16 BIM collections found from 5 manufacturer(s) in United States Of America
Mitsubishi Electric x-MEXT-i-G02 DW FC Coil Over R410A

x-MEXT-i-G02 DW FC Coil Over R410A

Direct expansion air conditioners for IT Cooling application with inverter, direct expansion with FC coil and water cooled, with over air supply for Cooling capacity between 029-108 kW

Mitsubishi Electric

x-MEXT-i-G02 DW FC Coil Over R410A

Direct expansion air conditioners for IT Cooling application with inverter, direct expansion with FC coil and water cooled, with over air supply for Cooling capacity between 029-108 kW

EMCS compliant

.DWG .RFA .IFC

Air Conditioner

Mitsubishi Electric

Download
Mitsubishi Electric x-MEXT-f-G02 DW FC Coil Under R410A

x-MEXT-f-G02 DW FC Coil Under R410A

Direct expansion air conditioners for IT Cooling application with fixed speed, direct expansion with FC coil and water cooled, with under air supply for Cooling capacity between 035-098 kW

Mitsubishi Electric

x-MEXT-f-G02 DW FC Coil Under R410A

Direct expansion air conditioners for IT Cooling application with fixed speed, direct expansion with FC coil and water cooled, with under air supply for Cooling capacity between 035-098 kW

EMCS compliant

.DWG .RFA .IFC

Air Conditioner

Mitsubishi Electric

Download
Mitsubishi Electric x-MEXT-i-G02 DW FC Coil Under R410A

x-MEXT-i-G02 DW FC Coil Under R410A

Direct expansion air conditioners for IT Cooling application with inverter, direct expansion with FC coil and water cooled, with under air supply for Cooling capacity between 029-108 kW

Mitsubishi Electric

x-MEXT-i-G02 DW FC Coil Under R410A

Direct expansion air conditioners for IT Cooling application with inverter, direct expansion with FC coil and water cooled, with under air supply for Cooling capacity between 029-108 kW

EMCS compliant

.DWG .RFA .IFC

Air Conditioner

Mitsubishi Electric

Download
Mitsubishi Electric x-MEXT-f-G02 DW FC Coil Over R410A

x-MEXT-f-G02 DW FC Coil Over R410A

Direct expansion air conditioners for IT Cooling application with fixed speed, direct expansion with FC coil and water cooled, with over air supply for Cooling capacity between 035-098 kW

Mitsubishi Electric

x-MEXT-f-G02 DW FC Coil Over R410A

Direct expansion air conditioners for IT Cooling application with fixed speed, direct expansion with FC coil and water cooled, with over air supply for Cooling capacity between 035-098 kW

EMCS compliant

.DWG .RFA .IFC

Air Conditioner

Mitsubishi Electric

Download
Climaveneta NX2-FC(NR2-FC)-G02(G06)(-Y)(-Z) 0384 - 0926

NX2-FC(NR2-FC)-G02(G06)(-Y)(-Z) 0384 - 0926

Air cooled chiller with free-cooling for high water temperature with refrigerant type R410A / R454B

Climaveneta

NX2-FC(NR2-FC)-G02(G06)(-Y)(-Z) 0384 - 0926

Air cooled chiller with free-cooling for high water temperature with refrigerant type R410A / R454B

EMCS compliant

.DWG .RFA .IFC

Chiller

Climaveneta

Download
Barcol-Air FCKC

FCKC

Fan coil unit, 4 circular outlets, 2-pipe

Barcol-Air

FCKC

Fan coil unit, 4 circular outlets, 2-pipe

EMCS compliant

.RFA

Fan Coil Unit

Barcol-Air

Download
Barcol-Air FCKF

FCKF

Fan coil unit with sound attenuator, 6 circular outlets, 4-pipe

Barcol-Air

FCKF

Fan coil unit with sound attenuator, 6 circular outlets, 4-pipe

EMCS compliant

.RFA

Fan Coil Unit

Barcol-Air

Download
Barcol-Air FCKA

FCKA

Fan coil unit, rectangular outlet, 2-pipe

Barcol-Air

FCKA

Fan coil unit, rectangular outlet, 2-pipe

EMCS compliant

.RFA

Fan Coil Unit

Barcol-Air

Download
Barcol-Air FCKY

FCKY

Fan coil unit with sound attenuator and fresh air connection, rectangular outlet, 2-pipe

Barcol-Air

FCKY

Fan coil unit with sound attenuator and fresh air connection, rectangular outlet, 2-pipe

EMCS compliant

.RFA

Fan Coil Unit

Barcol-Air

Download
Barcol-Air FCKZ

FCKZ

Fan coil unit with fresh air connection, 4 circular outlets, 2-pipe

Barcol-Air

FCKZ

Fan coil unit with fresh air connection, 4 circular outlets, 2-pipe

EMCS compliant

.RFA

Fan Coil Unit

Barcol-Air

Download
Barcol-Air FCKW

FCKW

Fan coil unit with fresh air connection, 4 circular outlets, 2-pipe

Barcol-Air

FCKW

Fan coil unit with fresh air connection, 4 circular outlets, 2-pipe

EMCS compliant

.RFA

Fan Coil Unit

Barcol-Air

Download
Barcol-Air FCKV

FCKV

Fan coil unit with fresh air connection, rectangular outlet, 2-pipe

Barcol-Air

FCKV

Fan coil unit with fresh air connection, rectangular outlet, 2-pipe

EMCS compliant

.RFA

Fan Coil Unit

Barcol-Air

Download
Barcol-Air FCKD

FCKD

Fan coil unit with sound attenuator, rectangular outlet, 2-pipe

Barcol-Air

FCKD

Fan coil unit with sound attenuator, rectangular outlet, 2-pipe

EMCS compliant

.RFA

Fan Coil Unit

Barcol-Air

Download
Signify Netherlands B.V. Lighting fixture FCC110

Lighting fixture FCC110

Orientation lighting fixture

Signify Netherlands B.V.

Lighting fixture FCC110

Orientation lighting fixture

EMCS compliant

.DWG .RFA

Lighting Fixture

Signify Netherlands B.V.

Download
IVAR CUBODOMO®

CUBODOMO®

Smart system for managing the heating system remotely via app. It allows remote control of all the zones in the house through time slots. Compatible with autonomous or centralized heating systems, at high or low temperature (e.g. radiators, radiant floor or ceiling, fan-coil). It can be used in public or private environment thanks to tamper controls. Installation of temperature sensors with no electrical connection. Temperature sensor with relay replaces the main chronothermostat and manages the switching on/off of the boiler (or zone valve with appropriate wiring). Operating system compatible with MyCubodomo App: Android 5.0 and iOS 8.0 onwards. Operating temperature range: -5 – 45 °C. Transmission frequency: 868,3 MHz. Signal range: 30 meters. Cube: power supply 5 V/1 A micro USB, Wi-Fi Standard FCC/CE/TELEC/KCC/SRRC/IC/NCC, protocollo Wi-Fi 802.11 b/g/n, frequency 2.4 GHz ~ 2.5 GHz (2400M ~ 2483.5M), dimensions (W x H x D) 100 x 100 x 100 mm. Temperature sensor (with or without relay): power supply 2 alkaline batteries AA (mod. LR6) 1.5 V, hysteresis on the set point temperature On-Off +/- 0,1°C, average battery life 3 years, dimensions (W x H x D) 87 x 87 x 28 mm. Actuator: power supply 3 alkaline batteries AA (mod. LR6) 1.5 V, connection M30x1.5, maximum closing distance 12 mm, insulation CLASS III, average battery life 3 years. Dimensions (W x H x D) 92 x 48 x 66 mm. Wiring Center: control unit equipped with radio module, power supply 230V 50/60 Hz, fuses F3 15A/250V, output switching relay max 2A/230V AC - 2A/30V DC, dimensions (W x H x D) 180 x 130 x 65 mm.

IVAR

CUBODOMO®

Smart system for managing the heating system remotely via app. It allows remote control of all the zones in the house through time slots. Compatible with autonomous or centralized heating systems, at high or low temperature (e.g. radiators, radiant floor or ceiling, fan-coil). It can be used in public or private environment thanks to tamper controls. Installation of temperature sensors with no electrical connection. Temperature sensor with relay replaces the main chronothermostat and manages the switching on/off of the boiler (or zone valve with appropriate wiring). Operating system compatible with MyCubodomo App: Android 5.0 and iOS 8.0 onwards. Operating temperature range: -5 – 45 °C. Transmission frequency: 868,3 MHz. Signal range: 30 meters. Cube: power supply 5 V/1 A micro USB, Wi-Fi Standard FCC/CE/TELEC/KCC/SRRC/IC/NCC, protocollo Wi-Fi 802.11 b/g/n, frequency 2.4 GHz ~ 2.5 GHz (2400M ~ 2483.5M), dimensions (W x H x D) 100 x 100 x 100 mm. Temperature sensor (with or without relay): power supply 2 alkaline batteries AA (mod. LR6) 1.5 V, hysteresis on the set point temperature On-Off +/- 0,1°C, average battery life 3 years, dimensions (W x H x D) 87 x 87 x 28 mm. Actuator: power supply 3 alkaline batteries AA (mod. LR6) 1.5 V, connection M30x1.5, maximum closing distance 12 mm, insulation CLASS III, average battery life 3 years. Dimensions (W x H x D) 92 x 48 x 66 mm. Wiring Center: control unit equipped with radio module, power supply 230V 50/60 Hz, fuses F3 15A/250V, output switching relay max 2A/230V AC - 2A/30V DC, dimensions (W x H x D) 180 x 130 x 65 mm.

EMCS compliant

.RFA

Motor Control

IVAR

Download
IVAR Fan-Coil Unit Kit

Fan-Coil Unit Kit

IVAR FCU-Kit: Pre-assembled brass multi-function bypass unit for fan-coil systems, chilled beams, heaters and other constant flow rate conditioning systems. Can be used for both heating and cooling. Consisting of: a pair of three-way valves for setting 5 different operating modes, a mesh filter, two loading/unloading taps, a Venturi orifice with a pair of piezometric sockets and a PICV flow regulator. Permissible differential pressure ranges and flow control range (for PICV): with PICC 03 cartridge (code 590123) 16- 200 kPa, 37-575 l/h; with PICC 03 cartridge (code 590124) 30-400 kPa, 64-1110 l/h. Mesh filter (500 μm) in stainless steel AISI 304. Connections to the primary circuit (with unions): 1/2 "F (DN 15) - 3/4 "F (DN 20). Connections to the secondary circuit: 1/2 "F (DN 15) - 3/4 "F (DN 20). Maximum operating pressure: 10 bar. Maximum operating temperature: 120 °C. Available with insulation shell in grey ARPRO 5135 FR with conductivity 0.037 W/mK, density 50 kg/m3, reaction to fire class HF-1 according to UL-94 standard.

IVAR

Fan-Coil Unit Kit

IVAR FCU-Kit: Pre-assembled brass multi-function bypass unit for fan-coil systems, chilled beams, heaters and other constant flow rate conditioning systems. Can be used for both heating and cooling. Consisting of: a pair of three-way valves for setting 5 different operating modes, a mesh filter, two loading/unloading taps, a Venturi orifice with a pair of piezometric sockets and a PICV flow regulator. Permissible differential pressure ranges and flow control range (for PICV): with PICC 03 cartridge (code 590123) 16- 200 kPa, 37-575 l/h; with PICC 03 cartridge (code 590124) 30-400 kPa, 64-1110 l/h. Mesh filter (500 μm) in stainless steel AISI 304. Connections to the primary circuit (with unions): 1/2 "F (DN 15) - 3/4 "F (DN 20). Connections to the secondary circuit: 1/2 "F (DN 15) - 3/4 "F (DN 20). Maximum operating pressure: 10 bar. Maximum operating temperature: 120 °C. Available with insulation shell in grey ARPRO 5135 FR with conductivity 0.037 W/mK, density 50 kg/m3, reaction to fire class HF-1 according to UL-94 standard.

EMCS compliant

.RVT .RFA

Fan Coil Unit

IVAR

Download