RC-EX3D /-ZD

Remote Controller - Wired Remote Controller with Easy touch and Easy view with full dot Liquid Crystal display - LCD panel with light tap operation - Simple interface with only three buttons - Multi language display (12 languages) - New function for KXZ3 and safety equipment - Setting for KXZ3 energy saving function - Control for Thermal sensor kit (option for designated model only)

Mitsubishi Heavy Industries Air Conditioning Europe

RC-EX3D /-ZD

Remote Controller
- Wired Remote Controller with Easy touch and Easy view with full dot Liquid Crystal display
- LCD panel with light tap operation
- Simple interface with only three buttons
- Multi language display (12 languages)
- New function for KXZ3 and safety equipment
- Setting for KXZ3 energy saving function
- Control for Thermal sensor kit (option for designated model only)

EMCS compliant

.DWG .RFA .IFC

Control Unit for Heating and Cooling

Mitsubishi Heavy Industries Air Conditioning Europe

Download

RC-ES1

Design Remote Controller

Mitsubishi Heavy Industries Air Conditioning Europe

RC-ES1

Design Remote Controller

EMCS compliant

.DWG .RFA .IFC

Control Unit for Heating and Cooling

Mitsubishi Heavy Industries Air Conditioning Europe

Download

FDUM22-160KXZE3-W

VRF ducted low/middle static pressure - Indoor unit (R32) - Adjustable external static pressure by wired remote controller - Wide external static pressure: from 10 to 100 Pa - Installation flexibility as thin design with 280mm height - Standard built- in drain pump - Transparent access hole to drain pan to check the drain pan without removing drain pan - Reduced energy consumption by applying DC fan motor

Mitsubishi Heavy Industries Air Conditioning Europe

FDUM22-160KXZE3-W

VRF ducted low/middle static pressure - Indoor unit (R32)
- Adjustable external static pressure by wired remote controller
- Wide external static pressure: from 10 to 100 Pa
- Installation flexibility as thin design with 280mm height
- Standard built- in drain pump
- Transparent access hole to drain pan to check the drain pan without removing drain pan
- Reduced energy consumption by applying DC fan motor

EMCS compliant

.DWG .RFA .IFC

Air Conditioner

Mitsubishi Heavy Industries Air Conditioning Europe

Download

FDU45-280KXZE3-W

VRF ducted high static pressure - Indoor unit (R32) - Adjustable external static pressure by wired remote controller - Wide external static pressure: from 10 to 200 Pa - Standard built- in drain pump - Transparent access hole to drain pan to check the drain pan without removing drain pan - Reduced energy consumption by applying DC fan motor

Mitsubishi Heavy Industries Air Conditioning Europe

FDU45-280KXZE3-W

VRF ducted high static pressure - Indoor unit (R32)
- Adjustable external static pressure by wired remote controller
- Wide external static pressure: from 10 to 200 Pa
- Standard built- in drain pump
- Transparent access hole to drain pan to check the drain pan without removing drain pan
- Reduced energy consumption by applying DC fan motor

EMCS compliant

.DWG .RFA .IFC

Air Conditioner

Mitsubishi Heavy Industries Air Conditioning Europe

Download

FDUH22-36KXZE3-W

VRF Duct Connected-Compact & Flexible - Indoor Unit (R32) - Compact ducted unit with slim design (257mm height & 570 mm Width). - The best solution for air conditioning in hotels with compact and thin size units - Interchangeable return air inlet (bottom or front) - Low sound level: the low sound level can ensure comfortable stay and rest in hotels. - Drain pump optional.

Mitsubishi Heavy Industries Air Conditioning Europe

FDUH22-36KXZE3-W

VRF Duct Connected-Compact & Flexible - Indoor Unit (R32)
- Compact ducted unit with slim design (257mm height & 570 mm Width).
- The best solution for air conditioning in hotels with compact and thin size units
- Interchangeable return air inlet (bottom or front)
- Low sound level: the low sound level can ensure comfortable stay and rest in hotels.
- Drain pump optional.

EMCS compliant

.DWG .RFA .IFC

Air Conditioner

Mitsubishi Heavy Industries Air Conditioning Europe

Download

FDT28-160KXZE3-W

VRF ceiling cassette -4way- Indoor unit (R32) - Draft Prevention Panel as an option - Individual flap control system - Drain can be discharged upwards by 850mm from the ceiling surface. - Motion Sensor to improve the comfort and energy saving performance of the unit. - Component design can achieve better aerodynamic performance and lower noise level

Mitsubishi Heavy Industries Air Conditioning Europe

FDT28-160KXZE3-W

VRF ceiling cassette -4way- Indoor unit (R32)
- Draft Prevention Panel as an option
- Individual flap control system
- Drain can be discharged upwards by 850mm from the ceiling surface.
- Motion Sensor to improve the comfort and energy saving performance of the unit.
- Component design can achieve better aerodynamic performance and lower noise level

EMCS compliant

.DWG .RFA .IFC

Air Conditioner

Mitsubishi Heavy Industries Air Conditioning Europe

Download