31 BIM collections found from 8 manufacturer(s) in Olanda
Vent-Axia B.V. Vent-Axia Uniflexplus+ 69 & 90

Vent-Axia Uniflexplus+ 69 & 90

Sistem flexibil de distribuție a aerului din plastic, diametru 69 și 90

Vent-Axia B.V.

Vent-Axia Uniflexplus+ 69 & 90

Sistem flexibil de distribuție a aerului din plastic, diametru 69 și 90

Conform cu EMCS

.RVT .DWG .RFA .PDF .IFC

Fitinguri - Ventilare

Vent-Axia B.V.

Descărcare
Vent-Axia B.V. Vent-Axia

Vent-Axia

Vent-Axia

Vent-Axia B.V.

Vent-Axia

Vent-Axia

PLS pentru Stabicad

Ventilare

Vent-Axia B.V.

Vizualizare
Vent-Axia B.V. Sentinel Kinetic F RH

Sentinel Kinetic F RH

Heat recovery unit

Vent-Axia B.V.

Sentinel Kinetic F RH

Heat recovery unit

Conform cu EMCS

.DWG .RFA

Schimbătoare de căldură - Ventilare

Vent-Axia B.V.

Descărcare
Vent-Axia B.V. Sentinel Kinetic F LH

Sentinel Kinetic F LH

Heat recovery unit

Vent-Axia B.V.

Sentinel Kinetic F LH

Heat recovery unit

Conform cu EMCS

.DWG .RFA

Schimbătoare de căldură - Ventilare

Vent-Axia B.V.

Descărcare
Vent-Axia B.V. Sentinel Kinetic B RH

Sentinel Kinetic B RH

Heat recovery unit

Vent-Axia B.V.

Sentinel Kinetic B RH

Heat recovery unit

Conform cu EMCS

.DWG .RFA

Schimbătoare de căldură - Ventilare

Vent-Axia B.V.

Descărcare
Vent-Axia B.V. Sentinel Kinetic Plus LH

Sentinel Kinetic Plus LH

Heat recovery unit

Vent-Axia B.V.

Sentinel Kinetic Plus LH

Heat recovery unit

Conform cu EMCS

.DWG .RFA

Schimbătoare de căldură - Ventilare

Vent-Axia B.V.

Descărcare
Vent-Axia B.V. Sentinel Kinetic B LH

Sentinel Kinetic B LH

Heat recovery unit

Vent-Axia B.V.

Sentinel Kinetic B LH

Heat recovery unit

Conform cu EMCS

.DWG .RFA

Schimbătoare de căldură - Ventilare

Vent-Axia B.V.

Descărcare
Vent-Axia B.V. Sentinel Kinetic Plus RH

Sentinel Kinetic Plus RH

Heat recovery unit

Vent-Axia B.V.

Sentinel Kinetic Plus RH

Heat recovery unit

Conform cu EMCS

.DWG .RFA

Schimbătoare de căldură - Ventilare

Vent-Axia B.V.

Descărcare
Standard Generic Wall Vent Cover

Generic Wall Vent Cover

Generic Wall Vent Cover

Standard

Generic Wall Vent Cover

Generic Wall Vent Cover

Conform cu EMCS

.RFA

Air terminal

Standard

Descărcare
Ubbink FloorVent New construction, FloorVent Renovation tube

FloorVent New construction, FloorVent Renovation tube

Rectangular floor vent without wall grille

Ubbink

FloorVent New construction, FloorVent Renovation tube

Rectangular floor vent without wall grille

Conform cu EMCS

.DWG .RFA .IFC

Floor Vent

Ubbink

Descărcare
Ubbink FloorVent New construction, FloorVent Renovation tube

FloorVent New construction, FloorVent Renovation tube

Floor vent with wall grille and Renovation Tube

Ubbink

FloorVent New construction, FloorVent Renovation tube

Floor vent with wall grille and Renovation Tube

Conform cu EMCS

.DWG .RFA .IFC

Fitinguri - Ventilare

Ubbink

Descărcare
Flamco Flexvent Top

Flexvent Top

Automatic Air Vent

Flamco

Flexvent Top

Automatic Air Vent

Conform cu EMCS

.RFA

Supapă de aerisire automată

Flamco

Descărcare
Flamco Flexvent Pro

Flexvent Pro

Flexvent Pro Automatic Air Vent

Flamco

Flexvent Pro

Flexvent Pro Automatic Air Vent

Conform cu EMCS

.RFA

Supapă de aerisire automată

Flamco

Descărcare
Ubbink Sewer Vent Ubiflex

Sewer Vent Ubiflex

Sewer ventilation Ubiflex universal 5-55 °

Ubbink

Sewer Vent Ubiflex

Sewer ventilation Ubiflex universal 5-55 °

Conform cu EMCS

.DWG .RFA .IFC

Piese de scurgere

Ubbink

Descărcare
Valsir  Ventilation Cowl

Ventilation Cowl

Grey PP Vent Cowl 50

Valsir

Ventilation Cowl

Grey PP Vent Cowl 50

Conform cu EMCS

.RFA

Piese finale de acoperiș - Sanitare și Canalizare

Valsir

Descărcare
Siegenia AEROPAC

AEROPAC

AEROPAC: active sound absorbing ventilator with filter technology

Siegenia

AEROPAC

AEROPAC: active sound absorbing ventilator with filter technology

Conform cu EMCS

.DWG .RFA .IFC

Ventilatoare

Siegenia

Descărcare
Siegenia AEROTUBE DD 110

AEROTUBE DD 110

AEROTUBE DD 110: Passive ventilator for air supply or extraction

Siegenia

AEROTUBE DD 110

AEROTUBE DD 110: Passive ventilator for air supply or extraction

Conform cu EMCS

.DWG .RFA .IFC

Valve de ventilare

Siegenia

Descărcare
Siegenia AEROTUBE AZ SMART

AEROTUBE AZ SMART

AEROTUBE AZ smart: Can be used as an air supply or air extraction unit

Siegenia

AEROTUBE AZ SMART

AEROTUBE AZ smart: Can be used as an air supply or air extraction unit

Conform cu EMCS

.DWG .RFA .IFC

Valve de ventilare

Siegenia

Descărcare
IVAR BRASS-ROD MANIFOLDS_KC01KC

BRASS-ROD MANIFOLDS_KC01KC

Kit made of flow manifold with double micrometric adjustment lockshields, return manifold with manually operated isolation valves, brackets, terminals, filling/drainage valves, air vent valves and EUROK connections. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished.  Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 120°C. Maximum operating pressure: 10 bar. Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 2 to 13 ways.

IVAR

BRASS-ROD MANIFOLDS_KC01KC

Kit made of flow manifold with double micrometric adjustment lockshields, return manifold with manually operated isolation valves, brackets, terminals, filling/drainage valves, air vent valves and EUROK connections. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished.  Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 120°C. Maximum operating pressure: 10 bar. Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 2 to 13 ways.

Conform cu EMCS

.RFA

Distribuitoare - Termice

IVAR

Descărcare
IVAR BRASS-ROD MANIFOLDS KC02KC

BRASS-ROD MANIFOLDS KC02KC

Kit made of flow manifold with flow meters/adjusters FLUXER (0-5 l/min), return manifold with manually operated isolation valves, brackets, terminals, filling/drainage valves, air vent valves and EUROK connections. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished.  Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 120°C. Maximum operating pressure: 10 bar.  Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 2 to 13 ways.

IVAR

BRASS-ROD MANIFOLDS KC02KC

Kit made of flow manifold with flow meters/adjusters FLUXER (0-5 l/min), return manifold with manually operated isolation valves, brackets, terminals, filling/drainage valves, air vent valves and EUROK connections. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished.  Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 120°C. Maximum operating pressure: 10 bar.  Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 2 to 13 ways.

Conform cu EMCS

.RFA

Distribuitoare - Termice

IVAR

Descărcare
IVAR AC659N - Orientable terminal for EASY LOCK modular manifolds

AC659N - Orientable terminal for EASY LOCK modular manifolds

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves). Orientable terminal for EASY LOCK modular manifolds complete with drainage valve and automatic air vent valve. Material: nichel plated brass. Size: M 1/2".

IVAR

AC659N - Orientable terminal for EASY LOCK modular manifolds

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves).

Orientable terminal for EASY LOCK modular manifolds complete with drainage valve and automatic air vent valve. Material: nichel plated brass. Size: M 1/2".

Conform cu EMCS

.RFA

Fitinguri - Sanitare și Canalizare

IVAR

Descărcare
IVAR TECHNOMIX

TECHNOMIX

IVAR TECHNO TNB cod. 508100: mixing and boosting unit for radiant installations complete with two-way mixing valve, balancing valve (on the cold way), fill/drain valve, manual air vent valve, two thermometers 0÷80 °C (on delivery of boiler circuit and mixed circuit), temperature sensor pocket (on delivery of mixed circuit), shut off valve (on return of boiler circuit), boiler circuit connections G 1”F (centre distance 200 mm) and mixed circuit connections G 1”M (centre distance 200 mm). Upper and lower parts made of nickel-plated CB753S brass; pipe made of nickel-plated half-hard copper; gaskets and O-rings made of peroxide-cured EPDM; other parts made of CW617N brass. Max operating temperature 100 °C. Max operating pressure 10 bar. Fixed point mixing 20÷60 °C by thermostatic control head with remote sensor T3011 included. Max differential pressure at mixing valve ends 250 mbar. Pump space 130 mm with G 1”1/2F flat seal connections.

IVAR

TECHNOMIX

IVAR TECHNO TNB cod. 508100: mixing and boosting unit for radiant installations complete with two-way mixing valve, balancing valve (on the cold way), fill/drain valve, manual air vent valve, two thermometers 0÷80 °C (on delivery of boiler circuit and mixed circuit), temperature sensor pocket (on delivery of mixed circuit), shut off valve (on return of boiler circuit), boiler circuit connections G 1”F (centre distance 200 mm) and mixed circuit connections G 1”M (centre distance 200 mm). Upper and lower parts made of nickel-plated CB753S brass; pipe made of nickel-plated half-hard copper; gaskets and O-rings made of peroxide-cured EPDM; other parts made of CW617N brass. Max operating temperature 100 °C. Max operating pressure 10 bar. Fixed point mixing 20÷60 °C by thermostatic control head with remote sensor T3011 included. Max differential pressure at mixing valve ends 250 mbar. Pump space 130 mm with G 1”1/2F flat seal connections.

Conform cu EMCS

.RVT .RFA

Distribuitoare - Termice

IVAR

Descărcare
IVAR Dirtstop® XL

Dirtstop® XL

IVAR Dirtstop® XL: triple effect magnetic dirt separator: cyclonic action guaranteed by a patented internal insert, developed to guide the fluid directed to the boiler in order to maximize the slowing down and decantation of the debris; subsequent removal of ferrous particles by means of a neodymium magnet, magnetic field 14000 G; mechanical filtration with an 800 μm mesh filter (pre- assembled 500 μm filter for the first cleaning of the system). Internal components completely inspectable, removable and washable by removing the upper plug, with the special lever provided. Manual air vent valve. Draining valve with opening lever and tap. Swivel fitting for mounting to the pipeline in different orientations, with the special lever provided. Allowed installation on horizontal, vertical or oblique lines. Buttonhole on magnetic insert, sealing band supplied. Materials: body, cyclonic insert and cap in PA66 + GF 30%; "T" joint and locking ring nut in PA66 + GF 30%; filters in stainless steel AISI 304; seals in peroxide EPDM. Compatible fluids: water; water + glycol max 50%. Maximum recommended flow rate: 2.13 m3/h. Maximum operating pressure: 3 bar. Operating temperature: 0-90 °C. Flow coefficient Kv: 6.7 m3 /h. Connections: Ø22 x Ø22 copper pipe (520124); 3/4" F x 3/4" F (520135); 1"F x 1" F (520136); 1"1/4 F x 1"1/4 F (520139).

IVAR

Dirtstop® XL

IVAR Dirtstop® XL: triple effect magnetic dirt separator: cyclonic action guaranteed by a patented internal insert, developed to guide the fluid directed to the boiler in order to maximize the slowing down and decantation of the debris; subsequent removal of ferrous particles by means of a neodymium magnet, magnetic field 14000 G; mechanical filtration with an 800 μm mesh filter (pre- assembled 500 μm filter for the first cleaning of the system). Internal components completely inspectable, removable and washable by removing the upper plug, with the special lever provided. Manual air vent valve. Draining valve with opening lever and tap. Swivel fitting for mounting to the pipeline in different orientations, with the special lever provided. Allowed installation on horizontal, vertical or oblique lines. Buttonhole on magnetic insert, sealing band supplied. Materials: body, cyclonic insert and cap in PA66 + GF 30%; "T" joint and locking ring nut in PA66 + GF 30%; filters in stainless steel AISI 304; seals in peroxide EPDM. Compatible fluids: water; water + glycol max 50%. Maximum recommended flow rate: 2.13 m3/h. Maximum operating pressure: 3 bar. Operating temperature: 0-90 °C. Flow coefficient Kv: 6.7 m3 /h. Connections: Ø22 x Ø22 copper pipe (520124); 3/4" F x 3/4" F (520135); 1"F x 1" F (520136); 1"1/4 F x 1"1/4 F (520139).

Conform cu EMCS

.RVT .RFA

Unități de control - Termice

IVAR

Descărcare
IVAR IVARSAT-H VNR

IVARSAT-H VNR

Satellite module that independently manages high-temperature heating (direct circuit) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; domestic water preheating device; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; summer/winter two-way valve; pocket for temperature immersion probe on delivery side of primary circuit; balancing lockshield of primary circuit with double micrometrical adjustment; balancing lockshield of heating/domestic water circuit; differential overpressure by-pass valve on primary circuit; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. Model “1” with high-temperature domestic water outlet. Model “R” with hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor. In compliance with Belgaqua.

IVAR

IVARSAT-H VNR

Satellite module that independently manages high-temperature heating (direct circuit) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; domestic water preheating device; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; summer/winter two-way valve; pocket for temperature immersion probe on delivery side of primary circuit; balancing lockshield of primary circuit with double micrometrical adjustment; balancing lockshield of heating/domestic water circuit; differential overpressure by-pass valve on primary circuit; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. Model “1” with high-temperature domestic water outlet. Model “R” with hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor. In compliance with Belgaqua.

Conform cu EMCS

.RFA

Distribuitoare - Termice

IVAR

Descărcare
IVAR IVARSAT-HL-HLE

IVARSAT-HL-HLE

Satellite module that independently manages high-temperature and low-temperature heating (direct and mixed circuits) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; mixing valve for fixed point mixing (with thermostatic control head and remote contact probe) or outside compensated temperature mixing (with axial servomotor and control unit); three-speed pump / model “E” with variable-speed pump EEI<20; summer/winter two-way valve on high-temperature and low-temperature circuits; pocket for temperature immersion probe on delivery side of primary circuit; balancing valve on primary circuit; balancing by-pass valve on mixed circuit; balancing lockshield of heating/domestic water circuit; hydraulic separator with built-in check valve; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. High-temperature domestic water outlet. Hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor.

IVAR

IVARSAT-HL-HLE

Satellite module that independently manages high-temperature and low-temperature heating (direct and mixed circuits) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; mixing valve for fixed point mixing (with thermostatic control head and remote contact probe) or outside compensated temperature mixing (with axial servomotor and control unit); three-speed pump / model “E” with variable-speed pump EEI<20; summer/winter two-way valve on high-temperature and low-temperature circuits; pocket for temperature immersion probe on delivery side of primary circuit; balancing valve on primary circuit; balancing by-pass valve on mixed circuit; balancing lockshield of heating/domestic water circuit; hydraulic separator with built-in check valve; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. High-temperature domestic water outlet. Hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor.

Conform cu EMCS

.RFA

Distribuitoare - Termice

IVAR

Descărcare
IVAR COMBIMIX

COMBIMIX

Mixing and boosting unit IVAR COMBIMIX for radiant installations complete with two-way mixing valve, balancing valve (on the cold way), two shut-off ball valves for the pump, two fill/drain valves, two automatic air vent valves, three thermometers 0÷80 °C (on delivery and return of boiler circuit and on delivery of mixed circuit), temperature sensor pocket (on delivery of mixed circuit), shut-off valve (on return of boiler circuit), boiler circuit connections G 1”F (centre distance 200 mm) and mixed circuit connections G 1”M with swivelling nipples (centre distance 200 mm). Upper and lower parts made of nickel-plated CB753S brass; pipe made of nickel-plated half-hard copper; gaskets and O-rings made of peroxide-cured EPDM; other parts made of CW617N brass. Max operating temperature 100 °C. Max operating pressure 10 bar. Fixed point mixing 20÷60 °C by thermostatic control head with remote sensor T5011 included (max differential pressure at mixing valve ends 250 mbar) or set up for outside compensated temperature mixing by integrating axial servomotor IVAR RV 01 or thermoelectric actuator IVAR TE 3061. Differential bypass valve (optional) 0.2÷0.6 bar with half-hard nickel-plated pipe. Pump space 130 mm or 180 mm, G 1”1/2F flat seal connections. Equipped with variable-speed electronic pump WILO4F or variable-speed electronic pump WILO4F-180 or without pump. Accessories: high-temperature kit with pair of manifolds 1” x EUROK with shut-off and lockshield valves CEP/02 I – CEP/03 I (2 ways) – (3 ways), high-temperature kit with pair of simple manifolds 1” x EUROK CEP/02 – CEP/03 (2 ways) – (3 ways), insulation shell ACM 01, threaded spacer for pumps AC 633.

IVAR

COMBIMIX

Mixing and boosting unit IVAR COMBIMIX for radiant installations complete with two-way mixing valve, balancing valve (on the cold way), two shut-off ball valves for the pump, two fill/drain valves, two automatic air vent valves, three thermometers 0÷80 °C (on delivery and return of boiler circuit and on delivery of mixed circuit), temperature sensor pocket (on delivery of mixed circuit), shut-off valve (on return of boiler circuit), boiler circuit connections G 1”F (centre distance 200 mm) and mixed circuit connections G 1”M with swivelling nipples (centre distance 200 mm). Upper and lower parts made of nickel-plated CB753S brass; pipe made of nickel-plated half-hard copper; gaskets and O-rings made of peroxide-cured EPDM; other parts made of CW617N brass. Max operating temperature 100 °C. Max operating pressure 10 bar. Fixed point mixing 20÷60 °C by thermostatic control head with remote sensor T5011 included (max differential pressure at mixing valve ends 250 mbar) or set up for outside compensated temperature mixing by integrating axial servomotor IVAR RV 01 or thermoelectric actuator IVAR TE 3061. Differential bypass valve (optional) 0.2÷0.6 bar with half-hard nickel-plated pipe. Pump space 130 mm or 180 mm, G 1”1/2F flat seal connections. Equipped with variable-speed electronic pump WILO4F or variable-speed electronic pump WILO4F-180 or without pump. Accessories: high-temperature kit with pair of manifolds 1” x EUROK with shut-off and lockshield valves CEP/02 I – CEP/03 I (2 ways) – (3 ways), high-temperature kit with pair of simple manifolds 1” x EUROK CEP/02 – CEP/03 (2 ways) – (3 ways), insulation shell ACM 01, threaded spacer for pumps AC 633.

Conform cu EMCS

.RVT .RFA

Distribuitoare - Termice

IVAR

Descărcare
IVAR IVARSAT-H

IVARSAT-H

Satellite module that independently manages high-temperature heating (direct circuit) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; domestic water preheating device; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; summer/winter two-way valve; pocket for temperature immersion probe on delivery side of primary circuit; balancing lockshield of primary circuit with double micrometrical adjustment; balancing lockshield of heating/domestic water circuit; differential overpressure by-pass valve on primary circuit; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. Model “1” with high-temperature domestic water outlet. Model “R” with hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor.

IVAR

IVARSAT-H

Satellite module that independently manages high-temperature heating (direct circuit) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; domestic water preheating device; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; summer/winter two-way valve; pocket for temperature immersion probe on delivery side of primary circuit; balancing lockshield of primary circuit with double micrometrical adjustment; balancing lockshield of heating/domestic water circuit; differential overpressure by-pass valve on primary circuit; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. Model “1” with high-temperature domestic water outlet. Model “R” with hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor.

Conform cu EMCS

.RFA

Distribuitoare - Termice

IVAR

Descărcare
IVAR IVARSAT-L-LE

IVARSAT-L-LE

Satellite module that independently manages low-temperature heating (mixed circuit) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; mixing valve for fixed point mixing (with thermostatic control head and remote contact probe) or outside compensated temperature mixing (with axial servomotor and control unit); three-speed pump / model “E” with variable-speed pump EEI<20; summer/winter two-way valve; pocket for temperature immersion probe on delivery side of primary circuit; balancing valve on primary circuit; balancing by-pass valve on mixed circuit; balancing lockshield of heating/domestic water circuit; hydraulic separator with built-in check valve; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. Model “1” with high-temperature domestic water outlet. Model “R” with hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor.

IVAR

IVARSAT-L-LE

Satellite module that independently manages low-temperature heating (mixed circuit) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; mixing valve for fixed point mixing (with thermostatic control head and remote contact probe) or outside compensated temperature mixing (with axial servomotor and control unit); three-speed pump / model “E” with variable-speed pump EEI<20; summer/winter two-way valve; pocket for temperature immersion probe on delivery side of primary circuit; balancing valve on primary circuit; balancing by-pass valve on mixed circuit; balancing lockshield of heating/domestic water circuit; hydraulic separator with built-in check valve; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. Model “1” with high-temperature domestic water outlet. Model “R” with hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor.

Conform cu EMCS

.RFA

Distribuitoare - Termice

IVAR

Descărcare
IVAR MULTIMIX

MULTIMIX

Distribution and mixing system IVAR MULTIMIX for thermal power stations, modular with: - Manifold made of CB753S brass from casting with adjustable and interceptable hydraulic separator integrated. Complete with union with swivel fittings G 1” for the connection to distribution kits, shut-off ball valves DN 25 at the inlets, thermomanometer 0-6 bar/0-120 ◦C and automatic air vent valve. 2-way or 3-way versions available. Possibility of connection to the primary circuit from above, below, right or left. Expandable by connecting to other manifolds with swivel nipples G 1”. Other components made of CW617N brass. Gaskets and o-rings made of Peroxide-cured EPDM. Connections to the primary circuit G 1”F, centre distance delivery/return 52 mm (inlet from the side), 197 mm (inlet from above or below, 2-way manifold), 170 mm (inlet from above or below, 3-way manifold); connections to the distribution circuits with swivel nut G 1”F, centre distance delivery/return 45 mm. Max operating temperature 120 ◦C. Max operating pressure 10 bar. Max primary circuit flow rate 3500 l/h. - High-temperature direct flow kit complete with telescopic system for pump connection, shut-off ball valves for pump connection, delivery and return thermometers 0÷80 ◦C; check valve. Primary circuit connections G 1” M, delivery/return centre distance 45 mm; distribution circuits connections G 3/4”F, delivery/return centre distance 90 mm. Parts from casting: CB753S brass. Other parts made of CW617N brass. Gaskets and o-rings: peroxide-cured EPDM. Max operating temperature (pump excluded) 120 ◦C. Max operating pressure 10 bar. - Low temperature mixing kit complete with 3-way mixing valve with headwork for thermostatic or motorisable control, secondary bypass with micrometric dually adjusted lockshields and position memory, telescopic system for pump connection, shut-off ball valves for pump connection, delivery and return thermometers 0÷80 ◦C, check valve, fixed setting safety thermostat 60◦C. Primary circuit connections (manifold-separator) G 1”M, centre distance delivery/return 45 mm; heating circuits connections G 3/4”F, centre distance delivery/return 90 mm. Parts from casting: CB753S brass. Other parts: CW617N brass. Gaskets and o-rings: peroxide-cured EPDM. Max operating temperature (pump excluded) 120 ◦C. Max operating pressure 10 bar. - Variable-speed electronic pump WILO4F centre distance 130 mm. - 3-speed standard pump WILO3F centre distance 130 mm. - Polypropylene insulation shell. - Wall fitted cabinet with variable height and depth. - T 5011 U: thermostatic head with incorporated control and immersion remote sensor. Connection: M30 x 1.5. Probe holder connection: 1/2". Range: 30-55 °C. Cable lenght: 2 m. - RV 01: axial motor. Connection: M30 x 1.5. 3-point adjustment 230 V AC or 24 V AC or proportional 0-10 V 24 V AC.

IVAR

MULTIMIX

Distribution and mixing system IVAR MULTIMIX for thermal power stations, modular with: - Manifold made of CB753S brass from casting with adjustable and interceptable hydraulic separator integrated. Complete with union with swivel fittings G 1” for the connection to distribution kits, shut-off ball valves DN 25 at the inlets, thermomanometer 0-6 bar/0-120 ◦C and automatic air vent valve. 2-way or 3-way versions available. Possibility of connection to the primary circuit from above, below, right or left. Expandable by connecting to other manifolds with swivel nipples G 1”. Other components made of CW617N brass. Gaskets and o-rings made of Peroxide-cured EPDM. Connections to the primary circuit G 1”F, centre distance delivery/return 52 mm (inlet from the side), 197 mm (inlet from above or below, 2-way manifold), 170 mm (inlet from above or below, 3-way manifold); connections to the distribution circuits with swivel nut G 1”F, centre distance delivery/return 45 mm. Max operating temperature 120 ◦C. Max operating pressure 10 bar. Max primary circuit flow rate 3500 l/h. - High-temperature direct flow kit complete with telescopic system for pump connection, shut-off ball valves for pump connection, delivery and return thermometers 0÷80 ◦C; check valve. Primary circuit connections G 1” M, delivery/return centre distance 45 mm; distribution circuits connections G 3/4”F, delivery/return centre distance 90 mm. Parts from casting: CB753S brass. Other parts made of CW617N brass. Gaskets and o-rings: peroxide-cured EPDM. Max operating temperature (pump excluded) 120 ◦C. Max operating pressure 10 bar. - Low temperature mixing kit complete with 3-way mixing valve with headwork for thermostatic or motorisable control, secondary bypass with micrometric dually adjusted lockshields and position memory, telescopic system for pump connection, shut-off ball valves for pump connection, delivery and return thermometers 0÷80 ◦C, check valve, fixed setting safety thermostat 60◦C. Primary circuit connections (manifold-separator) G 1”M, centre distance delivery/return 45 mm; heating circuits connections G 3/4”F, centre distance delivery/return 90 mm. Parts from casting: CB753S brass. Other parts: CW617N brass. Gaskets and o-rings: peroxide-cured EPDM. Max operating temperature (pump excluded) 120 ◦C. Max operating pressure 10 bar. - Variable-speed electronic pump WILO4F centre distance 130 mm. - 3-speed standard pump WILO3F centre distance 130 mm. - Polypropylene insulation shell. - Wall fitted cabinet with variable height and depth. - T 5011 U: thermostatic head with incorporated control and immersion remote sensor. Connection: M30 x 1.5. Probe holder connection: 1/2". Range: 30-55 °C. Cable lenght: 2 m. - RV 01: axial motor. Connection: M30 x 1.5. 3-point adjustment 230 V AC or 24 V AC or proportional 0-10 V 24 V AC.

Conform cu EMCS

.RVT .RFA

Distribuitoare - Termice

IVAR

Descărcare
IVAR UNIMIX / UNIMIX-C

UNIMIX / UNIMIX-C

Mixing and pump units for radiant systems UNIMIX/UNIMIC-C modular with: UM 01 – UM 01D/S: regulation unit UNIMIX with/without pump complete with 3-way mixing valve with headwork for thermostatic control, secondary by-pass with double micrometric adjustment and position memory, primary by-pass for recirculation, thermomanometer 0÷120 °C 0÷6 bar for mixed water, thermometers 0÷80 °C for delivery and return waters, probe pocket for mixed water, shut-off ball valves G 1” secondary side and automatic air vent valve. Available with or without straight or angled shut-off ball valves G 3/4”F on primary side. Available with or without 3-speed standard pump WILO3F centre distance 130 mm or variable-speed electronic pump WILO4F centre distance 130 mm. Body made of nickel-plated CB753S brass; gaskets and O-rings made of peroxide-cured EPDM; other parts made of CW617N brass. Max operating temperature 100 °C. Max operating pressure 10 bar. Max differential pressure at mixing valve ends 250 mbar. UMC 01 – UMC 01D/S: regulation unit UNIMIX-C with/without pump complete with 3-way mixing valve with headwork for thermostatic control, secondary by-pass with double micrometric adjustment and position memory, primary by-pass for recirculation, thermometer 0÷80 °C for mixed water and probe pocket for mixed water. Available with or without straight or angled shut-off ball valves G 3/4”F on primary side. Available with or without 3-speed standard pump WILO3F centre distance 130 mm or variable-speed electronic pump WILO4F centre distance 130 mm. Body made of nickel-plated CB753S brass; gaskets and O-rings made of peroxide-cured EPDM; other parts made of CW617N brass. Max operating temperature 100 °C. Max operating pressure 10 bar. Max differential pressure at mixing valve ends 250 mbar. AUM 03: expanded polypropylene insulating cover. T 5011 U: thermostatic head with incorporated control and immersion remote sensor. Range 30÷55 °C o 25÷50 °C. Cable lengh 2 m. RV 01: axial servomotor M30x1.5. 3-point adjustment 230 V AC or proportional 0-10 V 24 V AC with display. AUM 01 - AUM 11 D/S: high-temperature kit for UNIMIX/UNIMIX-C with primary side connections G 1” and plain manifolds with 3 outlets (EUROK outlets). Complete with fill/drain valve and differential pressure by-pass valve 0.2÷0.6 bar. Available with or without straight or angled shut-off ball valves G 1” primary side. AUM 02 - AUM 12 D/S: high-temperature kit for UNIMIX/UNIMIX-C with primary side connections G 1” and manifolds with 3 outlets (delivery: double micrometric adjustment lockshield; return: headwork for thermostatic control with protection cap; EUROK outlets). Complete with fill/drain valve and differential pressure by-pass valve 0.2÷0.6 bar. Available with or without straight or angled shut-off ball valves G 1”F on primary side. AC 613 FU: fixed setting 60 °C safety thermostat pre-wired.

IVAR

UNIMIX / UNIMIX-C

Mixing and pump units for radiant systems UNIMIX/UNIMIC-C modular with: UM 01 – UM 01D/S: regulation unit UNIMIX with/without pump complete with 3-way mixing valve with headwork for thermostatic control, secondary by-pass with double micrometric adjustment and position memory, primary by-pass for recirculation, thermomanometer 0÷120 °C 0÷6 bar for mixed water, thermometers 0÷80 °C for delivery and return waters, probe pocket for mixed water, shut-off ball valves G 1” secondary side and automatic air vent valve. Available with or without straight or angled shut-off ball valves G 3/4”F on primary side. Available with or without 3-speed standard pump WILO3F centre distance 130 mm or variable-speed electronic pump WILO4F centre distance 130 mm. Body made of nickel-plated CB753S brass; gaskets and O-rings made of peroxide-cured EPDM; other parts made of CW617N brass. Max operating temperature 100 °C. Max operating pressure 10 bar. Max differential pressure at mixing valve ends 250 mbar. UMC 01 – UMC 01D/S: regulation unit UNIMIX-C with/without pump complete with 3-way mixing valve with headwork for thermostatic control, secondary by-pass with double micrometric adjustment and position memory, primary by-pass for recirculation, thermometer 0÷80 °C for mixed water and probe pocket for mixed water. Available with or without straight or angled shut-off ball valves G 3/4”F on primary side. Available with or without 3-speed standard pump WILO3F centre distance 130 mm or variable-speed electronic pump WILO4F centre distance 130 mm. Body made of nickel-plated CB753S brass; gaskets and O-rings made of peroxide-cured EPDM; other parts made of CW617N brass. Max operating temperature 100 °C. Max operating pressure 10 bar. Max differential pressure at mixing valve ends 250 mbar. AUM 03: expanded polypropylene insulating cover. T 5011 U: thermostatic head with incorporated control and immersion remote sensor. Range 30÷55 °C o 25÷50 °C. Cable lengh 2 m. RV 01: axial servomotor M30x1.5. 3-point adjustment 230 V AC or proportional 0-10 V 24 V AC with display. AUM 01 - AUM 11 D/S: high-temperature kit for UNIMIX/UNIMIX-C with primary side connections G 1” and plain manifolds with 3 outlets (EUROK outlets). Complete with fill/drain valve and differential pressure by-pass valve 0.2÷0.6 bar. Available with or without straight or angled shut-off ball valves G 1” primary side. AUM 02 - AUM 12 D/S: high-temperature kit for UNIMIX/UNIMIX-C with primary side connections G 1” and manifolds with 3 outlets (delivery: double micrometric adjustment lockshield; return: headwork for thermostatic control with protection cap; EUROK outlets). Complete with fill/drain valve and differential pressure by-pass valve 0.2÷0.6 bar. Available with or without straight or angled shut-off ball valves G 1”F on primary side. AC 613 FU: fixed setting 60 °C safety thermostat pre-wired.

Conform cu EMCS

.RVT .RFA

Unități de control - Termice

IVAR

Descărcare
ABB Compact Distribution Boards U, UL, TU

Compact Distribution Boards U, UL, TU

Compact Distribution Boards U, UL, TU for flush and hollow wall-mounting - versions with various distribution and media panels - four different door types - suitable for CombiLine N

ABB

Compact Distribution Boards U, UL, TU

Compact Distribution Boards U, UL, TU
for flush and hollow wall-mounting
- versions with various distribution and media panels
- four different door types
- suitable for CombiLine N

Conform cu EMCS

.DWG .RFA .IFC

Cofrete electrice

ABB

Descărcare