standard pump WILO3F centre distance 130 mm or variable-speed electronic pump WILO4F centre distance 130 mm. Body made of nickel-plated CB753S brass; gaskets and O-rings made of peroxide-cured EPDM; other parts made of CW617N brass. Max operating temperature 100 °C. Max operating pressure 10 bar. Max differential pressure at mixing valve ends 250 mbar. AUM 03: expanded polypropylene insulating cover. T 5011 U: thermostatic head with incorporated control and immersion remote sensor. Range 30÷55 °C o 25÷50 °C. Cable lengh 2 m. RV 01: axial servomotor M30x1.5. 3-point adjustment 230 V AC or proportional 0-10 V 24 V AC with display. AUM 01 - AUM 11 D/S: high-temperature kit for UNIMIX/UNIMIX-C with primary side connections G 1” and plain manifolds with 3 outlets (EUROK outlets). Complete with fill/drain valve and differential pressure by-pass valve 0.2÷0.6 bar. Available with or without straight or angled shut-off ball valves G 1” primary side. AUM 02 - AUM 12 D/S: high-temperature kit for UNIMIX/UNIMIX-C with primary side connections G 1” and manifolds with 3 outlets (delivery: double micrometric adjustment lockshield; return: headwork for thermostatic control with protection cap; EUROK outlets). Complete with fill/drain valve and differential pressure by-pass valve 0.2÷0.6 bar. Available with or without straight or angled shut-off ball valves G 1”F on primary side. AC 613 FU: fixed setting 60 °C safety thermostat pre-wired.

IVAR

UNIMIX / UNIMIX-C

Mixing and pump units for radiant systems UNIMIX/UNIMIC-C modular with: UM 01 – UM 01D/S: regulation unit UNIMIX with/without pump complete with 3-way mixing valve with headwork for thermostatic control, secondary by-pass with double micrometric adjustment and position memory, primary by-pass for recirculation, thermomanometer 0÷120 °C 0÷6 bar for mixed water, thermometers 0÷80 °C for delivery and return waters, probe pocket for mixed water, shut-off ball valves G 1” secondary side and automatic air vent valve. Available with or without straight or angled shut-off ball valves G 3/4”F on primary side. Available with or without 3-speed standard pump WILO3F centre distance 130 mm or variable-speed electronic pump WILO4F centre distance 130 mm. Body made of nickel-plated CB753S brass; gaskets and O-rings made of peroxide-cured EPDM; other parts made of CW617N brass. Max operating temperature 100 °C. Max operating pressure 10 bar. Max differential pressure at mixing valve ends 250 mbar. UMC 01 – UMC 01D/S: regulation unit UNIMIX-C with/without pump complete with 3-way mixing valve with headwork for thermostatic control, secondary by-pass with double micrometric adjustment and position memory, primary by-pass for recirculation, thermometer 0÷80 °C for mixed water and probe pocket for mixed water. Available with or without straight or angled shut-off ball valves G 3/4”F on primary side. Available with or without 3-speed standard pump WILO3F centre distance 130 mm or variable-speed electronic pump WILO4F centre distance 130 mm. Body made of nickel-plated CB753S brass; gaskets and O-rings made of peroxide-cured EPDM; other parts made of CW617N brass. Max operating temperature 100 °C. Max operating pressure 10 bar. Max differential pressure at mixing valve ends 250 mbar. AUM 03: expanded polypropylene insulating cover. T 5011 U: thermostatic head with incorporated control and immersion remote sensor. Range 30÷55 °C o 25÷50 °C. Cable lengh 2 m. RV 01: axial servomotor M30x1.5. 3-point adjustment 230 V AC or proportional 0-10 V 24 V AC with display. AUM 01 - AUM 11 D/S: high-temperature kit for UNIMIX/UNIMIX-C with primary side connections G 1” and plain manifolds with 3 outlets (EUROK outlets). Complete with fill/drain valve and differential pressure by-pass valve 0.2÷0.6 bar. Available with or without straight or angled shut-off ball valves G 1” primary side. AUM 02 - AUM 12 D/S: high-temperature kit for UNIMIX/UNIMIX-C with primary side connections G 1” and manifolds with 3 outlets (delivery: double micrometric adjustment lockshield; return: headwork for thermostatic control with protection cap; EUROK outlets). Complete with fill/drain valve and differential pressure by-pass valve 0.2÷0.6 bar. Available with or without straight or angled shut-off ball valves G 1”F on primary side. AC 613 FU: fixed setting 60 °C safety thermostat pre-wired.

EMCS compliant

.RVT .RFA

Unidad de control para calefacción y aire acondicionado

IVAR

Descargar
IVAR MULTIMIX

MULTIMIX

Distribution and mixing system IVAR MULTIMIX for thermal power stations, modular with: - Manifold made of CB753S brass from casting with adjustable and interceptable hydraulic separator integrated. Complete with union with swivel fittings G 1” for the connection to distribution kits, shut-off ball valves DN 25 at the inlets, thermomanometer 0-6 bar/0-120 ◦C and automatic air vent valve. 2-way or 3-way versions available. Possibility of connection to the primary circuit from above, below, right or left. Expandable by connecting to other manifolds with swivel nipples G 1”. Other components made of CW617N brass. Gaskets and o-rings made of Peroxide-cured EPDM. Connections to the primary circuit G 1”F, centre distance delivery/return 52 mm (inlet from the side), 197 mm (inlet from above or below, 2-way manifold), 170 mm (inlet from above or below, 3-way manifold); connections to the distribution circuits with swivel nut G 1”F, centre distance delivery/return 45 mm. Max operating temperature 120 ◦C. Max operating pressure 10 bar. Max primary circuit flow rate 3500 l/h. - High-temperature direct flow kit complete with telescopic system for pump connection, shut-off ball valves for pump connection, delivery and return thermometers 0÷80 ◦C; check valve. Primary circuit connections G 1” M, delivery/return centre distance 45 mm; distribution circuits connections G 3/4”F, delivery/return centre distance 90 mm. Parts from casting: CB753S brass. Other parts made of CW617N brass. Gaskets and o-rings: peroxide-cured EPDM. Max operating temperature (pump excluded) 120 ◦C. Max operating pressure 10 bar. - Low temperature mixing kit complete with 3-way mixing valve with headwork for thermostatic or motorisable control, secondary bypass with micrometric dually adjusted lockshields and position memory, telescopic system for pump connection, shut-off ball valves for pump connection, delivery and return thermometers 0÷80 ◦C, check valve, fixed setting safety thermostat 60◦C. Primary circuit connections (manifold-separator) G 1”M, centre distance delivery/return 45 mm; heating circuits connections G 3/4”F, centre distance delivery/return 90 mm. Parts from casting: CB753S brass. Other parts: CW617N brass. Gaskets and o-rings: peroxide-cured EPDM. Max operating temperature (pump excluded) 120 ◦C. Max operating pressure 10 bar. - Variable-speed electronic pump WILO4F centre distance 130 mm. - 3-speed standard pump WILO3F centre distance 130 mm. - Polypropylene insulation shell. - Wall fitted cabinet with variable height and depth. - T 5011 U: thermostatic head with incorporated control and immersion remote sensor. Connection: M30 x 1.5. Probe holder connection: 1/2". Range: 30-55 °C. Cable lenght: 2 m. - RV 01: axial motor. Connection: M30 x 1.5. 3-point adjustment 230 V AC or 24 V AC or proportional 0-10 V 24 V AC.

IVAR

MULTIMIX

Distribution and mixing system IVAR MULTIMIX for thermal power stations, modular with: - Manifold made of CB753S brass from casting with adjustable and interceptable hydraulic separator integrated. Complete with union with swivel fittings G 1” for the connection to distribution kits, shut-off ball valves DN 25 at the inlets, thermomanometer 0-6 bar/0-120 ◦C and automatic air vent valve. 2-way or 3-way versions available. Possibility of connection to the primary circuit from above, below, right or left. Expandable by connecting to other manifolds with swivel nipples G 1”. Other components made of CW617N brass. Gaskets and o-rings made of Peroxide-cured EPDM. Connections to the primary circuit G 1”F, centre distance delivery/return 52 mm (inlet from the side), 197 mm (inlet from above or below, 2-way manifold), 170 mm (inlet from above or below, 3-way manifold); connections to the distribution circuits with swivel nut G 1”F, centre distance delivery/return 45 mm. Max operating temperature 120 ◦C. Max operating pressure 10 bar. Max primary circuit flow rate 3500 l/h. - High-temperature direct flow kit complete with telescopic system for pump connection, shut-off ball valves for pump connection, delivery and return thermometers 0÷80 ◦C; check valve. Primary circuit connections G 1” M, delivery/return centre distance 45 mm; distribution circuits connections G 3/4”F, delivery/return centre distance 90 mm. Parts from casting: CB753S brass. Other parts made of CW617N brass. Gaskets and o-rings: peroxide-cured EPDM. Max operating temperature (pump excluded) 120 ◦C. Max operating pressure 10 bar. - Low temperature mixing kit complete with 3-way mixing valve with headwork for thermostatic or motorisable control, secondary bypass with micrometric dually adjusted lockshields and position memory, telescopic system for pump connection, shut-off ball valves for pump connection, delivery and return thermometers 0÷80 ◦C, check valve, fixed setting safety thermostat 60◦C. Primary circuit connections (manifold-separator) G 1”M, centre distance delivery/return 45 mm; heating circuits connections G 3/4”F, centre distance delivery/return 90 mm. Parts from casting: CB753S brass. Other parts: CW617N brass. Gaskets and o-rings: peroxide-cured EPDM. Max operating temperature (pump excluded) 120 ◦C. Max operating pressure 10 bar. - Variable-speed electronic pump WILO4F centre distance 130 mm. - 3-speed standard pump WILO3F centre distance 130 mm. - Polypropylene insulation shell. - Wall fitted cabinet with variable height and depth. - T 5011 U: thermostatic head with incorporated control and immersion remote sensor. Connection: M30 x 1.5. Probe holder connection: 1/2". Range: 30-55 °C. Cable lenght: 2 m. - RV 01: axial motor. Connection: M30 x 1.5. 3-point adjustment 230 V AC or 24 V AC or proportional 0-10 V 24 V AC.

EMCS compliant

.RVT .RFA

Distribuidor para calefacción y aire acondicionado

IVAR

Descargar