239 BIM collections found from 27 manufacturer(s) in United States Of America
RAMINEX TBE-STBA type 400

TBE-STBA type 400

Backflow protection unit TBE-STBA

RAMINEX

TBE-STBA type 400

Backflow protection unit TBE-STBA

Conforme a EMCS

.DWG .RFA .IFC

Valvola per uso meccanico

RAMINEX

Scarica
RAMINEX S1483

S1483

Three-Way Valve

RAMINEX

S1483

Three-Way Valve

Conforme a EMCS

.DWG .RFA .IFC

Valvola per uso meccanico

RAMINEX

Scarica
RAMINEX S588

S588

Ball Valve

RAMINEX

S588

Ball Valve

Conforme a EMCS

.DWG .RFA .IFC

Valvola per uso meccanico

RAMINEX

Scarica
RAMINEX S27

S27

Ball Valve

RAMINEX

S27

Ball Valve

Conforme a EMCS

.DWG .RFA .IFC

Valvola per uso meccanico

RAMINEX

Scarica
TTM Energiprodukter AB Airvent Lateral

Airvent Lateral

Valvola sfogo aria con scarico laterale

TTM Energiprodukter AB

Airvent Lateral

Valvola sfogo aria con scarico laterale

Conforme a EMCS

.DWG .RFA .IFC

Valvola per uso meccanico

TTM Energiprodukter AB

Scarica
TTM Energiprodukter AB SHUNTOMATIC V (Heating)

SHUNTOMATIC V (Heating)

Unità di circolazione / unità di derivazione / gruppo pompa, prefabbricato e pronto all'uso plug-and-play per applicazioni come radiatori, sistemi di ventilazione e riscaldamento a pavimento Temp. intervallo: +5 – +110 °C, max. pressione: 1,0 Mpa.

TTM Energiprodukter AB

SHUNTOMATIC V (Heating)

Unità di circolazione / unità di derivazione / gruppo pompa, prefabbricato e pronto all'uso plug-and-play per applicazioni come radiatori, sistemi di ventilazione e riscaldamento a pavimento Temp. intervallo: +5 – +110 °C, max. pressione: 1,0 Mpa.

Conforme a EMCS

.DWG .RFA .IFC

Valvola per uso meccanico

TTM Energiprodukter AB

Scarica
TTM Energiprodukter AB SHUNTOMATIC MINI SHUNT Unit

SHUNTOMATIC MINI SHUNT Unit

Gruppo di circolazione / gruppo di derivazione / gruppo pompa, prefabbricato e pronto all'uso per applicazioni come impianti a radiatori, ventilazione e riscaldamento a pavimento, con isolamento termico. Temp. intervallo: +5 – +110 °C, max. pressione: 1,0 Mpa.

TTM Energiprodukter AB

SHUNTOMATIC MINI SHUNT Unit

Gruppo di circolazione / gruppo di derivazione / gruppo pompa, prefabbricato e pronto all'uso per applicazioni come impianti a radiatori, ventilazione e riscaldamento a pavimento, con isolamento termico. Temp. intervallo: +5 – +110 °C, max. pressione: 1,0 Mpa.

Conforme a EMCS

.DWG .RFA .IFC

Valvola per uso meccanico

TTM Energiprodukter AB

Scarica
TTM Energiprodukter AB Airvent Automatic

Airvent Automatic

Valvola sfogo aria automatica diritta per alta pressione, attacco 1/2" F

TTM Energiprodukter AB

Airvent Automatic

Valvola sfogo aria automatica diritta per alta pressione, attacco 1/2" F

Conforme a EMCS

.DWG .RFA .IFC

Valvola per uso meccanico

TTM Energiprodukter AB

Scarica
TTM Energiprodukter AB SHUNTOMATIC K (Cooling)

SHUNTOMATIC K (Cooling)

Unità di circolazione/unità di derivazione/gruppo pompa, prefabbricato e pronto all'uso plug-and-play per applicazioni di raffreddamento come sistemi di ventilazione e raffreddamento a pavimento isolati con AF/Armaflex AF-2 di serie. Temp. intervallo: -20 – +80 °C, max. pressione: 1,0 Mpa.

TTM Energiprodukter AB

SHUNTOMATIC K (Cooling)

Unità di circolazione/unità di derivazione/gruppo pompa, prefabbricato e pronto all'uso plug-and-play per applicazioni di raffreddamento come sistemi di ventilazione e raffreddamento a pavimento isolati con AF/Armaflex AF-2 di serie. Temp. intervallo: -20 – +80 °C, max. pressione: 1,0 Mpa.

Conforme a EMCS

.DWG .RFA .IFC

Valvola per uso meccanico

TTM Energiprodukter AB

Scarica
Spirotech Unità di manutenzione per vaso di espansione

Unità di manutenzione per vaso di espansione

Unità di manutenzione per i vasi di espansione SpiroExpand

Spirotech

Unità di manutenzione per vaso di espansione

Unità di manutenzione per i vasi di espansione SpiroExpand

Conforme a EMCS

.DWG .RFA .IFC

Valvola per uso meccanico

Spirotech

Scarica
Henco BAP-FFV

BAP-FFV

Valvola a flusso totale in acciaio inossidabile - press x press

Henco

BAP-FFV

Valvola a flusso totale in acciaio inossidabile - press x press

Conforme a EMCS

.DWG .RFA .IFC

Valvola per uso meccanico

Henco

Scarica
Henco UFH-BMHT-VN

UFH-BMHT-VN

Gruppo valvola a sfera 90° B+R 1''x1'' con termometro - nichelato (incl. guarnizione)

Henco

UFH-BMHT-VN

Gruppo valvola a sfera 90° B+R 1''x1'' con termometro - nichelato (incl. guarnizione)

Conforme a EMCS

.DWG .RFA .IFC

Valvola per uso meccanico

Henco

Scarica
Henco UFH-BM-VN

UFH-BM-VN

Gruppo valvola a sfera B+ R - nichelato (incl. guarnizione) - 1''x1''

Henco

UFH-BM-VN

Gruppo valvola a sfera B+ R - nichelato (incl. guarnizione) - 1''x1''

Conforme a EMCS

.DWG .RFA .IFC

Valvola per uso meccanico

Henco

Scarica
Henco UFH-BMH-VN

UFH-BMH-VN

Gruppo valvola a sfera 90° B+R 1''x1'' - nichelato (incl. guarnizione)

Henco

UFH-BMH-VN

Gruppo valvola a sfera 90° B+R 1''x1'' - nichelato (incl. guarnizione)

Conforme a EMCS

.DWG .RFA .IFC

Valvola per uso meccanico

Henco

Scarica
Mitsubishi Heavy Industries Air Conditioning Europe MTH-Q4E-Q8E

MTH-Q4E-Q8E

3 way valve (for anti-freezing or recirculation loop control)

Mitsubishi Heavy Industries Air Conditioning Europe

MTH-Q4E-Q8E

3 way valve (for anti-freezing or recirculation loop control)

Conforme a EMCS

.DWG .RFA .IFC

Valvola per uso meccanico

Mitsubishi Heavy Industries Air Conditioning Europe

Scarica
Flamco Prescor IC 1/2 Fill

Prescor IC 1/2 Fill

Prescor IC Fill 15mm x 22mm - 8.0 Bar

Flamco

Prescor IC 1/2 Fill

Prescor IC Fill 15mm x 22mm - 8.0 Bar

Conforme a EMCS

.RFA

Valvola per uso meccanico

Flamco

Scarica
POLYMELT ECOSAN Slanted seat valve, body without discharge screw

ECOSAN Slanted seat valve, body without discharge screw

Slanted seat valve, body without discharge screw

POLYMELT

ECOSAN Slanted seat valve, body without discharge screw

Slanted seat valve, body without discharge screw

Conforme a EMCS

.DWG .RFA .IFC

Valvola per uso meccanico

POLYMELT

Scarica
POLYMELT ECOSAN Slanted seat valve, body with discharge screw

ECOSAN Slanted seat valve, body with discharge screw

Slanted seat valve, body with discharge screw

POLYMELT

ECOSAN Slanted seat valve, body with discharge screw

Slanted seat valve, body with discharge screw

Conforme a EMCS

.DWG .RFA .IFC

Valvola per uso meccanico

POLYMELT

Scarica
POLYMELT ECOSAN Shut-off valve, body without discharge screw

ECOSAN Shut-off valve, body without discharge screw

Shutt-off valve, body without discharge screw

POLYMELT

ECOSAN Shut-off valve, body without discharge screw

Shutt-off valve, body without discharge screw

Conforme a EMCS

.DWG .RFA .IFC

Valvola per uso meccanico

POLYMELT

Scarica
POLYMELT ECOSAN Shut-off valve, body with discharge screw

ECOSAN Shut-off valve, body with discharge screw

Shutt-off valve, body with discharge screw

POLYMELT

ECOSAN Shut-off valve, body with discharge screw

Shutt-off valve, body with discharge screw

Conforme a EMCS

.DWG .RFA .IFC

Valvola per uso meccanico

POLYMELT

Scarica
Caleffi FlowCal+ Compact

FlowCal+ Compact

Valvola di bilanciamento automatico

Caleffi

FlowCal+ Compact

Valvola di bilanciamento automatico

Conforme a EMCS

.DWG .RFA .IFC

Valvola per uso meccanico

Caleffi

Scarica
Caleffi 6000A Electronic mixing valve with programmable thermal disinfection

6000A Electronic mixing valve with programmable thermal disinfection

Valvola miscelatrice elettronica con disinfezione termica programmabile

Caleffi

6000A Electronic mixing valve with programmable thermal disinfection

Valvola miscelatrice elettronica con disinfezione termica programmabile

Conforme a EMCS

.DWG .RFA .IFC

Valvola per uso meccanico

Caleffi

Scarica
Pichler Lufttechnik BSK-R-M

BSK-R-M

Brandschutzklappe EI90S BSK-R-M-M10

Pichler Lufttechnik

BSK-R-M

Brandschutzklappe EI90S BSK-R-M-M10

Conforme a EMCS

.RFA

Valvola per la ventilazione

Pichler Lufttechnik

Scarica
Pichler Lufttechnik BSK-R-L

BSK-R-L

Brandschutzklappe EI90S BSK-R-L-M7

Pichler Lufttechnik

BSK-R-L

Brandschutzklappe EI90S BSK-R-L-M7

Conforme a EMCS

.RFA

Valvola per la ventilazione

Pichler Lufttechnik

Scarica
Pichler Lufttechnik BSK-E-M S

BSK-E-M S

Brandschutzklappe EI90S BSK-E-M-S

Pichler Lufttechnik

BSK-E-M S

Brandschutzklappe EI90S BSK-E-M-S

Conforme a EMCS

.RFA

Valvola per la ventilazione

Pichler Lufttechnik

Scarica
Pichler Lufttechnik BSK-E-M O3

BSK-E-M O3

Brandschutzklappe EI90S BSK-E-M-O3

Pichler Lufttechnik

BSK-E-M O3

Brandschutzklappe EI90S BSK-E-M-O3

Conforme a EMCS

.RFA

Valvola per la ventilazione

Pichler Lufttechnik

Scarica
Pichler Lufttechnik BSK-E-M O2

BSK-E-M O2

Brandschutzklappe EI90S BSK-E-M-O2

Pichler Lufttechnik

BSK-E-M O2

Brandschutzklappe EI90S BSK-E-M-O2

Conforme a EMCS

.RFA

Valvola per la ventilazione

Pichler Lufttechnik

Scarica
Pichler Lufttechnik BSK-E-M O1

BSK-E-M O1

Brandschutzklappe EI90S BSK-E-M-O1

Pichler Lufttechnik

BSK-E-M O1

Brandschutzklappe EI90S BSK-E-M-O1

Conforme a EMCS

.RFA

Valvola per la ventilazione

Pichler Lufttechnik

Scarica
Pichler Lufttechnik BSK-E-M M12

BSK-E-M M12

Brandschutzklappe EI90S BSK-E-M-M12

Pichler Lufttechnik

BSK-E-M M12

Brandschutzklappe EI90S BSK-E-M-M12

Conforme a EMCS

.RFA

Valvola per la ventilazione

Pichler Lufttechnik

Scarica
Pichler Lufttechnik BSK-E-M M11-M1

BSK-E-M M11-M1

Brandschutzklappe EI90S BSK-E-M-M1

Pichler Lufttechnik

BSK-E-M M11-M1

Brandschutzklappe EI90S BSK-E-M-M1

Conforme a EMCS

.RFA

Valvola per la ventilazione

Pichler Lufttechnik

Scarica
Pichler Lufttechnik BSK-E-L O3

BSK-E-L O3

Brandschutzklappe EI90S BSK-E-L-O3

Pichler Lufttechnik

BSK-E-L O3

Brandschutzklappe EI90S BSK-E-L-O3

Conforme a EMCS

.RFA

Valvola per la ventilazione

Pichler Lufttechnik

Scarica
Pichler Lufttechnik BSK-E-L O2

BSK-E-L O2

Brandschutzklappe EI90S BSK-E-L-O2

Pichler Lufttechnik

BSK-E-L O2

Brandschutzklappe EI90S BSK-E-L-O2

Conforme a EMCS

.RFA

Valvola per la ventilazione

Pichler Lufttechnik

Scarica
Pichler Lufttechnik BSK-E-L O1

BSK-E-L O1

Brandschutzklappe EI90S BSK-E-L-O1

Pichler Lufttechnik

BSK-E-L O1

Brandschutzklappe EI90S BSK-E-L-O1

Conforme a EMCS

.RFA

Valvola per la ventilazione

Pichler Lufttechnik

Scarica
Pichler Lufttechnik BSK-E-L M11

BSK-E-L M11

Brandschutzklappe EI90S BSK-E-L-M11

Pichler Lufttechnik

BSK-E-L M11

Brandschutzklappe EI90S BSK-E-L-M11

Conforme a EMCS

.RFA

Valvola per la ventilazione

Pichler Lufttechnik

Scarica
Pichler Lufttechnik BSK-E-L M9

BSK-E-L M9

Brandschutzklappe EI90S BSK-E-L-M9

Pichler Lufttechnik

BSK-E-L M9

Brandschutzklappe EI90S BSK-E-L-M9

Conforme a EMCS

.RFA

Valvola per la ventilazione

Pichler Lufttechnik

Scarica
Pichler Lufttechnik BSK-E-L M7

BSK-E-L M7

Brandschutzklappe EI90S BSK-E-L-M7

Pichler Lufttechnik

BSK-E-L M7

Brandschutzklappe EI90S BSK-E-L-M7

Conforme a EMCS

.RFA

Valvola per la ventilazione

Pichler Lufttechnik

Scarica
Pichler Lufttechnik BSK-E-M M9

BSK-E-M M9

Brandschutzklappe EI90S BSK-E-M-M9

Pichler Lufttechnik

BSK-E-M M9

Brandschutzklappe EI90S BSK-E-M-M9

Conforme a EMCS

.RFA

Valvola per la ventilazione

Pichler Lufttechnik

Scarica
Pichler Lufttechnik BSK-E-M M10

BSK-E-M M10

Brandschutzklappe EI90S BSK-E-M-M10

Pichler Lufttechnik

BSK-E-M M10

Brandschutzklappe EI90S BSK-E-M-M10

Conforme a EMCS

.RFA

Valvola per la ventilazione

Pichler Lufttechnik

Scarica
Pichler Lufttechnik BSK-E-LR

BSK-E-LR

Brandschutzklappe EI90S BSK-E-LR-S

Pichler Lufttechnik

BSK-E-LR

Brandschutzklappe EI90S BSK-E-LR-S

Conforme a EMCS

.RFA

Valvola per la ventilazione

Pichler Lufttechnik

Scarica
Pichler Lufttechnik BSK-E-M M8

BSK-E-M M8

Brandschutzklappe EI90S BSK-E-M-M8

Pichler Lufttechnik

BSK-E-M M8

Brandschutzklappe EI90S BSK-E-M-M8

Conforme a EMCS

.RFA

Valvola per la ventilazione

Pichler Lufttechnik

Scarica
Pichler Lufttechnik BSK-E-M M7

BSK-E-M M7

Brandschutzklappe EI90S BSK-E-M-M7

Pichler Lufttechnik

BSK-E-M M7

Brandschutzklappe EI90S BSK-E-M-M7

Conforme a EMCS

.RFA

Valvola per la ventilazione

Pichler Lufttechnik

Scarica
Pichler Lufttechnik BSK-E-L S

BSK-E-L S

Brandschutzklappe EI90S BSK-E-L-S

Pichler Lufttechnik

BSK-E-L S

Brandschutzklappe EI90S BSK-E-L-S

Conforme a EMCS

.RFA

Valvola per la ventilazione

Pichler Lufttechnik

Scarica
Caleffi 535H Pre-adjustable pressure reducing valve with or without pressure gauge

535H Pre-adjustable pressure reducing valve with or without pressure gauge

Pressure reducing valves are devices which, when installed on water systems, reduce and stabilize the pressure of the water entering from the water supply main. This pressure, in general, is too high and variable for domestic systems to operate correctly. The 535H series pressure reducing valves, ideal for residential and commercial applications, feature a dial indicator with direct readout allowing easy pressure pre-adjustment. After installation, the valve will control at the pre-adjusted pressure setting. The valve is constructed of DZR low-lead forged brass and incorporates a unique noise reducing and high flow seat design, is easily serviced with a replaceable cartridge and has an integral stainless steel filter (35 mesh), suitable for water systems that may contain sediment and debris. The valve is ICC-ES certified to ASSE 1003, CSA B356, NSF/ANSI/CAN 61 (180°F/82°C Commercial Hot), NSF 372, low lead laws and listed by ICC-ES. It meets codes IPC, IRC, UPC and NPC for use in accordance with the US and Canadian plumbing codes. Plenum rated: compliant with the requirements of standard UL 2043, without the outdoor protective cover.

Caleffi

535H Pre-adjustable pressure reducing valve with or without pressure gauge

Pressure reducing valves are devices which, when installed on water systems, reduce and stabilize the pressure of the water entering from the water supply main. This pressure, in general, is too high and variable for domestic systems to operate correctly. The 535H series pressure reducing valves, ideal for residential and commercial applications, feature a dial indicator with direct readout allowing easy pressure pre-adjustment. After installation, the valve will control at the pre-adjusted pressure setting. The valve is constructed of DZR low-lead forged brass and incorporates a unique noise reducing and high flow seat design, is easily serviced with a replaceable cartridge and has an integral stainless steel filter (35 mesh), suitable for water systems that may contain sediment and debris. The valve is ICC-ES certified to ASSE 1003, CSA B356, NSF/ANSI/CAN 61 (180°F/82°C Commercial Hot), NSF 372, low lead laws and listed by ICC-ES. It meets codes IPC, IRC, UPC and NPC for use in accordance with the US and Canadian plumbing codes. Plenum rated: compliant with the requirements of standard UL 2043, without the outdoor protective cover.

Conforme a EMCS

.DWG .RFA .IFC

Valvola per riscaldamento e raffreddamento

Caleffi

Scarica
Oventrop HydroControl V Double regulating and commissoning valves PN25

HydroControl V Double regulating and commissoning valves PN25

Balancing valve for the hydraulic balancing of distribution lines in central heating and cooling systems with closed circuits. Flow determination by differential pressure measurement taking into account the preset values, e.g. with the OV-DMC3 measuring system. Installation in flow or return. In an angled version with continuously controllable, infinitely fine presetting using a non-rising handwheel. Presetting is reproducible, lockable and sealable as standard. All functional elements on the handwheel side. Equipped with two measuring, draining and filling valves as standard. Valve housing and parts in contact with the medium made of dezincification-resistant brass, EPDM or PTFE. Maintenance-free, double spindle seal. Female thread on both sides according to EN 10226

Oventrop

HydroControl V Double regulating and commissoning valves PN25

Balancing valve for the hydraulic balancing of distribution lines in central heating and cooling systems with closed circuits. Flow determination by differential pressure measurement taking into account the preset values, e.g. with the OV-DMC3 measuring system. Installation in flow or return. In an angled version with continuously controllable, infinitely fine presetting using a non-rising handwheel. Presetting is reproducible, lockable and sealable as standard. All functional elements on the handwheel side. Equipped with two measuring, draining and filling valves as standard. Valve housing and parts in contact with the medium made of dezincification-resistant brass, EPDM or PTFE. Maintenance-free, double spindle seal. Female thread on both sides according to EN 10226

Conforme a EMCS

.DWG .RFA .IFC

Valvola per uso meccanico

Oventrop

Scarica
Oventrop AQH Dynamic thermostatic valve Straight Pattern

AQH Dynamic thermostatic valve Straight Pattern

Dynamic thermostatic valve AQH PN10 DN15 straight 35-420l

Oventrop

AQH Dynamic thermostatic valve Straight Pattern

Dynamic thermostatic valve AQH PN10 DN15 straight 35-420l

Conforme a EMCS

.DWG .RFA .IFC

Valvola per riscaldamento e raffreddamento

Oventrop

Scarica
Oventrop AQH Dynamic thermostatic valve Reversed Angle Pattern

AQH Dynamic thermostatic valve Reversed Angle Pattern

Dynamic thermostatic valve AQH PN10 DN15 axial 35-420l

Oventrop

AQH Dynamic thermostatic valve Reversed Angle Pattern

Dynamic thermostatic valve AQH PN10 DN15 axial 35-420l

Conforme a EMCS

.DWG .RFA .IFC

Valvola per riscaldamento e raffreddamento

Oventrop

Scarica
Oventrop AQH Dynamic thermostatic valve Angle Pattern

AQH Dynamic thermostatic valve Angle Pattern

Dynamic thermostatic valve AQH PN10 DN15 angle 35-420l

Oventrop

AQH Dynamic thermostatic valve Angle Pattern

Dynamic thermostatic valve AQH PN10 DN15 angle 35-420l

Conforme a EMCS

.DWG .RFA .IFC

Valvola per riscaldamento e raffreddamento

Oventrop

Scarica
Caleffi SinkMixer™ Scald Protection Point-of-Use Thermostatic Mixing Valve (4-way)

SinkMixer™ Scald Protection Point-of-Use Thermostatic Mixing Valve (4-way)

High performance; easy-to-install.The Caleffi SinkMixer™ 5212 scald protection undersink thermostatic mixing valve is precision engineered to deliver safe tempered water. Patent pending forged low-lead brass valve body enables high flow capacity in a very compact body. The easy-to-install 4-port design connects all water lines and, compared to standard 3-port valves, requires less piping and no tee. ICC-ES certified compliance to NSF/ANSI/CAN 61-2019 and IPC, IRC, UPC and NPC for drinking water systems in accordance with the U.S. and Canadian plumbing codes.

Caleffi

SinkMixer™ Scald Protection Point-of-Use Thermostatic Mixing Valve (4-way)

High performance; easy-to-install.The Caleffi SinkMixer™ 5212 scald protection undersink thermostatic mixing valve is precision engineered to deliver safe tempered water. Patent pending forged low-lead brass valve body enables high flow capacity in a very compact body. The easy-to-install 4-port design connects all water lines and, compared to standard 3-port valves, requires less piping and no tee. ICC-ES certified compliance to NSF/ANSI/CAN 61-2019 and IPC, IRC, UPC and NPC for drinking water systems in accordance with the U.S. and Canadian plumbing codes.

Conforme a EMCS

.DWG .RFA .IFC

Valvola per uso meccanico

Caleffi

Scarica
Caleffi SinkMixer™ Scald Protection Point-of-Use Thermostatic Mixing Valve (3-way)

SinkMixer™ Scald Protection Point-of-Use Thermostatic Mixing Valve (3-way)

High performance; easy-to-install.The Caleffi SinkMixer™ 5212 scald protection undersink thermostatic mixing valve is precision engineered to deliver safe tempered water. Patent pending forged low-lead brass valve body enables high flow capacity in a very compact body. The easy-to-install 4-port design connects all water lines and, compared to standard 3-port valves, requires less piping and no tee. ICC-ES certified compliance to NSF/ANSI/CAN 61-2019 and IPC, IRC, UPC and NPC for drinking water systems in accordance with the U.S. and Canadian plumbing codes. The 5212AP product includes compression union connections with plug for cold water outlet and copper compression fittings kit for hard piping installations.

Caleffi

SinkMixer™ Scald Protection Point-of-Use Thermostatic Mixing Valve (3-way)

High performance; easy-to-install.The Caleffi SinkMixer™ 5212 scald protection undersink thermostatic mixing valve is precision engineered to deliver safe tempered water. Patent pending forged low-lead brass valve body enables high flow capacity in a very compact body. The easy-to-install 4-port design connects all water lines and, compared to standard 3-port valves, requires less piping and no tee. ICC-ES certified compliance to NSF/ANSI/CAN 61-2019 and IPC, IRC, UPC and NPC for drinking water systems in accordance with the U.S. and Canadian plumbing codes. The 5212AP product includes compression union connections with plug for cold water outlet and copper compression fittings kit for hard piping installations.

Conforme a EMCS

.DWG .RFA .IFC

Valvola per uso meccanico

Caleffi

Scarica
Caleffi Compact pressure reducing valve without pressure gauge

Compact pressure reducing valve without pressure gauge

The PresCal™ Compact 533H series pressure reducing valve, ideal for small system applications, is constructed of a DZR low-lead forged brass body and incorporates a unique noise reducing and high flow seat design. It is easily serviced with a replaceable cartridge and has an integral stainless steel filter (35 mesh), helpful for water systems that may contain sediment or debris. A tamper-resistant cap is included to replace the standard cap to hide the adjustment screw to help prevent set point tampering.The valve complies with NSF/ANSI 61 (180°F/82°C Commercial Hot) as certified by ICC-ES, and complies with NSF/ANSI 372, low lead, and codes IPC, IRC, NPC and UPC for use in accordance with the US and Canadian plumbing codes, as certified by ICC-ES.

Caleffi

Compact pressure reducing valve without pressure gauge

The PresCal™ Compact 533H series pressure reducing valve, ideal for small system applications, is constructed of a DZR low-lead forged brass body and incorporates a unique noise reducing and high flow seat design. It is easily serviced with a replaceable cartridge and has an integral stainless steel filter (35 mesh), helpful for water systems that may contain sediment or debris. A tamper-resistant cap is included to replace the standard cap to hide the adjustment screw to help prevent set point tampering.The valve complies with NSF/ANSI 61 (180°F/82°C Commercial Hot) as certified by ICC-ES, and complies with NSF/ANSI 372, low lead, and codes IPC, IRC, NPC and UPC for use in accordance with the US and Canadian plumbing codes, as certified by ICC-ES.

Conforme a EMCS

.DWG .RFA .IFC

Valvola per uso meccanico

Caleffi

Scarica
Caleffi QuickSetter+™ Balancing Valve

QuickSetter+™ Balancing Valve

The QuickSetter+™ manual balancing valve contains a built-in flow meter and sight gauge, negating the need for differential pressure gauges and reference charts. Circuit balancing is fast, easy and accurate. Constructed of DZR low-lead brass, QuickSetter+ is ideally suited for use in plumbing applications such as hot water recirculation systems. The built-in check valve protects against circuit thermo-siphoning. The outlet dual-scale temperature gauge (optional) verifies the fluid temperature in the circuit. The flow meter sight gauge is dry (not exposed to the fluid) thus eliminating the possibility of gauge clouding/scaling over time. The QuickSetter+ can also be used in heating systems. Peroxide-cured EPDM seals provide chlorine and chloramine resistance and long operating life.

Caleffi

QuickSetter+™ Balancing Valve

The QuickSetter+™ manual balancing valve contains a built-in flow meter and sight gauge, negating the need for differential pressure gauges and reference charts. Circuit balancing is fast, easy and accurate. Constructed of DZR low-lead brass, QuickSetter+ is ideally suited for use in plumbing applications such as hot water recirculation systems. The built-in check valve protects against circuit thermo-siphoning. The outlet dual-scale temperature gauge (optional) verifies the fluid temperature in the circuit. The flow meter sight gauge is dry (not exposed to the fluid) thus eliminating the possibility of gauge clouding/scaling over time. The QuickSetter+ can also be used in heating systems. Peroxide-cured EPDM seals provide chlorine and chloramine resistance and long operating life.

Conforme a EMCS

.DWG .RFA .IFC

Valvola per uso meccanico

Caleffi

Scarica
Caleffi Adjustable Thermostatic and Pressure Balanced Mixing Valve

Adjustable Thermostatic and Pressure Balanced Mixing Valve

Stable mixed temperature performance with durable construction for long life. Due to the unique mixing chamber design, Caleffi MixCal™ produces very stable mixed water temperature as inlet temperatures and pressures vary. Scale formation is minimized via sliding surfaces constructed of an anti-scale polymer, thus guarding against seizing or erratic mixed temperatures. O-ring seals made from durable peroxide-cured EPDM resist wear from common water treatment additives such as chlorine and chloramines.

Caleffi

Adjustable Thermostatic and Pressure Balanced Mixing Valve

Stable mixed temperature performance with durable construction for long life. Due to the unique mixing chamber design, Caleffi MixCal™ produces very stable mixed water temperature as inlet temperatures and pressures vary. Scale formation is minimized via sliding surfaces constructed of an anti-scale polymer, thus guarding against seizing or erratic mixed temperatures. O-ring seals made from durable peroxide-cured EPDM resist wear from common water treatment additives such as chlorine and chloramines.

Conforme a EMCS

.DWG .RFA .IFC

Valvola per uso meccanico

Caleffi

Scarica
Caleffi PresCal™ 535H series Pressure Reducing Valve

PresCal™ 535H series Pressure Reducing Valve

High flow and quiet pressure control, The Caleffi PresCal™ 535H pressure reducing valve is precision engineered to deliver accurate pressure regulation under varying pressure and draw conditions. Low internal pressure losses produce superior falloff performance enabling more flow capacity to fixtures. NSF/ANSI/CAN 61 compliance, superior 180°F temperature rating, anti-scale components and convenient cartridge design add to the many features of this versatile and dependable PRV. UV Outdoor protective cover included for non-freezing outdoor installations.Pressure reducing valves are devices which, when installed on water systems, reduce and stabilize the pressure of the water entering from the water supply main. This pressure, in general, is too high and variable for domestic systems to operate correctly.The 535H series pressure reducing valves, ideal for residential and commercial applications, feature a dial indicator with direct readout allowing easy pressure pre-adjustment. After installation, the valve will control at the pre-adjusted pressure setting.The valve is constructed of DZR low-lead forged brass and incorporates a unique noise reducing and high flow seat design, is easily serviced with a replaceable cartridge and has an integral stainless steel filter (35 mesh), suitable for water systems that may contain sediment and debris.The valve is ICC-ES certified to ASSE 1003, CSA B356, NSF/ANSI/CAN 61 (180°F/82°C Commercial Hot), NSF 372, low lead laws and listed by ICC-ES. It meets codes IPC, IRC, UPC and NPC for use in accordance with the US and Canadian plumbing codes. Plenum rated: compliant with the requirements of standard UL 2043, without the outdoor protective cover.

Caleffi

PresCal™ 535H series Pressure Reducing Valve

High flow and quiet pressure control, The Caleffi PresCal™ 535H pressure reducing valve is precision engineered to deliver accurate pressure regulation under varying pressure and draw conditions. Low internal pressure losses produce superior falloff performance enabling more flow capacity to fixtures. NSF/ANSI/CAN 61 compliance, superior 180°F temperature rating, anti-scale components and convenient cartridge design add to the many features of this versatile and dependable PRV. UV Outdoor protective cover included for non-freezing outdoor installations.Pressure reducing valves are devices which, when installed on water systems, reduce and stabilize the pressure of the water entering from the water supply main. This pressure, in general, is too high and variable for domestic systems to operate correctly.The 535H series pressure reducing valves, ideal for residential and commercial applications, feature a dial indicator with direct readout allowing easy pressure pre-adjustment. After installation, the valve will control at the pre-adjusted pressure setting.The valve is constructed of DZR low-lead forged brass and incorporates a unique noise reducing and high flow seat design, is easily serviced with a replaceable cartridge and has an integral stainless steel filter (35 mesh), suitable for water systems that may contain sediment and debris.The valve is ICC-ES certified to ASSE 1003, CSA B356, NSF/ANSI/CAN 61 (180°F/82°C Commercial Hot), NSF 372, low lead laws and listed by ICC-ES. It meets codes IPC, IRC, UPC and NPC for use in accordance with the US and Canadian plumbing codes. Plenum rated: compliant with the requirements of standard UL 2043, without the outdoor protective cover.

Conforme a EMCS

.DWG .RFA .IFC

Valvola per riscaldamento e raffreddamento

Caleffi

Scarica
Oventrop Automatic thermostatic valve straight AQ without filter

Automatic thermostatic valve straight AQ without filter

Automatic thermostatic valve straight AQ without filter

Oventrop

Automatic thermostatic valve straight AQ without filter

Automatic thermostatic valve straight AQ without filter

Conforme a EMCS

.DWG .RFA .IFC

Valvola per riscaldamento e raffreddamento

Oventrop

Scarica
Oventrop Automatic thermostatic valve reversed angle AQ without filter

Automatic thermostatic valve reversed angle AQ without filter

Automatic thermostatic valve reversed angle AQ without filter

Oventrop

Automatic thermostatic valve reversed angle AQ without filter

Automatic thermostatic valve reversed angle AQ without filter

Conforme a EMCS

.DWG .RFA .IFC

Valvola per riscaldamento e raffreddamento

Oventrop

Scarica
Oventrop Automatic thermostatic valve angle AQ without filter

Automatic thermostatic valve angle AQ without filter

Automatic thermostatic valve angle AQ without filter

Oventrop

Automatic thermostatic valve angle AQ without filter

Automatic thermostatic valve angle AQ without filter

Conforme a EMCS

.DWG .RFA .IFC

Valvola per riscaldamento e raffreddamento

Oventrop

Scarica
Oventrop Automatic thermostatic valve straight AQ with filter

Automatic thermostatic valve straight AQ with filter

Automatic thermostatic valve straight AQ with filter

Oventrop

Automatic thermostatic valve straight AQ with filter

Automatic thermostatic valve straight AQ with filter

Conforme a EMCS

.DWG .RFA .IFC

Valvola per riscaldamento e raffreddamento

Oventrop

Scarica
Oventrop Automatic thermostatic valve reversed angle AQ with filter

Automatic thermostatic valve reversed angle AQ with filter

Automatic thermostatic valve reversed angle AQ with filter

Oventrop

Automatic thermostatic valve reversed angle AQ with filter

Automatic thermostatic valve reversed angle AQ with filter

Conforme a EMCS

.DWG .RFA .IFC

Valvola per riscaldamento e raffreddamento

Oventrop

Scarica
Oventrop Automatic thermostatic valve angle AQ with filter

Automatic thermostatic valve angle AQ with filter

Automatic thermostatic valve angle AQ with filter

Oventrop

Automatic thermostatic valve angle AQ with filter

Automatic thermostatic valve angle AQ with filter

Conforme a EMCS

.DWG .RFA .IFC

Valvola per riscaldamento e raffreddamento

Oventrop

Scarica
Oventrop Tri-CTR

Tri-CTR

Three-way diverting and mixing valve

Oventrop

Tri-CTR

Three-way diverting and mixing valve

Conforme a EMCS

.DWG .RFA .IFC

Valvola per uso meccanico

Oventrop

Scarica
Oventrop Valve Disc with FKM Seal

Valve Disc with FKM Seal

Bronze piston type spring assisted check valve

Oventrop

Valve Disc with FKM Seal

Bronze piston type spring assisted check valve

Conforme a EMCS

.DWG .RFA .IFC

Valvola per uso meccanico

Oventrop

Scarica
IVAR RTV Thermostatic Valve For Recirculation Branch Balancing

RTV Thermostatic Valve For Recirculation Branch Balancing

IVAR RTV: valvola termostatica per il controllo della temperatura dell'acqua nei rami di ricircolo. Inserto termostatico di bilanciamento con regolazione a punto fisso impostabile con manopola graduata munita di meccanismo di bloccaggio. Versione A con solo bilanciamento del ramo di ricircolo. Versione B con ciclo di disinfezione termica azionato a controllo termostatico. Versione C con ciclo di disinfezione termica azionato elettronicamente. Connessioni:1/2" F o 3/4"F. Range di regolazione 35-60 °C. ΔP massima ai capi della valvola 1 bar. Materiale principale: ottone CW617N. Manopola di regolazione: ABS. Oring di tenuta: EPDM perossidico.

IVAR

RTV Thermostatic Valve For Recirculation Branch Balancing

IVAR RTV: valvola termostatica per il controllo della temperatura dell'acqua nei rami di ricircolo. Inserto termostatico di bilanciamento con regolazione a punto fisso impostabile con manopola graduata munita di meccanismo di bloccaggio. Versione A con solo bilanciamento del ramo di ricircolo. Versione B con ciclo di disinfezione termica azionato a controllo termostatico. Versione C con ciclo di disinfezione termica azionato elettronicamente. Connessioni:1/2" F o 3/4"F. Range di regolazione 35-60 °C. ΔP massima ai capi della valvola 1 bar. Materiale principale: ottone CW617N. Manopola di regolazione: ABS. Oring di tenuta: EPDM perossidico.

Conforme a EMCS

.RVT .RFA

Valvola per riscaldamento e raffreddamento

IVAR

Scarica
Oventrop Optibal W6

Optibal W6

6-way ball valve G3/4

Oventrop

Optibal W6

6-way ball valve G3/4

Conforme a EMCS

.DWG .RFA .IFC

Valvola per uso meccanico

Oventrop

Scarica
Oventrop Optibal W6 with Actuator

Optibal W6 with Actuator

6-way ball valve G3/4

Oventrop

Optibal W6 with Actuator

6-way ball valve G3/4

Conforme a EMCS

.DWG .RFA .IFC

Valvola per uso meccanico

Oventrop

Scarica
Oventrop Aktor R ST L

Aktor R ST L

Electromotive rotary actuator “Aktor R ST L”, 24 V, steady control 0-10 V, or 0-24 V as 2 point control

Oventrop

Aktor R ST L

Electromotive rotary actuator “Aktor R ST L”, 24 V, steady control 0-10 V, or 0-24 V as 2 point control

Conforme a EMCS

.DWG .RFA .IFC

Valvola per uso meccanico

Oventrop

Scarica
Henco Henco Sprinkler

Henco Sprinkler

Sprinkler concealed cup with fixation

Henco

Henco Sprinkler

Sprinkler concealed cup with fixation

Conforme a EMCS

.RFA

Valvola per Sprinkler

Henco

Scarica
Sauter B2KL 6-way ball valve

B2KL 6-way ball valve

B2KL 6-way ball valve

Sauter

B2KL 6-way ball valve

B2KL 6-way ball valve

Conforme a EMCS

.DWG .RFA .IFC

Valvola per uso meccanico

Sauter

Scarica
Siegenia AEROTUBE DD 110

AEROTUBE DD 110

AEROTUBE DD 110: Passive ventilator for air supply or extraction

Siegenia

AEROTUBE DD 110

AEROTUBE DD 110: Passive ventilator for air supply or extraction

Conforme a EMCS

.DWG .RFA .IFC

Valvola per la ventilazione

Siegenia

Scarica
Siegenia AEROTUBE AZ SMART

AEROTUBE AZ SMART

AEROTUBE AZ smart: Can be used as an air supply or air extraction unit

Siegenia

AEROTUBE AZ SMART

AEROTUBE AZ smart: Can be used as an air supply or air extraction unit

Conforme a EMCS

.DWG .RFA .IFC

Valvola per la ventilazione

Siegenia

Scarica
Raccorderie Metalliche Spa inoxPRES 195 000

inoxPRES 195 000

Stopvalve with press ends

Raccorderie Metalliche Spa

inoxPRES 195 000

Stopvalve with press ends

Conforme a EMCS

.RFA

Valvola per uso meccanico

Raccorderie Metalliche Spa

Scarica
Raccorderie Metalliche Spa inoxPRES 195 004

inoxPRES 195 004

Non-return valve

Raccorderie Metalliche Spa

inoxPRES 195 004

Non-return valve

Conforme a EMCS

.RFA

Valvola per uso meccanico

Raccorderie Metalliche Spa

Scarica
IVAR PICV 00-05-10 With PICC 01-02-03

PICV 00-05-10 With PICC 01-02-03

Valvola che mantiene costante la portata entro un certo range di pressione differenziale grazie ad un dispositivo a membrana con molla di contrasto. Fornita con due sedi G 1/4"F per prese piezometriche (IVAR AVB 10) e con tappi per sedi prese piezometriche e cartuccia. Connessioni PICV 00 (femmina): G 1/2"F, G 3/4"F, G 1"F conformi ISO 228/1. Connessioni PICV 05 (maschio tenuta piana): G 3/4"M, EUROK, G 1"M, G 1"1/4M conformi ISO 228/1. Connessioni PICV 10 (con bocchettoni): G 1/2"M, G 3/4"M, G 1"M conformi ISO 228/1 ed EN 10226-1. Da combinare a cartucce: PICC 01, PICC 02, PICC 03. Connessione per PICC: M32x1.5. Compatibile con acqua o soluzioni glicolate max 30%. Temperatura operativa min: -20 °C. Temperatura operativa max: 120 °C. Pressione operativa max: 25 bar. Pressione di chiusura max con PICC 03: 6 bar. Materiale valvola: ottone CW617N. Materiale guarnizioni: EPDM perossidico. IVAR PICC 01: 8 range di portata selezionabili; inserto in ottone e POM; diaframma in HNBR/EPDM perossidico; guarnizioni in EPDM perossidico. IVAR PICC 02: 41 range di portata selezionabili anche ad impianto funzionante; inserto in ottone e PSU; diaframma in HNBR/EPDM perossidico; guarnizioni in EPDM perossidico. IVAR PICC 03: 41 range di portata selezionabili anche ad impianto funzionante; da combinare ad attuatore termoelettrico IVAR TE 3003 (M30x1.5; regolazione ON/OFF 230 V AC o ON/OFF 24 V AC o proporzionale 0-10 V 24 V AC) o a servomotore assiale IVAR RV 03 (M30x1.5; regolazione 2 punti/3 punti 230 V AC o 2 punti/3 punti 24 V AC o proporzionale 0-10 V 24 V AC); pressione in chiusura max 6 bar; inserto in ottone e PSU/POM/PPS rinforzato con fibre di vetro; componenti metallici interni in acciaio inox; cono in PPS/EPDM perossidico; diaframma in HNBR/EPDM perossidico; guarnizioni in EPDM perossidico.

IVAR

PICV 00-05-10 With PICC 01-02-03

Valvola che mantiene costante la portata entro un certo range di pressione differenziale grazie ad un dispositivo a membrana con molla di contrasto. Fornita con due sedi G 1/4"F per prese piezometriche (IVAR AVB 10) e con tappi per sedi prese piezometriche e cartuccia. Connessioni PICV 00 (femmina): G 1/2"F, G 3/4"F, G 1"F conformi ISO 228/1. Connessioni PICV 05 (maschio tenuta piana): G 3/4"M, EUROK, G 1"M, G 1"1/4M conformi ISO 228/1. Connessioni PICV 10 (con bocchettoni): G 1/2"M, G 3/4"M, G 1"M conformi ISO 228/1 ed EN 10226-1. Da combinare a cartucce: PICC 01, PICC 02, PICC 03. Connessione per PICC: M32x1.5. Compatibile con acqua o soluzioni glicolate max 30%. Temperatura operativa min: -20 °C. Temperatura operativa max: 120 °C. Pressione operativa max: 25 bar. Pressione di chiusura max con PICC 03: 6 bar. Materiale valvola: ottone CW617N. Materiale guarnizioni: EPDM perossidico. IVAR PICC 01: 8 range di portata selezionabili; inserto in ottone e POM; diaframma in HNBR/EPDM perossidico; guarnizioni in EPDM perossidico. IVAR PICC 02: 41 range di portata selezionabili anche ad impianto funzionante; inserto in ottone e PSU; diaframma in HNBR/EPDM perossidico; guarnizioni in EPDM perossidico. IVAR PICC 03: 41 range di portata selezionabili anche ad impianto funzionante; da combinare ad attuatore termoelettrico IVAR TE 3003 (M30x1.5; regolazione ON/OFF 230 V AC o ON/OFF 24 V AC o proporzionale 0-10 V 24 V AC) o a servomotore assiale IVAR RV 03 (M30x1.5; regolazione 2 punti/3 punti 230 V AC o 2 punti/3 punti 24 V AC o proporzionale 0-10 V 24 V AC); pressione in chiusura max 6 bar; inserto in ottone e PSU/POM/PPS rinforzato con fibre di vetro; componenti metallici interni in acciaio inox; cono in PPS/EPDM perossidico; diaframma in HNBR/EPDM perossidico; guarnizioni in EPDM perossidico.

Conforme a EMCS

.RFA

Valvola per riscaldamento e raffreddamento

IVAR

Scarica
IVAR PICV 200-205-210 With PICC 22

PICV 200-205-210 With PICC 22

Valvola che mantiene costante la portata entro un certo range di pressione differenziale grazie ad un dispositivo a membrana con molla di contrasto. Fornita con due sedi G 1/4"F per prese piezometriche (IVAR AVB 10) e con tappi per sedi prese piezometriche e cartuccia. Connessioni PICV 200 (femmina): G 1"1/2F, G 2"F conformi ISO 228/1. Connessioni PICV 205 (maschio tenuta piana): G 2"M, G 2"1/2M conformi ISO 228/1. Connessioni PICV 210 (con bocchettoni): G 1"1/2M, G 2"M conformi ISO 228/1 ed EN 10226-1. Da combinare a cartuccia PICC 22. Connessione per PICC: W81x16. Compatibile con acqua o soluzioni glicolate max 30%. Temperatura operativa min: -20 °C. Temperatura operativa max: 120 °C. Pressione operativa max: 25 bar. Materiale valvola: ottone CW617N. Materiale guarnizioni: EPDM perossidico. IVAR PICC 22: 41 range di portata selezionabili anche ad impianto funzionante; inserto in ottone e PSU; diaframma in HNBR/EPDM perossidico; guarnizioni in EPDM perossidico.

IVAR

PICV 200-205-210 With PICC 22

Valvola che mantiene costante la portata entro un certo range di pressione differenziale grazie ad un dispositivo a membrana con molla di contrasto. Fornita con due sedi G 1/4"F per prese piezometriche (IVAR AVB 10) e con tappi per sedi prese piezometriche e cartuccia. Connessioni PICV 200 (femmina): G 1"1/2F, G 2"F conformi ISO 228/1. Connessioni PICV 205 (maschio tenuta piana): G 2"M, G 2"1/2M conformi ISO 228/1. Connessioni PICV 210 (con bocchettoni): G 1"1/2M, G 2"M conformi ISO 228/1 ed EN 10226-1. Da combinare a cartuccia PICC 22. Connessione per PICC: W81x16. Compatibile con acqua o soluzioni glicolate max 30%. Temperatura operativa min: -20 °C. Temperatura operativa max: 120 °C. Pressione operativa max: 25 bar. Materiale valvola: ottone CW617N. Materiale guarnizioni: EPDM perossidico. IVAR PICC 22: 41 range di portata selezionabili anche ad impianto funzionante; inserto in ottone e PSU; diaframma in HNBR/EPDM perossidico; guarnizioni in EPDM perossidico.

Conforme a EMCS

.RFA

Valvola per riscaldamento e raffreddamento

IVAR

Scarica
IVAR PICV 100-105-110 With PICC 11-12-13

PICV 100-105-110 With PICC 11-12-13

Valvola che mantiene costante la portata entro un certo range di pressione differenziale grazie ad un dispositivo a membrana con molla di contrasto. Fornita con due sedi G 1/4"F per prese piezometriche (IVAR AVB 10) e con tappi per sedi prese piezometriche e cartuccia. Connessioni PICV 100 (femmina): G 1"F, G 1"1/4F conformi ISO 228/1. Connessioni PICV 105 (maschio tenuta piana): G 1"M, G 1"1/4M, G 1"1/2M conformi ISO 228/1. Connessioni PICV 110 (con bocchettoni): G 3/4"M, G 1"M, G 1"1/4M conformi ISO 228/1 ed EN 10226-1. Da combinare a cartucce: PICC 11, PICC 12, PICC 13. Connessione per PICC: M54x1.5. Compatibile con acqua o soluzioni glicolate max 30%. Temperatura operativa min: -20 °C.Temperatura operativa max: 120 °C. Pressione operativa max: 25 bar. Pressione di chiusura max con PICC 13: 4 bar. Materiale valvola: ottone CW617N. Materiale guarnizioni: EPDM perossidico. IVAR PICC 11: 8 range di portata selezionabili; inserto in ottone e POM; diaframma in HNBR/EPDM perossidico; guarnizioni in EPDM perossidico. IVAR PICC 12: 41 range di portata selezionabili anche ad impianto funzionante; inserto in ottone e PSU; diaframma in HNBR/EPDM perossidico; guarnizioni in EPDM perossidico. IVAR PICC 13: 41 range di portata selezionabili anche ad impianto funzionante; da combinare a servomotore assiale IVAR RV 03 (M30x1.5; regolazione 2 punti/3 punti 230 V AC o 2 punti/3 punti 24 V AC o proporzionale 0-10 V 24 V AC); pressione in chiusura max 4 bar; inserto in ottone e PSU/POM/PPS rinforzato con fibre di vetro; componenti metallici interni in acciaio inox; cono in PPS/EPDM perossidico; diaframma in HNBR/EPDM perossidico; guarnizioni in EPDM perossidico.

IVAR

PICV 100-105-110 With PICC 11-12-13

Valvola che mantiene costante la portata entro un certo range di pressione differenziale grazie ad un dispositivo a membrana con molla di contrasto. Fornita con due sedi G 1/4"F per prese piezometriche (IVAR AVB 10) e con tappi per sedi prese piezometriche e cartuccia. Connessioni PICV 100 (femmina): G 1"F, G 1"1/4F conformi ISO 228/1. Connessioni PICV 105 (maschio tenuta piana): G 1"M, G 1"1/4M, G 1"1/2M conformi ISO 228/1. Connessioni PICV 110 (con bocchettoni): G 3/4"M, G 1"M, G 1"1/4M conformi ISO 228/1 ed EN 10226-1. Da combinare a cartucce: PICC 11, PICC 12, PICC 13. Connessione per PICC: M54x1.5. Compatibile con acqua o soluzioni glicolate max 30%. Temperatura operativa min: -20 °C.Temperatura operativa max: 120 °C. Pressione operativa max: 25 bar. Pressione di chiusura max con PICC 13: 4 bar. Materiale valvola: ottone CW617N. Materiale guarnizioni: EPDM perossidico. IVAR PICC 11: 8 range di portata selezionabili; inserto in ottone e POM; diaframma in HNBR/EPDM perossidico; guarnizioni in EPDM perossidico. IVAR PICC 12: 41 range di portata selezionabili anche ad impianto funzionante; inserto in ottone e PSU; diaframma in HNBR/EPDM perossidico; guarnizioni in EPDM perossidico. IVAR PICC 13: 41 range di portata selezionabili anche ad impianto funzionante; da combinare a servomotore assiale IVAR RV 03 (M30x1.5; regolazione 2 punti/3 punti 230 V AC o 2 punti/3 punti 24 V AC o proporzionale 0-10 V 24 V AC); pressione in chiusura max 4 bar; inserto in ottone e PSU/POM/PPS rinforzato con fibre di vetro; componenti metallici interni in acciaio inox; cono in PPS/EPDM perossidico; diaframma in HNBR/EPDM perossidico; guarnizioni in EPDM perossidico.

Conforme a EMCS

.RFA

Valvola per riscaldamento e raffreddamento

IVAR

Scarica
Unspecified Non-Return Valve

Non-Return Valve

Unspecified Valve

Unspecified

Non-Return Valve

Unspecified Valve

Conforme a EMCS

.RFA

Valvola per uso meccanico

Unspecified

Scarica
Unspecified Inlet Combination

Inlet Combination

Inlet Combination

Unspecified

Inlet Combination

Inlet Combination

Conforme a EMCS

.RFA

Valvola per uso meccanico

Unspecified

Scarica
Victaulic Series 768

Series 768

Dry valve

Victaulic

Series 768

Dry valve

Conforme a EMCS

.DWG .RFA

Valvola per uso meccanico

Victaulic

Scarica
Victaulic 731-D Series

731-D Series

Suction diffuser series 731-D with PN10/PN16 flange

Victaulic

731-D Series

Suction diffuser series 731-D with PN10/PN16 flange

Conforme a EMCS

.DWG .RFA

Valvola per uso meccanico

Victaulic

Scarica
Victaulic 776 Series

776 Series

Low pressure actuator

Victaulic

776 Series

Low pressure actuator

Conforme a EMCS

.DWG .RFA

Valvola per uso meccanico

Victaulic

Scarica
Victaulic 767 Series

767 Series

Electric -pneumatic actuators

Victaulic

767 Series

Electric -pneumatic actuators

Conforme a EMCS

.DWG .RFA

Valvola per uso meccanico

Victaulic

Scarica
Victaulic European Trim

European Trim

Alarm Check Valve

Victaulic

European Trim

Alarm Check Valve

Conforme a EMCS

.DWG .RFA

Valvola per uso meccanico

Victaulic

Scarica
Victaulic 798 Series

798 Series

Double pneumatic actuators

Victaulic

798 Series

Double pneumatic actuators

Conforme a EMCS

.DWG .RFA

Valvola per uso meccanico

Victaulic

Scarica
Victaulic cULus-FM Version

cULus-FM Version

Firelock alarm check valve

Victaulic

cULus-FM Version

Firelock alarm check valve

Conforme a EMCS

.DWG .RFA

Valvola per uso meccanico

Victaulic

Scarica
IVAR VCR 2132 NH HARMONIA Thermostatic valve

VCR 2132 NH HARMONIA Thermostatic valve

Valvola termostatizzabile a squadra con preregolazione della portata e bilanciamento dinamico della pressione, serie HARMONIA, con attacco maschio. Connessione tubo ferro x Connessione radiatore: EUROK x 1/2"M con o senza O-Ring. Ghiera con astina di comando sostituibile e ispezionabile ad impianto funzionante. Fluido: acqua, miscele acqua-glicole (30% glicole max). Temperatura max del fluido: 120° C. Pressione max di esercizio: 10 bar. Range pressione differenziale: 0.1÷0.6 bar. Materiale del corpo: ottone CW617N nichelato. Materiale guarnizioni e O-Ring: EPDM perossidico. Materiale molla, rondella e astina: acciaio inox. Materiale cappuccio di protezione: ABS arancione.

IVAR

VCR 2132 NH HARMONIA Thermostatic valve

Valvola termostatizzabile a squadra con preregolazione della portata e bilanciamento dinamico della pressione, serie HARMONIA, con attacco maschio. Connessione tubo ferro x Connessione radiatore: EUROK x 1/2"M con o senza O-Ring. Ghiera con astina di comando sostituibile e ispezionabile ad impianto funzionante. Fluido: acqua, miscele acqua-glicole (30% glicole max). Temperatura max del fluido: 120° C. Pressione max di esercizio: 10 bar. Range pressione differenziale: 0.1÷0.6 bar. Materiale del corpo: ottone CW617N nichelato. Materiale guarnizioni e O-Ring: EPDM perossidico. Materiale molla, rondella e astina: acciaio inox. Materiale cappuccio di protezione: ABS arancione.

Conforme a EMCS

.RFA

Valvola per riscaldamento e raffreddamento

IVAR

Scarica
IVAR VS 2102 NH HARMONIA Thermostatic valve

VS 2102 NH HARMONIA Thermostatic valve

Valvola termostatizzabile a corpo reverso con preregolazione della portata e bilanciamento dinamico della pressione, serie HARMONIA, con attacco maschio. Connessione tubo ferro x Connessione radiatore: EUROK x 1/2"M con o senza O-Ring. Ghiera con astina di comando sostituibile e ispezionabile ad impianto funzionante. Fluido: acqua, miscele acqua-glicole (30% glicole max). Temperatura max del fluido: 120° C. Pressione max di esercizio: 10 bar. Range pressione differenziale: 0.1÷0.6 bar. Materiale del corpo: ottone CW617N nichelato. Materiale guarnizioni e O-Ring: EPDM perossidico. Materiale molla, rondella e astina: acciaio inox. Materiale cappuccio di protezione: ABS arancione.

IVAR

VS 2102 NH HARMONIA Thermostatic valve

Valvola termostatizzabile a corpo reverso con preregolazione della portata e bilanciamento dinamico della pressione, serie HARMONIA, con attacco maschio. Connessione tubo ferro x Connessione radiatore: EUROK x 1/2"M con o senza O-Ring. Ghiera con astina di comando sostituibile e ispezionabile ad impianto funzionante. Fluido: acqua, miscele acqua-glicole (30% glicole max). Temperatura max del fluido: 120° C. Pressione max di esercizio: 10 bar. Range pressione differenziale: 0.1÷0.6 bar. Materiale del corpo: ottone CW617N nichelato. Materiale guarnizioni e O-Ring: EPDM perossidico. Materiale molla, rondella e astina: acciaio inox. Materiale cappuccio di protezione: ABS arancione.

Conforme a EMCS

.RFA

Valvola per riscaldamento e raffreddamento

IVAR

Scarica
IVAR VD 2105 NH HARMONIA Thermostatic valve

VD 2105 NH HARMONIA Thermostatic valve

Valvola termostatizzabile coassiale sinistra/destra con preregolazione della portata e bilanciamento dinamico della pressione, serie HARMONIA, con attacco femmina. Connessione tubo ferro x Connessione radiatore: 3/8"F x 3/8"M con o senza O-Ring, 1/2"F x 1/2"M con o senza O-Ring. Ghiera con astina di comando sostituibile e ispezionabile ad impianto funzionante. Fluido: acqua, miscele acqua-glicole (30% glicole max). Temperatura max del fluido: 120° C. Pressione max di esercizio: 10 bar. Range pressione differenziale: 0.1÷0.6 bar. Materiale del corpo: ottone CW617N nichelato. Materiale guarnizioni e O-Ring: EPDM perossidico. Materiale molla, rondella e astina: acciaio inox. Materiale cappuccio di protezione: ABS arancione.

IVAR

VD 2105 NH HARMONIA Thermostatic valve

Valvola termostatizzabile coassiale sinistra/destra con preregolazione della portata e bilanciamento dinamico della pressione, serie HARMONIA, con attacco femmina. Connessione tubo ferro x Connessione radiatore: 3/8"F x 3/8"M con o senza O-Ring, 1/2"F x 1/2"M con o senza O-Ring. Ghiera con astina di comando sostituibile e ispezionabile ad impianto funzionante. Fluido: acqua, miscele acqua-glicole (30% glicole max). Temperatura max del fluido: 120° C. Pressione max di esercizio: 10 bar. Range pressione differenziale: 0.1÷0.6 bar. Materiale del corpo: ottone CW617N nichelato. Materiale guarnizioni e O-Ring: EPDM perossidico. Materiale molla, rondella e astina: acciaio inox. Materiale cappuccio di protezione: ABS arancione.

Conforme a EMCS

.RFA

Valvola per riscaldamento e raffreddamento

IVAR

Scarica
IVAR VCR 2136 NH HARMONIA Thermostatic valve

VCR 2136 NH HARMONIA Thermostatic valve

Valvola termostatizzabile a squadra con preregolazione della portata e bilanciamento dinamico della pressione, serie HARMONIA, con attacco femmina. Connessione tubo ferro x Connessione radiatore: 3/8"F x 3/8"M con o senza O-Ring, 1/2"F x 1/2"M con o senza O-Ring. Ghiera con astina di comando sostituibile e ispezionabile ad impianto funzionante. Fluido: acqua, miscele acqua-glicole (30% glicole max). Temperatura max del fluido: 120° C. Pressione max di esercizio: 10 bar. Range pressione differenziale: 0.1÷0.6 bar. Materiale del corpo: ottone CW617N nichelato. Materiale guarnizioni e O-Ring: EPDM perossidico. Materiale molla, rondella e astina: acciaio inox. Materiale cappuccio di protezione: ABS arancione.

IVAR

VCR 2136 NH HARMONIA Thermostatic valve

Valvola termostatizzabile a squadra con preregolazione della portata e bilanciamento dinamico della pressione, serie HARMONIA, con attacco femmina. Connessione tubo ferro x Connessione radiatore: 3/8"F x 3/8"M con o senza O-Ring, 1/2"F x 1/2"M con o senza O-Ring. Ghiera con astina di comando sostituibile e ispezionabile ad impianto funzionante. Fluido: acqua, miscele acqua-glicole (30% glicole max). Temperatura max del fluido: 120° C. Pressione max di esercizio: 10 bar. Range pressione differenziale: 0.1÷0.6 bar. Materiale del corpo: ottone CW617N nichelato. Materiale guarnizioni e O-Ring: EPDM perossidico. Materiale molla, rondella e astina: acciaio inox. Materiale cappuccio di protezione: ABS arancione.

Conforme a EMCS

.RFA

Valvola per riscaldamento e raffreddamento

IVAR

Scarica
IVAR VD 2101 NH HARMONIA Thermostatic valve

VD 2101 NH HARMONIA Thermostatic valve

Valvola termostatizzabile coassiale sinistra/destra con preregolazione della portata e bilanciamento dinamico della pressione, serie HARMONIA, con attacco maschio. Connessione tubo ferro x Connessione radiatore: EUROK x 1/2"M con o senza O-Ring. Ghiera con astina di comando sostituibile e ispezionabile ad impianto funzionante. Fluido: acqua, miscele acqua-glicole (30% glicole max). Temperatura max del fluido: 120° C. Pressione max di esercizio: 10 bar. Range pressione differenziale: 0.1÷0.6 bar. Materiale del corpo: ottone CW617N nichelato. Materiale guarnizioni e O-Ring: EPDM perossidico. Materiale molla, rondella e astina: acciaio inox. Materiale cappuccio di protezione: ABS arancione.

IVAR

VD 2101 NH HARMONIA Thermostatic valve

Valvola termostatizzabile coassiale sinistra/destra con preregolazione della portata e bilanciamento dinamico della pressione, serie HARMONIA, con attacco maschio. Connessione tubo ferro x Connessione radiatore: EUROK x 1/2"M con o senza O-Ring. Ghiera con astina di comando sostituibile e ispezionabile ad impianto funzionante. Fluido: acqua, miscele acqua-glicole (30% glicole max). Temperatura max del fluido: 120° C. Pressione max di esercizio: 10 bar. Range pressione differenziale: 0.1÷0.6 bar. Materiale del corpo: ottone CW617N nichelato. Materiale guarnizioni e O-Ring: EPDM perossidico. Materiale molla, rondella e astina: acciaio inox. Materiale cappuccio di protezione: ABS arancione.

Conforme a EMCS

.RFA

Valvola per riscaldamento e raffreddamento

IVAR

Scarica
IVAR VCS 2162 NH SX – VCD 2162 NH DX HARMONIA Thermostatic valve

VCS 2162 NH SX – VCD 2162 NH DX HARMONIA Thermostatic valve

Valvola termostatizzabile diritta con preregolazione della portata e bilanciamento dinamico della pressione, serie HARMONIA, con attacco maschio. Connessione tubo ferro x Connessione radiatore: EUROK x 1/2"M con o senza O-Ring. Ghiera con astina di comando sostituibile e ispezionabile ad impianto funzionante. Fluido: acqua, miscele acqua-glicole (30% glicole max). Temperatura max del fluido: 120° C. Pressione max di esercizio: 10 bar. Range pressione differenziale: 0.1÷0.6 bar. Materiale del corpo: ottone CW617N nichelato. Materiale guarnizioni e O-Ring: EPDM perossidico. Materiale molla, rondella e astina: acciaio inox. Materiale cappuccio di protezione: ABS arancione.

IVAR

VCS 2162 NH SX – VCD 2162 NH DX HARMONIA Thermostatic valve

Valvola termostatizzabile diritta con preregolazione della portata e bilanciamento dinamico della pressione, serie HARMONIA, con attacco maschio. Connessione tubo ferro x Connessione radiatore: EUROK x 1/2"M con o senza O-Ring. Ghiera con astina di comando sostituibile e ispezionabile ad impianto funzionante. Fluido: acqua, miscele acqua-glicole (30% glicole max). Temperatura max del fluido: 120° C. Pressione max di esercizio: 10 bar. Range pressione differenziale: 0.1÷0.6 bar. Materiale del corpo: ottone CW617N nichelato. Materiale guarnizioni e O-Ring: EPDM perossidico. Materiale molla, rondella e astina: acciaio inox. Materiale cappuccio di protezione: ABS arancione.

Conforme a EMCS

.RFA

Valvola per riscaldamento e raffreddamento

IVAR

Scarica
IVAR VCS 2166 NH SX – VCD 2166 NH DX HARMONIA Thermostatic valve

VCS 2166 NH SX – VCD 2166 NH DX HARMONIA Thermostatic valve

Valvola termostatizzabile diritta con preregolazione della portata e bilanciamento dinamico della pressione, serie HARMONIA, con attacco femmina. Connessione tubo ferro x Connessione radiatore: 3/8"F x 3/8"M con o senza O-Ring, 1/2"F x 1/2"M con o senza O-Ring. Ghiera con astina di comando sostituibile e ispezionabile ad impianto funzionante. Fluido: acqua, miscele acqua-glicole (30% glicole max). Temperatura max del fluido: 120° C. Pressione max di esercizio: 10 bar. Range pressione differenziale: 0.1÷0.6 bar. Materiale del corpo: ottone CW617N nichelato. Materiale guarnizioni e O-Ring: EPDM perossidico. Materiale molla, rondella e astina: acciaio inox. Materiale cappuccio di protezione: ABS arancione.

IVAR

VCS 2166 NH SX – VCD 2166 NH DX HARMONIA Thermostatic valve

Valvola termostatizzabile diritta con preregolazione della portata e bilanciamento dinamico della pressione, serie HARMONIA, con attacco femmina. Connessione tubo ferro x Connessione radiatore: 3/8"F x 3/8"M con o senza O-Ring, 1/2"F x 1/2"M con o senza O-Ring. Ghiera con astina di comando sostituibile e ispezionabile ad impianto funzionante. Fluido: acqua, miscele acqua-glicole (30% glicole max). Temperatura max del fluido: 120° C. Pressione max di esercizio: 10 bar. Range pressione differenziale: 0.1÷0.6 bar. Materiale del corpo: ottone CW617N nichelato. Materiale guarnizioni e O-Ring: EPDM perossidico. Materiale molla, rondella e astina: acciaio inox. Materiale cappuccio di protezione: ABS arancione.

Conforme a EMCS

.RFA

Valvola per riscaldamento e raffreddamento

IVAR

Scarica
IVAR VS 2106 NH HARMONIA Thermostatic valve

VS 2106 NH HARMONIA Thermostatic valve

Valvola termostatizzabile a corpo reverso con preregolazione della portata e bilanciamento dinamico della pressione, serie HARMONIA, con attacco femmina. Connessione tubo ferro x Connessione radiatore: G 3/8"F x G 3/8"M con o senza O-Ring, G 1/2"F x G 1/2"M con o senza O-Ring. Ghiera con astina di comando sostituibile e ispezionabile ad impianto funzionante. Fluido: acqua, miscele acqua-glicole (30% glicole max). Temperatura max del fluido: 120° C. Pressione max di esercizio: 10 bar. Range pressione differenziale: 0.1÷0.6 bar. Materiale del corpo: ottone CW617N nichelato. Materiale guarnizioni e O-Ring: EPDM perossidico. Materiale molla, rondella e astina: acciaio inox. Materiale cappuccio di protezione: ABS arancione.

IVAR

VS 2106 NH HARMONIA Thermostatic valve

Valvola termostatizzabile a corpo reverso con preregolazione della portata e bilanciamento dinamico della pressione, serie HARMONIA, con attacco femmina. Connessione tubo ferro x Connessione radiatore: G 3/8"F x G 3/8"M con o senza O-Ring, G 1/2"F x G 1/2"M con o senza O-Ring. Ghiera con astina di comando sostituibile e ispezionabile ad impianto funzionante. Fluido: acqua, miscele acqua-glicole (30% glicole max). Temperatura max del fluido: 120° C. Pressione max di esercizio: 10 bar. Range pressione differenziale: 0.1÷0.6 bar. Materiale del corpo: ottone CW617N nichelato. Materiale guarnizioni e O-Ring: EPDM perossidico. Materiale molla, rondella e astina: acciaio inox. Materiale cappuccio di protezione: ABS arancione.

Conforme a EMCS

.RFA

Valvola per riscaldamento e raffreddamento

IVAR

Scarica
Belimo Electrical accessories

Electrical accessories

Electrical accessories

Belimo

Electrical accessories

Electrical accessories

Conforme a EMCS

.RFA

Valvola per uso meccanico

Belimo

Scarica
Belimo VAV-controlers and actuators

VAV-controlers and actuators

VAV-controlers and actuators

Belimo

VAV-controlers and actuators

VAV-controlers and actuators

Conforme a EMCS

.RFA

Valvola per uso meccanico

Belimo

Scarica
Kemper Figure 122 01 PN10

Figure 122 01 PN10

Butterfly Valve Wheel

Kemper

Figure 122 01 PN10

Butterfly Valve Wheel

Conforme a EMCS

.RFA

Valvola per uso meccanico

Kemper

Scarica
Kemper Figure 385 00

Figure 385 00

Globe Valve

Kemper

Figure 385 00

Globe Valve

Conforme a EMCS

.RFA

Valvola per uso meccanico

Kemper

Scarica
Kemper Figure 170 2G

Figure 170 2G

Globe Valve Skew

Kemper

Figure 170 2G

Globe Valve Skew

Conforme a EMCS

.RFA

Valvola per uso meccanico

Kemper

Scarica